Hydraulic Pressure Switch, 0.2 to 400 Bar, 1NO+1NC

$107.14
Cost-effective hydraulic pressure switch with optional 0.2-1 bar/ 1-5 bar/ 1-10 bar/ 10-20 bar/ 20-50 bar/ 50-150 bar/ 100-200 bar/ 200-400 bar pressure range, four connection threads can be chosen, 250VAC/ 24VDC max voltage, 4A max current. The electric pressure switch has the advantages of flexible installation, convenient use, strong independence and long service life.
SKU: ATO-HPS-LF727
*
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

Lower price air pressure switch with 1NO+1NC contact form, 150 bar max working pressure, 600 bar burst pressure. The hydraulic pressure switch is widely used in hydraulic systems, engineering equipment, gas pumping station and automatic mechanical equipment.

Specification

ModelATO-PS-LF727
Pressure range0.2-1 bar/ 1-5 bar/ 1-10 bar/ 10-20 bar/ 20-50 bar/ 50-150 bar/ 100-200 bar/ 200-400 bar
Connection thread1/8 NPT, 1/4 NPT, G1/8, G1/4
Body materialZinc-plated steel/ stainless steel
Contact form1NO+1NC
Max voltage250VAC/ 24VDC
Max current4A
Life endurance10⁶
Eletrical life endurance10⁵
Poluution situationNormal
IP levelIP65
Max working pressure150 bar
Burst pressure600 bar
CertificateCE, RoHS, REACH
Warranty12 months

Dimensions (mm)

Dimension of pressure switch

Tips: Precautions of Using Pressure Switch.

Pressure switches are widely used in the high and low pressure protection control of household, commercial, and automobile refrigeration systems, steam conditions and power stations; accumulators, receivers, flash tanks, separators, scrubbers, oil refining devices. It can also be applied to the high and low pressure protection control of various equipment and tools. But in the selection of pressure switch, the following points must be paid attention to:
1. The necessity of explosion-proof: explosion-proof forms are divided into explosion-proof type and intrinsically safe type, and most of Nagano products are explosion-proof type.
2. Whether you need to bring instructions: according to customer instructions.
3. Number of contacts: one contact (one output) or two contacts (two outputs).
4. Determination of setting value and pressure range: The recommended setting range is between 30% and 65% of the pressure range, and the setting range is between 15% and 90% of the pressure range.
5. The form of differential connection: adjustable or fixed.
6. Whether there is pulsation: If the pressure is pulsating or vibrating, a throttle valve is required to suppress the damage of the pulsating pressure to the instrument.
7. The occasion with diaphragm: when measuring corrosiveness, high viscosity or high temperature, it is necessary to select a diaphragm.

Product reviews
Pressure switch specifications
5
Bethel
Avatar
7/17/2026 12:37 AM
Which specific model corresponds to the following specifications: pressure range 200–400 bar, G1/4 interface, galvanized steel construction, NBR diaphragm, plug-in terminal wiring, and pressure rise action?
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-PS-LF727 pressure switch is configurable for a pressure range of 200–400 bar. What is your specific operating pressure?
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Lower price air pressure switch with 1NO+1NC contact form, 150 bar max working pressure, 600 bar burst pressure. The hydraulic pressure switch is widely used in hydraulic systems, engineering equipment, gas pumping station and automatic mechanical equipment.

Specification

ModelATO-PS-LF727
Pressure range0.2-1 bar/ 1-5 bar/ 1-10 bar/ 10-20 bar/ 20-50 bar/ 50-150 bar/ 100-200 bar/ 200-400 bar
Connection thread1/8 NPT, 1/4 NPT, G1/8, G1/4
Body materialZinc-plated steel/ stainless steel
Contact form1NO+1NC
Max voltage250VAC/ 24VDC
Max current4A
Life endurance10⁶
Eletrical life endurance10⁵
Poluution situationNormal
IP levelIP65
Max working pressure150 bar
Burst pressure600 bar
CertificateCE, RoHS, REACH
Warranty12 months

Dimensions (mm)

Dimension of pressure switch

Tips: Precautions of Using Pressure Switch.

Pressure switches are widely used in the high and low pressure protection control of household, commercial, and automobile refrigeration systems, steam conditions and power stations; accumulators, receivers, flash tanks, separators, scrubbers, oil refining devices. It can also be applied to the high and low pressure protection control of various equipment and tools. But in the selection of pressure switch, the following points must be paid attention to:
1. The necessity of explosion-proof: explosion-proof forms are divided into explosion-proof type and intrinsically safe type, and most of Nagano products are explosion-proof type.
2. Whether you need to bring instructions: according to customer instructions.
3. Number of contacts: one contact (one output) or two contacts (two outputs).
4. Determination of setting value and pressure range: The recommended setting range is between 30% and 65% of the pressure range, and the setting range is between 15% and 90% of the pressure range.
5. The form of differential connection: adjustable or fixed.
6. Whether there is pulsation: If the pressure is pulsating or vibrating, a throttle valve is required to suppress the damage of the pulsating pressure to the instrument.
7. The occasion with diaphragm: when measuring corrosiveness, high viscosity or high temperature, it is necessary to select a diaphragm.

Product reviews
Pressure switch specifications
5
Bethel
Avatar
7/17/2026 12:37 AM
Which specific model corresponds to the following specifications: pressure range 200–400 bar, G1/4 interface, galvanized steel construction, NBR diaphragm, plug-in terminal wiring, and pressure rise action?
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-PS-LF727 pressure switch is configurable for a pressure range of 200–400 bar. What is your specific operating pressure?
Only registered users can write reviews