Brazed Plate Air to Air Heat Exchanger, 150 Plate

$839.23
Brazed plate heat exchanger for sale. Maximum quantity of plates is 150. Heat exchange capacity is 17k~51kBTU/10k~102kBTU/34k~240kBTU/68k~320kBTU for specific models. Heat exchanging mediums include air to air, water to water, water to air, air to water, oil to water, etc. Brazed plate heat exchanger is non-standard product, specific plate quantity and heat exchange capacity are customizable.
SKU: ATO-PHE-150
*
Free Shipping
Delivery date: 6-12 days

Medium flow direction is counter flow (the primary and secondary flow direction is parallel and opposite).

Application: Brazed plate heat exchanger can be used in low temperature test equipment, refrigeration equipment, chiller, air conditioner, oil cooling, laser equipment, solar equipment, heat pump units, heating water heaters and other fields. Channel type combinations and distributor configurations are also available for selection or customization.

Note: Non-standard customized products, for different plate quantities, price is different, the page price is for reference only. Please contact us for specific price.

Specification

ModelATO-PHE-028ATO-PHE-030ATO-PHE-052ATO-PHE-060
Max Quantity of Plates150150150150
Heat Exchange CapacityBTU17k~51k10k~102k34k~240k68k~320k
Heat Exchange CapacityW5k~15k3k~30k10k~70k20k~95k
Heat Exchange Area/Per Plate0.028m20.030m20.052m20.060m2
Volume/Per Channel0.05L0.028L0.094L0.111L
Plate Thickness0.4mm0.3mm0.4mm0.3mm
Max Flow5.0 m3/h8.0 m3/h18 m3/h22 m3/h
Channel*H, L, MHH, L, MH
Designed Pressure3.0/4.0 MPa3.0/4.5 MPa3.0/4.5 MPa3.0/4.5 MPa
Size311*111mm325*95mm527*111mm527*120mm
Weight (kg, n is the plates quantity)1.2+0.1n1+0.09n1.8+0.23n2.4+0.195n
Liquid Side Maximum Threaded1"1/41"1"1/41"1/4
Fluorine Side Maximum Thread1"3/81"1/81"3/81"3/8
Distributor-HQHQ, LQ, MQHQ
Medium Flow Directioncounter flow
CertificationCE
Designed Temperature-196℃~+200℃

*Channel Form Characteristics

L channel: low heat transfer coefficient, low resistance, suitable for large flow rate and weak heat transfer (low specific heat or small temperature difference), such as air heat transfer under ambient pressure.

H channel: high heat transfer coefficient, high resistance, suitable for small flow rate and strong heat transfer (high specific heat, with phase change or large temperature difference), such as refrigerant phase change heat transfer.

M channel: heat transfer coefficient and resistance are between H channel and L channel.

Dimension Diagram of 150 Plate Brazed Plate Heat Exchanger (unit: mm)

Calculation method of size A
ModelATO-PHE-028ATO-PHE-030ATO-PHE-052ATO-PHE-060
A (mm)11+2.3n11+1.55n11+2.4n11+2.3n
A (mm)9+2.3n9+1.55n9+2.4n9+2.3n

Dimension Diagram of Plate Heat Exchanger Model 28

Dimension Diagram of Plate Heat Exchanger Model 52/60

Tips: Structure of the brazed plate heat exchanger.

  • Brazed plate heat exchanger consists of a group of plates (the adjacent plates form an angle of 180 ° with each other) superpose in order, form a plate package with channel form.
  • Both ends of the heat exchanger are respectively provided with a sealing plate with pipe.
  • The whole plate heat exchanger is made by vacuum brazing.
  • Adjacent channels respectively flow two medium.
  • Plates between adjacent channels are pressed into corrugated pattern to strengthen heat exchange between the two medium.
  • In refrigeration BPHE, water channel is always one more than refrigerant channel.

Structure Drawing of Brazed Plate Air to Air Heat Exchanger

Joint Identification Diagram

Joint Identification Diagram of Brazed Plate Heat Exchanger

Plate Assembly Diagram

Plate Assembly Diagram of Brazed Plate Heat Exchanger

Flow and Channel Diagram

Flow and Channel Diagram of Brazed Plate Heat Exchanger

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
High heat exchange efficiency
5
Edward
Avatar
4/19/2020 7:51 PM
I use this heat exchanger for HVAC systems. By customizing the number of plates and power, its heat exchange efficiency reaches the specifications I need. Its volume is not too large, saving installation space. Material of the heat exchanger has good corrosion resistance and can operate efficiently under high temperature and high pressure environments.
Was this review helpful? Yes No (0/0)
Perfect heat exchanger
5
Paulo
Avatar
5/22/2022 9:38 PM
I flushed the heat exchanger out with acetone before I installed it to ensure that there was no debris or metal particles in it, and it was perfectly clean. Definitely recommend!
Was this review helpful? Yes No (0/0)
Plate heat exchanger
5
Finley
Avatar
4/20/2025 8:45 PM
Hello, can you provide a plate heat exchanger for a 500 liter milk batch? For pasteurization and cooling purposes.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we do not provide heat exchangers for pasteurization and cooling of milk.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Medium flow direction is counter flow (the primary and secondary flow direction is parallel and opposite).

Application: Brazed plate heat exchanger can be used in low temperature test equipment, refrigeration equipment, chiller, air conditioner, oil cooling, laser equipment, solar equipment, heat pump units, heating water heaters and other fields. Channel type combinations and distributor configurations are also available for selection or customization.

Note: Non-standard customized products, for different plate quantities, price is different, the page price is for reference only. Please contact us for specific price.

Specification

ModelATO-PHE-028ATO-PHE-030ATO-PHE-052ATO-PHE-060
Max Quantity of Plates150150150150
Heat Exchange CapacityBTU17k~51k10k~102k34k~240k68k~320k
Heat Exchange CapacityW5k~15k3k~30k10k~70k20k~95k
Heat Exchange Area/Per Plate0.028m20.030m20.052m20.060m2
Volume/Per Channel0.05L0.028L0.094L0.111L
Plate Thickness0.4mm0.3mm0.4mm0.3mm
Max Flow5.0 m3/h8.0 m3/h18 m3/h22 m3/h
Channel*H, L, MHH, L, MH
Designed Pressure3.0/4.0 MPa3.0/4.5 MPa3.0/4.5 MPa3.0/4.5 MPa
Size311*111mm325*95mm527*111mm527*120mm
Weight (kg, n is the plates quantity)1.2+0.1n1+0.09n1.8+0.23n2.4+0.195n
Liquid Side Maximum Threaded1"1/41"1"1/41"1/4
Fluorine Side Maximum Thread1"3/81"1/81"3/81"3/8
Distributor-HQHQ, LQ, MQHQ
Medium Flow Directioncounter flow
CertificationCE
Designed Temperature-196℃~+200℃

*Channel Form Characteristics

L channel: low heat transfer coefficient, low resistance, suitable for large flow rate and weak heat transfer (low specific heat or small temperature difference), such as air heat transfer under ambient pressure.

H channel: high heat transfer coefficient, high resistance, suitable for small flow rate and strong heat transfer (high specific heat, with phase change or large temperature difference), such as refrigerant phase change heat transfer.

M channel: heat transfer coefficient and resistance are between H channel and L channel.

Dimension Diagram of 150 Plate Brazed Plate Heat Exchanger (unit: mm)

Calculation method of size A
ModelATO-PHE-028ATO-PHE-030ATO-PHE-052ATO-PHE-060
A (mm)11+2.3n11+1.55n11+2.4n11+2.3n
A (mm)9+2.3n9+1.55n9+2.4n9+2.3n

Dimension Diagram of Plate Heat Exchanger Model 28

Dimension Diagram of Plate Heat Exchanger Model 52/60

Tips: Structure of the brazed plate heat exchanger.

  • Brazed plate heat exchanger consists of a group of plates (the adjacent plates form an angle of 180 ° with each other) superpose in order, form a plate package with channel form.
  • Both ends of the heat exchanger are respectively provided with a sealing plate with pipe.
  • The whole plate heat exchanger is made by vacuum brazing.
  • Adjacent channels respectively flow two medium.
  • Plates between adjacent channels are pressed into corrugated pattern to strengthen heat exchange between the two medium.
  • In refrigeration BPHE, water channel is always one more than refrigerant channel.

Structure Drawing of Brazed Plate Air to Air Heat Exchanger

Product reviews
High heat exchange efficiency
5
Edward
Avatar
4/19/2020 7:51 PM
I use this heat exchanger for HVAC systems. By customizing the number of plates and power, its heat exchange efficiency reaches the specifications I need. Its volume is not too large, saving installation space. Material of the heat exchanger has good corrosion resistance and can operate efficiently under high temperature and high pressure environments.
Was this review helpful? Yes No (0/0)
Perfect heat exchanger
5
Paulo
Avatar
5/22/2022 9:38 PM
I flushed the heat exchanger out with acetone before I installed it to ensure that there was no debris or metal particles in it, and it was perfectly clean. Definitely recommend!
Was this review helpful? Yes No (0/0)
Plate heat exchanger
5
Finley
Avatar
4/20/2025 8:45 PM
Hello, can you provide a plate heat exchanger for a 500 liter milk batch? For pasteurization and cooling purposes.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we do not provide heat exchangers for pasteurization and cooling of milk.