Explosion-Proof Multi Gas Detector, 5-Gas, CO, H2S, O2, LEL, VOC

$2,853.49
Favorable price portable gas detector can detect 5 gases at the same time, including CO, H2S, O2, LEL, VOC. CE, ATEX, explosion-proof certificates, selectable VOC measuring range of 0 to 100 ppm, 0 to 500 ppm, 0 to 1000 ppm, 0 to 5000 ppm, fast response and accurate detection.
SKU: GD400-5GAS
*
*
Free Shipping
Delivery date: 8-12 days

High performance handheld gas detector is a suction and diffusion dual-purpose device. When the air pump fails or in special emergency situation, it can automatically switch to the diffusion sampling method, thereby improving the protection to a new level.

Functions

  • The portable gas detector can effectively resist a three-meter drop, has passed the EMC anti-static interference test and can work normally in the walkie-talkie environment.
  • Password protection function prevents non-operators from modifying menu parameters. With safety reminder function, sound and light vibration alarm function, let operators work without worries. The high and low alarm latched function allows the operator to better capture the sudden change of the gas concentration value.
  • Real-time value, TWA, STEL, MAX, MIN multiple numerical display, and the screen can be automatically turned 180 degrees, which is convenient for viewing in special operating environments.
  • Built-in powerful sampling pump, fast detection speed. It can be connected 20m sampling tube externally, which is convenient for long-distance or confined space detection.
  • Pump suction and diffusion dual use, to provide operators with more reliable protection. With a water trap filter, it can effectively filter water, oil, dust and other impurities. It can also be used in harsh industrial environments such as coal mines and petroleum fields.
  • Beautiful and friendly user interface, reasonable and easy-to-use interactive mode. Standard storage function, one-click data export, convenient for users to analyze.
  • Unique modifiable ID identification function, convenient for users to allocate and manage the instrument. A full range of automatic detection functions, automatic prompts for voltage, pump failure alarms, etc., more comfortable to use.
  • One-key open storage, automatic image flip. It supports each channel sensor to restore the factory setting separately and multi-language including English, Chinese and etc.

Specification

ModelGD400-5GAS
Sampling MethodPump suction & diffusion dual-use type
Gas TypeCO, H2S, O2, LEL, VOC
Measuring RangeO2: 0-30% VOL, EX: 0-100% LEL, CO: 0-1000ppm, H2S: 0-100ppm, VOC: 0-100ppm, 0-200ppm, 0-500ppm, 0-1000ppm, 0-2000ppm, 0-5000ppm
ResolutionPlease contact us before placing an order.
Response Time≤30 seconds
Precision≤±2%F.S except for special gases
LanguageChinese/English (More language can be customized)
Automatically Test and Calibrate After Power-onIncluding reset, maximum value (MAX), minimum value (MIN), STEL, TWA value
UnitPPM and mg/m3 can be switched and displayed by one key, and the concentration value is automatically converted by the system
DisplayMonochrome graphics (160 x 96), the screen can be automatically flipped
BacklightThe backlight time can be manually set and will be turned on automatically when an alarm is issued.
Data RecordCan store 100,000 sets of data, the storage interval is adjustable from 5 to 3600 seconds, data can be exported, with a data cable.
Alarm95dB buzzer (@30cm), vibration alarm and flashing red LED and alarm
status indication on the screen, alarm latched; diagnostic alarm and battery undervoltage alarm, pump block alarm; man down alarm, with early warning and optional real-time remote Bluetooth notification function
Battery3.7V rechargeable lithium battery, battery capacity 2200mA
Working HoursMore than 15 hours in continuous pumping mode
ChargerTravel charger with DC interface, charging time ≥ 4 hours
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Certification (EU regulations)CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Protection GradeIP67
Working Temperature-20℃~+50℃
Humidity0~90%RH (no condensation)
Environmental Pressure86~106Kpa
Size157*84.5*59.5mm (including the back clip/water trap filter) (length * width * height)
Weight365g (including battery, belt clip and filter)
Package Included1 piece Gas detector, 1 piece 12V/1A DC power adapter, 1 piece USB cable, 1 piece User manual, 1 piece Warranty card, 1 piece Filter, 1 piece Aluminum suitcase

Note 1:

  • If you require a gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.


Details

Explosion Proof Multi Gas Detector Details

Applications

Applications of Portable Multi Gas Detector

Tips: How to maintain portable gas detector?

  • Check the gas flow rate, usually 30/h. Excessive or too small flow will have a greater impact on the analyzer results.
  • Replace the filter paper: stop the air pump and drain the filter tank.
  • Check whether there is any air leakage in the gas system. Whether the diaphragm of the sobbing pump is damaged, whether the sealing ring of the sampling probe is broken, whether the four-way valve and condensate are damaged, etc.
  • Cleaning the sampling probe and dredging the sampling hole pipeline
  • Check whether the condenser is working normally, usually the temperature is adjusted within 3℃.
  • Check the measuring device room to see if it is dirty, and clean it in time.

Different Types of Gas Detectors

Gas detectors can come in a variety of forms to meet the unique needs of different gas monitoring applications. In this video, the different types of gas detectors on the market will be explored based on various criteria to help you choose the option that best suits your specific needs.

About the Setup of Explosion Proof Portable Gas Detectors

This video is another introductory user guide for the ATO explosion proof portable gas detector series. Today we're going to do a manual operation and calibration of it. So this machine is very easy to use. There are only three buttons on it. With these three buttons, you can do all sorts of things.

How to Use a Gas Detector to Test for Leaking Gas?

In this video, it is shown how to use a combustible gas leak detector to perform a butane leak detection test.

Explosion-Proof Gas Detector User Manual

Product reviews
Thanks for your advice
5
Skluk
Avatar
10/24/2021 7:59 PM
Thank you for providing the following information and suggestions. We will order the second explosion-proof multi-gas detector.
Was this review helpful? Yes No (0/0)
When should I calibrate your gas detector?
5
Curtise
Avatar
1/25/2022 7:59 PM
When should I calibrate your gas detector?
Was this review helpful? Yes No (0/0)
ATO Responded
Gas detector typically calibrated once a year, if used frequently, then it should be half a year.
The measured data is accurate
5
Adcock
Avatar
7/26/2022 1:40 AM
I bought this gas detector for use near my food processing plant and the measurements are accurate every time. I will buy this gas detector again.
Was this review helpful? Yes No (0/0)
How to detect H2?
5
Gray
Avatar
9/9/2022 2:50 AM
I want to know how to use this instrument to detect H2 accurately and can it detect H2 in N2 background gas without O2?
Was this review helpful? Yes No (0/0)
ATO Responded
The background gas requirement for this meter to accurately detect H2 is air. It can detect H2 in an N2 background gas without O2, but the continuous time for detection should Not exceed 10 minutes. Besides, our H2 sensor only can stand pressure 1bar ±10%.
Detect hydrogen.
5
Gray
Avatar
9/9/2022 2:55 AM
Can I test hydrogen continuously for 96 hours at a pump rate of 1?
Was this review helpful? Yes No (0/0)
ATO Responded
The sensor is based on electro-chemical principles. The background gas must contain oxygen to detect, and the concentration of oxygen and hydrogen must be 1:1. You can detect hydrogen below 10000ppm as long as the oxygen concentration is not lower than 1% VOL.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High performance handheld gas detector is a suction and diffusion dual-purpose device. When the air pump fails or in special emergency situation, it can automatically switch to the diffusion sampling method, thereby improving the protection to a new level.

Functions

  • The portable gas detector can effectively resist a three-meter drop, has passed the EMC anti-static interference test and can work normally in the walkie-talkie environment.
  • Password protection function prevents non-operators from modifying menu parameters. With safety reminder function, sound and light vibration alarm function, let operators work without worries. The high and low alarm latched function allows the operator to better capture the sudden change of the gas concentration value.
  • Real-time value, TWA, STEL, MAX, MIN multiple numerical display, and the screen can be automatically turned 180 degrees, which is convenient for viewing in special operating environments.
  • Built-in powerful sampling pump, fast detection speed. It can be connected 20m sampling tube externally, which is convenient for long-distance or confined space detection.
  • Pump suction and diffusion dual use, to provide operators with more reliable protection. With a water trap filter, it can effectively filter water, oil, dust and other impurities. It can also be used in harsh industrial environments such as coal mines and petroleum fields.
  • Beautiful and friendly user interface, reasonable and easy-to-use interactive mode. Standard storage function, one-click data export, convenient for users to analyze.
  • Unique modifiable ID identification function, convenient for users to allocate and manage the instrument. A full range of automatic detection functions, automatic prompts for voltage, pump failure alarms, etc., more comfortable to use.
  • One-key open storage, automatic image flip. It supports each channel sensor to restore the factory setting separately and multi-language including English, Chinese and etc.

Specification

ModelGD400-5GAS
Sampling MethodPump suction & diffusion dual-use type
Gas TypeCO, H2S, O2, LEL, VOC
Measuring RangeO2: 0-30% VOL, EX: 0-100% LEL, CO: 0-1000ppm, H2S: 0-100ppm, VOC: 0-100ppm, 0-200ppm, 0-500ppm, 0-1000ppm, 0-2000ppm, 0-5000ppm
ResolutionPlease contact us before placing an order.
Response Time≤30 seconds
Precision≤±2%F.S except for special gases
LanguageChinese/English (More language can be customized)
Automatically Test and Calibrate After Power-onIncluding reset, maximum value (MAX), minimum value (MIN), STEL, TWA value
UnitPPM and mg/m3 can be switched and displayed by one key, and the concentration value is automatically converted by the system
DisplayMonochrome graphics (160 x 96), the screen can be automatically flipped
BacklightThe backlight time can be manually set and will be turned on automatically when an alarm is issued.
Data RecordCan store 100,000 sets of data, the storage interval is adjustable from 5 to 3600 seconds, data can be exported, with a data cable.
Alarm95dB buzzer (@30cm), vibration alarm and flashing red LED and alarm
status indication on the screen, alarm latched; diagnostic alarm and battery undervoltage alarm, pump block alarm; man down alarm, with early warning and optional real-time remote Bluetooth notification function
Battery3.7V rechargeable lithium battery, battery capacity 2200mA
Working HoursMore than 15 hours in continuous pumping mode
ChargerTravel charger with DC interface, charging time ≥ 4 hours
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Certification (EU regulations)CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Protection GradeIP67
Working Temperature-20℃~+50℃
Humidity0~90%RH (no condensation)
Environmental Pressure86~106Kpa
Size157*84.5*59.5mm (including the back clip/water trap filter) (length * width * height)
Weight365g (including battery, belt clip and filter)
Package Included1 piece Gas detector, 1 piece 12V/1A DC power adapter, 1 piece USB cable, 1 piece User manual, 1 piece Warranty card, 1 piece Filter, 1 piece Aluminum suitcase

Note 1:

  • If you require a gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.


Details

Explosion Proof Multi Gas Detector Details

Applications

Applications of Portable Multi Gas Detector

Tips: How to maintain portable gas detector?

  • Check the gas flow rate, usually 30/h. Excessive or too small flow will have a greater impact on the analyzer results.
  • Replace the filter paper: stop the air pump and drain the filter tank.
  • Check whether there is any air leakage in the gas system. Whether the diaphragm of the sobbing pump is damaged, whether the sealing ring of the sampling probe is broken, whether the four-way valve and condensate are damaged, etc.
  • Cleaning the sampling probe and dredging the sampling hole pipeline
  • Check whether the condenser is working normally, usually the temperature is adjusted within 3℃.
  • Check the measuring device room to see if it is dirty, and clean it in time.
Product reviews
Thanks for your advice
5
Skluk
Avatar
10/24/2021 7:59 PM
Thank you for providing the following information and suggestions. We will order the second explosion-proof multi-gas detector.
Was this review helpful? Yes No (0/0)
When should I calibrate your gas detector?
5
Curtise
Avatar
1/25/2022 7:59 PM
When should I calibrate your gas detector?
Was this review helpful? Yes No (0/0)
ATO Responded
Gas detector typically calibrated once a year, if used frequently, then it should be half a year.
The measured data is accurate
5
Adcock
Avatar
7/26/2022 1:40 AM
I bought this gas detector for use near my food processing plant and the measurements are accurate every time. I will buy this gas detector again.
Was this review helpful? Yes No (0/0)
How to detect H2?
5
Gray
Avatar
9/9/2022 2:50 AM
I want to know how to use this instrument to detect H2 accurately and can it detect H2 in N2 background gas without O2?
Was this review helpful? Yes No (0/0)
ATO Responded
The background gas requirement for this meter to accurately detect H2 is air. It can detect H2 in an N2 background gas without O2, but the continuous time for detection should Not exceed 10 minutes. Besides, our H2 sensor only can stand pressure 1bar ±10%.
Detect hydrogen.
5
Gray
Avatar
9/9/2022 2:55 AM
Can I test hydrogen continuously for 96 hours at a pump rate of 1?
Was this review helpful? Yes No (0/0)
ATO Responded
The sensor is based on electro-chemical principles. The background gas must contain oxygen to detect, and the concentration of oxygen and hydrogen must be 1:1. You can detect hydrogen below 10000ppm as long as the oxygen concentration is not lower than 1% VOL.
Only registered users can write reviews