Solid state relay SSR-40AA, 40A 70-280V AC to AC

$58.77
Favorable price AC to AC solid state relay (SSR), single phase, zero cross, switching load current up to 40 amp, with input voltage 70-280V AC and load voltage 24-480V AC, long service life and high quality.
SKU: ATO-SSR-DH40AA
Free Shipping
Delivery date: 6-12 days

Features

40A solid state relay (SSR) with 70-280V AC input features high structural strength, good impact resistance, and strong shock resistance. The SSR offers a reliable switching the commercial and industrial loads, such as computer peripheral interface device, printing machine, molding machine, food machine, packaging machine, and so on.

  • Built in RC absorption
  • Photoelectric isolation
  • SCR output
  • LED indicator for operation status
  • Removable protective cover for safety
  • Panel mount
  • Zero-crossing switch type

Specification

ModelATO-SSR-DH40AA
InputControl voltage range70-280V AC
Max. input current15mA
Must operate voltage70V AC
Must release voltage50V AC
OutputLoad voltage range24-480V AC
Peak voltage800V AC
Maximum load current40A
Maximum off-state leakage current2mA
Maximum off-state time10mS
Maximum on-state voltage drop1.5V
GeneralTypeAC to AC, single phase
Dimension L – W – H (mm)57.4х44.8х28
Weight135g
Dielectric strength (input to output)4000V
Dielectric strength (input, output to the base)2500V
Operating temperature-20℃~ 80℃
MountPanel
CertificationCE

Note:

  1. When the load is a resistive load, the maximum load current of the selected SSR should be 2~3 times greater than the actual load current;
  2. When the load is an inductive load, the maximum load current of the selected SSR should be more than 7~8 times the actual load current.
  3. When the maximum load current is higher than 10A, a heat sink must be installed to the solid state relay, or the SSR relay should be mounted on a metal base plate with heat dissipation effect, and the thermal grease is applied between them.

Dimension (Unit: mm)

Single Phase SSR Dimensions

Wiring Diagram

Single Phase AC to AC SSR Wiring Diagram

Tips: Installation methods of solid state relays

Horizontal W-type and vertical L-type of solid state relays in small sizes are suitable for direct welding installation on the printed circuit board (PCB). Vertical L2-type is not only suitable for welding installation on circuit board, but also can be applied to socket installation on the circuit board. In the selection of SSRs used in PCB under small current standard, welding temperature should be less than 250 ℃, and time is limited to 10s since the lead terminal is made of high thermal conductivity materials. Given the ambient temperature, derating use can be considered if necessary. The load current is generally controlled within 1/2 of the rated value.
K-type and F-type are suitable for installation on radiators and instrument baseplates. In case of high-power SSRs (K-type and F-type package) installation, it should be noted that contact surface with the radiator is smooth, and is coated with thermal grease. The larger the installation torque, the smaller the contact resistance. It is necessary to equip high-current leads with cold welding flakes to reduce contact resistance of the lead wire.

Solid state relay (SSR) is simple but widely used in the automation fields. Thus, it is not complex to wire a solid state relay. In this vedio, ATO takes a 40 Amp SSR (DC - AC) for example to show the wiring of a SSR and then switch on/off a motor with this SSR.

How to Test a Solid State Relay?

Solid state relays are commonly used to control many electronic components, so if a component isn't working because there's no current flowing through it, it's likely a problem with the relay. With some simple troubleshooting steps, it's easy to check if an SSR is working as expected. In this video, we'll show you step-by-step instructions on how to test a solid state relay.

Types of Solid State Relays

There are different types of solid state relays according to various classification standards. In this video, we will introduce a series of different types of SSRs according to the following standards.

DC-AC/AC-AC Single Phase Solid State Relays

In this video we take a quick look at ATO's current single phase SSR models along with their specifications and key features. They are designed to operate high load currents using low control currents, using our advanced opto-isolation technology.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Useful solid state relay
5
Shaun
Avatar
12/7/2022 8:32 PM
I've been using this solid state relay as part of a circuit to control some line-level baseboard heaters. No problems so far. Be sure to install the appropriate heat sink and use thermal paste.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Features

40A solid state relay (SSR) with 70-280V AC input features high structural strength, good impact resistance, and strong shock resistance. The SSR offers a reliable switching the commercial and industrial loads, such as computer peripheral interface device, printing machine, molding machine, food machine, packaging machine, and so on.

  • Built in RC absorption
  • Photoelectric isolation
  • SCR output
  • LED indicator for operation status
  • Removable protective cover for safety
  • Panel mount
  • Zero-crossing switch type

Specification

ModelATO-SSR-DH40AA
InputControl voltage range70-280V AC
Max. input current15mA
Must operate voltage70V AC
Must release voltage50V AC
OutputLoad voltage range24-480V AC
Peak voltage800V AC
Maximum load current40A
Maximum off-state leakage current2mA
Maximum off-state time10mS
Maximum on-state voltage drop1.5V
GeneralTypeAC to AC, single phase
Dimension L – W – H (mm)57.4х44.8х28
Weight135g
Dielectric strength (input to output)4000V
Dielectric strength (input, output to the base)2500V
Operating temperature-20℃~ 80℃
MountPanel
CertificationCE

Note:

  1. When the load is a resistive load, the maximum load current of the selected SSR should be 2~3 times greater than the actual load current;
  2. When the load is an inductive load, the maximum load current of the selected SSR should be more than 7~8 times the actual load current.
  3. When the maximum load current is higher than 10A, a heat sink must be installed to the solid state relay, or the SSR relay should be mounted on a metal base plate with heat dissipation effect, and the thermal grease is applied between them.

Dimension (Unit: mm)

Single Phase SSR Dimensions

Wiring Diagram

Single Phase AC to AC SSR Wiring Diagram

Tips: Installation methods of solid state relays

Horizontal W-type and vertical L-type of solid state relays in small sizes are suitable for direct welding installation on the printed circuit board (PCB). Vertical L2-type is not only suitable for welding installation on circuit board, but also can be applied to socket installation on the circuit board. In the selection of SSRs used in PCB under small current standard, welding temperature should be less than 250 ℃, and time is limited to 10s since the lead terminal is made of high thermal conductivity materials. Given the ambient temperature, derating use can be considered if necessary. The load current is generally controlled within 1/2 of the rated value.
K-type and F-type are suitable for installation on radiators and instrument baseplates. In case of high-power SSRs (K-type and F-type package) installation, it should be noted that contact surface with the radiator is smooth, and is coated with thermal grease. The larger the installation torque, the smaller the contact resistance. It is necessary to equip high-current leads with cold welding flakes to reduce contact resistance of the lead wire.

Product reviews
Useful solid state relay
5
Shaun
Avatar
12/7/2022 8:32 PM
I've been using this solid state relay as part of a circuit to control some line-level baseboard heaters. No problems so far. Be sure to install the appropriate heat sink and use thermal paste.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews