Temperature transmitter supports RTD, thermocouple, resistance and voltage input signal.
Note: If you customize the sensor input type, the USB cable needs to be purchased.
Specification:
| Model | ATO-TEMPT-ST500 |
| Accuracy | ≤0.1%FS |
| Power supply | DC 12-40V |
| Input signal* | RTD (PT100, Cu50), thermocouple (B/E/J/K/N/R/S/T), resistance, voltage (mV) |
| Output signal * | 4-20mA, 1-5V |
| Digital communication * | Hart protocol (optional) |
| Response time | ≤1s |
| Working temperature | -40~+85℃ |
| Ingress protection | 4g^2-150Hz |
| Settable parameter | Input signal, measuring range, cold junction compensation (automatic adjusting) |
| Configuration | PAD or PC |
Input signal and measuring range chart:
| Type of sensor | Measuring range | Minimum measuring range | Connection type |
| PT100 | -200~+850℃ | 10K | 3-wire |
| Cu50 | -50~+150℃ | 10K | 3-wire |
| B | 400~+1820℃ | 500K | 2-wire |
| E | -100~+1000℃ | 50K | 2-wire |
| J | -100~+1200℃ | 50K | 2-wire |
| K | -180~+1372℃ | 50K | 2-wire |
| N | -180~+1300℃ | 50K | 2-wire |
| R | -50~+1760℃ | 500K | 2-wire |
| S | -500~+1760℃ | 500K | 2-wire |
| T | -200~+400℃ | 50K | 2-wire |
| Resistance transmitter | 0~4500Ω | 10Ω | 2-wire |
Dimensional drawing (unit: mm):
Installation diagram:
Wiring diagram:
Tips: Common faults for a temperature transmitter
- There's no change at the transmitter output when the temperature of the measured medium increases or decreases. This is mostly caused by the seal of the temperature transmitter, perhaps the temperature transmitter is not sealed well, or when it is welded, a small hole is bored on the sensor accidentally. In this case, the solution is to replace the transmitter shell.
- The output signal is instable. This may be caused by the temperature source itself. The temperature source doesn't have stable temperature. If the instrument can't display stably, then it doesn't have enough anti-interference ability.
- Output error of the temperature transmitter is large. Many reasons may cause this problem, such as the thermal resistance wire of the selected temperature transmitter is incorrect, thus leading to measuring range error. Or the temperature transmitter is not correctly calibrated when it left the factory.
Product reviews
4-20mA temperature transmitter
Simon
10/10/2018 9:05 PM
By consulting, the temperature transmitter and Pt100 RTD sensor should be used together, so we purchased them together. We chose the 4-20mA output temperature transmitter. The smart transmitter could directly convert temperature signal into current signal and record it. That's what we want.
Was this review helpful? (0/0)
Precise Transmitter
Jimmyy
6/16/2024 8:49 PM
Our school's kitchen and storage room need this smart temperature transmitter to detect the indoor temperature more accurately. Considering the installation problem, I am a little worried about the USB cable.
Was this review helpful? (0/0)
Clever Temperature Transmitter
Erickaa
6/16/2024 9:06 PM
We have a requirement to read RPM from this smart temperature transmitter. The manual is not clear on how to read the output from the drive to get a usable signal that can represent the motor rpm. Where I can get more information on how to read an output from the controller to get us to a motor RPM,?