Cross Flow Brazed Plate Heat Exchanger

$406.77
Cross flow brazed plate heat exchanger price is affordable. Maximum quantity of plates is 50/198/250 for different models, heat exchange capacity is 17kBTU/205k~680kBTU/510k~1500kBTU respectively. The product is non-standard, plate specific quantity can be customized. Applicable mediums include water to water, air to air, water to air, air to water, oil to water, etc.
SKU: ATO-PHE-1421
*
Free Shipping
Delivery date: 6-12 days

Features

  • Medium flow direction is cross flow (entrance and exit directions of the primary and secondary sides cross in and out).
  • Heat exchanger is made by vacuum brazing, there are copper brazing, nickel brazing, etc. It is the best choice for condenser and evaporator.
  • The plates are completely vacuum brazed without gasket sealing, and can withstand maximum high pressure of 6.75Mpa and high temperature of 200℃.
  • Suitable medium includes water, steam, oil, organic solvent, gas, various refrigerants (except copper-based brazed ammonia, chlorine refrigerant), etc.

Note: Non-standard customized products, for different plate quantities, price is different, the page price is for reference only. Please contact us for specific price.

Specification

ModelATO-PHE-014BATO-PHE-110ATO-PHE-210HDQ
Max Quantity of Plates50198250
Heat Exchange CapacityBTU17k205k~680k510k~1500k
W5k60k-200k150k-450k
Heat Exchange Area/Per Plate0.014m20.110m20.210m2
Volume/Per Channel0.22L0.16L0.40L
Plate Thickness0.3mm0.4mm0.4mm
Max Flow4.0m3/h62m3/h105m3/h
Channel*HHH
Designed Pressure1.0/3.0MPa3.0/4.5MPa2.5MPa
Size193*83mm490*250mm739*322mm
Weight (kg, n is the plates quantity)0.4+0.05n6.5+0.42n13+0.82n
Liquid Side Maximum Threaded3/4"2"1/24"
Fluorine Side Maximum Thread7/8"2"1/83"1/8
Distributor-HQ, HDQHDQ
Additional Attributes--Dual circuit system
Medium Flow Directioncounter flow
CertificationCE
Designed Temperature-196℃~+200℃

*Channel Form Characteristics

L channel: low heat transfer coefficient, low resistance, suitable for large flow rate and weak heat transfer (low specific heat or small temperature difference), such as air heat transfer under ambient pressure.

H channel: high heat transfer coefficient, high resistance, suitable for small flow rate and strong heat transfer (high specific heat, with phase change or large temperature difference), such as refrigerant phase change heat transfer.

M channel: heat transfer coefficient and resistance are between H channel and L channel.

Dimension Drawing of Cross Flow Brazed Plate Heat Exchanger

Calculation method of size A
ModelATO-PHE-014BATO-PHE-110ATO-PHE-210HDQ
A (mm)11+2.3n15+2.3n17+2.85n
A (mm)9+2.3n11+2.3n13+2.85n

ATO-PHE-014B heat exchanger dimension

Cross flow brazed plate heat exchanger dimension

Tips: Selection for brazed plate heat exchanger.

  1. The control specifications of the brazed plate heat exchanger selection are the heat exchanger material, working pressure, design temperature, etc.
  2. When selecting a brazed plate heat exchanger, the side with small heat transfer coefficient should get large flow speed as much as possible. Try to make the heat transfer coefficients on both sides of the two fluid heat exchange surfaces equal or similar, and increase the heat transfer coefficient. The temperature of the fluid heated by heat exchanger should be 10℃ lower than the saturation temperature at the outlet pressure of the heat exchanger, and should be lower than the operating temperature of water pump used for the secondary water.
  3. Fluid containing silt or other dirt is preferably filtered before entering the cross flow heat exchanger.
  4. Flow velocity at the port of the fluid with smaller temperature difference should not be too large, and it should be able to meet the requirements of pressure drop.
  5. For the condition with large flow and small allowable pressure drop, select the plate type with small resistance. Conversely, select the plate type with large resistance.
  6. According to pressure and temperature of the fluid, select a detachable or welded heat exchanger.
  7. It is not advisable to select plates with too small single plate area, so as to avoid too many plates of the heat exchanger, resulting in small flow velocity between plates and lowering the heat transfer coefficient.

Joint Identification Diagram

Joint Identification Diagram of Brazed Plate Heat Exchanger

Plate Assembly Diagram

Plate Assembly Diagram of Brazed Plate Heat Exchanger

Flow and Channel Diagram

Flow and Channel Diagram of Brazed Plate Heat Exchanger

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Great brazed plate heat exchanger
5
Susanh
Avatar
9/15/2021 12:15 AM
I put this brazed plate heat exchanger on my car to use as an engine oil cooler and it is working great. I am running the oil through one side of this brazed plate heat exchanger and coolant through the other side. So far so good, the oil temp is staying within a couple of degrees of coolant temp and there are no leaks, so I am very pleased.
Was this review helpful? Yes No (0/0)
Capacity of heat exchanger
5
Dgregor
Avatar
12/24/2021 12:31 AM
What is the exact heat exchange capacity for a 100-plate ATO-PHE-110? I only see a range of 60k-200k on the website since the number of plates is only given a max.
Was this review helpful? Yes No (0/0)
ATO Responded
It depends on the specific working condition, the inlet and outlet temperature is different, which will affect the heat transfer.
Great heat exchanger
5
Dolly
Avatar
4/20/2022 9:51 PM
I put this heat exchanger on my car to use as an engine oil cooler and it is working great so far. I would order this again if I need more.
Was this review helpful? Yes No (0/0)
So far so good
5
Beeyh
Avatar
4/25/2022 7:27 PM
I am running the oil through one side of this heat exchanger and coolant through the other side. The oil temp is staying within a couple of degrees of coolant temp and there are no leaks, so I'm very pleased.
Was this review helpful? Yes No (0/0)
Well worth the money
5
Paulo
Avatar
6/13/2022 7:20 PM
The heat exchanger is easy to install. Our hot water heater has not used any electricity since the heat exchanger has been installed. Well worth the money.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Features

  • Medium flow direction is cross flow (entrance and exit directions of the primary and secondary sides cross in and out).
  • Heat exchanger is made by vacuum brazing, there are copper brazing, nickel brazing, etc. It is the best choice for condenser and evaporator.
  • The plates are completely vacuum brazed without gasket sealing, and can withstand maximum high pressure of 6.75Mpa and high temperature of 200℃.
  • Suitable medium includes water, steam, oil, organic solvent, gas, various refrigerants (except copper-based brazed ammonia, chlorine refrigerant), etc.

Note: Non-standard customized products, for different plate quantities, price is different, the page price is for reference only. Please contact us for specific price.

Specification

ModelATO-PHE-014BATO-PHE-110ATO-PHE-210HDQ
Max Quantity of Plates50198250
Heat Exchange CapacityBTU17k205k~680k510k~1500k
W5k60k-200k150k-450k
Heat Exchange Area/Per Plate0.014m20.110m20.210m2
Volume/Per Channel0.22L0.16L0.40L
Plate Thickness0.3mm0.4mm0.4mm
Max Flow4.0m3/h62m3/h105m3/h
Channel*HHH
Designed Pressure1.0/3.0MPa3.0/4.5MPa2.5MPa
Size193*83mm490*250mm739*322mm
Weight (kg, n is the plates quantity)0.4+0.05n6.5+0.42n13+0.82n
Liquid Side Maximum Threaded3/4"2"1/24"
Fluorine Side Maximum Thread7/8"2"1/83"1/8
Distributor-HQ, HDQHDQ
Additional Attributes--Dual circuit system
Medium Flow Directioncounter flow
CertificationCE
Designed Temperature-196℃~+200℃

*Channel Form Characteristics

L channel: low heat transfer coefficient, low resistance, suitable for large flow rate and weak heat transfer (low specific heat or small temperature difference), such as air heat transfer under ambient pressure.

H channel: high heat transfer coefficient, high resistance, suitable for small flow rate and strong heat transfer (high specific heat, with phase change or large temperature difference), such as refrigerant phase change heat transfer.

M channel: heat transfer coefficient and resistance are between H channel and L channel.

Dimension Drawing of Cross Flow Brazed Plate Heat Exchanger

Calculation method of size A
ModelATO-PHE-014BATO-PHE-110ATO-PHE-210HDQ
A (mm)11+2.3n15+2.3n17+2.85n
A (mm)9+2.3n11+2.3n13+2.85n

ATO-PHE-014B heat exchanger dimension

Cross flow brazed plate heat exchanger dimension

Tips: Selection for brazed plate heat exchanger.

  1. The control specifications of the brazed plate heat exchanger selection are the heat exchanger material, working pressure, design temperature, etc.
  2. When selecting a brazed plate heat exchanger, the side with small heat transfer coefficient should get large flow speed as much as possible. Try to make the heat transfer coefficients on both sides of the two fluid heat exchange surfaces equal or similar, and increase the heat transfer coefficient. The temperature of the fluid heated by heat exchanger should be 10℃ lower than the saturation temperature at the outlet pressure of the heat exchanger, and should be lower than the operating temperature of water pump used for the secondary water.
  3. Fluid containing silt or other dirt is preferably filtered before entering the cross flow heat exchanger.
  4. Flow velocity at the port of the fluid with smaller temperature difference should not be too large, and it should be able to meet the requirements of pressure drop.
  5. For the condition with large flow and small allowable pressure drop, select the plate type with small resistance. Conversely, select the plate type with large resistance.
  6. According to pressure and temperature of the fluid, select a detachable or welded heat exchanger.
  7. It is not advisable to select plates with too small single plate area, so as to avoid too many plates of the heat exchanger, resulting in small flow velocity between plates and lowering the heat transfer coefficient.
Product reviews
Great brazed plate heat exchanger
5
Susanh
Avatar
9/15/2021 12:15 AM
I put this brazed plate heat exchanger on my car to use as an engine oil cooler and it is working great. I am running the oil through one side of this brazed plate heat exchanger and coolant through the other side. So far so good, the oil temp is staying within a couple of degrees of coolant temp and there are no leaks, so I am very pleased.
Was this review helpful? Yes No (0/0)
Capacity of heat exchanger
5
Dgregor
Avatar
12/24/2021 12:31 AM
What is the exact heat exchange capacity for a 100-plate ATO-PHE-110? I only see a range of 60k-200k on the website since the number of plates is only given a max.
Was this review helpful? Yes No (0/0)
ATO Responded
It depends on the specific working condition, the inlet and outlet temperature is different, which will affect the heat transfer.
Great heat exchanger
5
Dolly
Avatar
4/20/2022 9:51 PM
I put this heat exchanger on my car to use as an engine oil cooler and it is working great so far. I would order this again if I need more.
Was this review helpful? Yes No (0/0)
So far so good
5
Beeyh
Avatar
4/25/2022 7:27 PM
I am running the oil through one side of this heat exchanger and coolant through the other side. The oil temp is staying within a couple of degrees of coolant temp and there are no leaks, so I'm very pleased.
Was this review helpful? Yes No (0/0)
Well worth the money
5
Paulo
Avatar
6/13/2022 7:20 PM
The heat exchanger is easy to install. Our hot water heater has not used any electricity since the heat exchanger has been installed. Well worth the money.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews