Magnetic Water Flow Meter, Split Type PTFE Lining, DN15-DN1000

$1,098.87
Magnetic split water flow meter for sale, with PTFE lining, suitable for acids, alkalis, solvents, oils, fuels, and various chemicals. Many calibers available DN15-DN1000. Smart flow meter can display instantaneous flow rate, cumulative flow rate. The smart water flow meter widely used in chemical industry, chemical fiber, metallurgy, fertilizer, paper making.
SKU: ATO-FLOW-MWFM
*
Free Shipping
Delivery date: 8-12 days

Magnetic split water flow meter with PTFE lining, ideal for acids, alkalis, solvents, oils, fuels, and chemicals. Available in sizes DN15 to DN1000. Water flow meter widely used in chemical industry, chemical fiber, metallurgy, fertilizer, paper making, water supply and drainage, sewage treatment and other industrial sectors and agricultural irrigation water dosage of conductive liquid flow measurement and automatic control of the production process.

Specification

ModelATO-LDG-MIK
CaliberDN15-DN1000
FlangeStandard Carbon Steel (Optional stainless steel flange, contact customer service)
Rated Pressure RatingDN15-DN50, PN<4.0MPa
DN65-DN150, PN<1.6MPa
DN200-DN250, PN<1.0MPa
High pressure can be customized
Protection ClassIP68/IP67 (Contact customer service)
Medium TemperatureSensor: -25~180℃; Converter: -10~80℃
BuriabilityLess than 5m (IP68 protected split sensors only)
Depth of ImmersionLess than 3m (IP68 protected split sensors only)
Sensor CablesThe standard cable is 10m; other cables are recommended to be customized to a maximum length of 20m.
CommunicationRS485
OutputsCurrent (4-20mA), pulse, frequency, status switching
Communication FunctionsEmpty tube identification, electrode contamination
Graphic DisplayMonochrome LCD with white backlight; size: 128*64 pixels
Display Functions2 measured value screens (measurement, status, etc.)
Maximum Measurement Error±0.3% of measured value (flow rate 1m/s); ±2mm/s (flow rate <1m/s)
Repeatability0.002
Operating EnvironmentTemperature: -10°C to 55°C (for flowmeter sensor section: -10°C to 60°C)
Storage Temperature: -40°C to 65°C
Electrical ConductivityWater: Minimum 20 μS/cm (for water conductive measurement)
Others: Minimum 5 μS/cm (for other conductivity measurements)
MaterialSensor: Ferrite, Standard stainless steel
Power SupplyVoltage: 100-240VAC, 50/60Hz, 22VDC to 26VDC
Maximum Power: 15VA
Power Cable: 0.5mm² Cu/AWG20
OutputOutput Range: 4-20mA
Measurement Range: 20mA
Lower Limit: 4mA
Power Supply: 24VDC
Load: < 750Ω
Pulse and Frequency OutputPulse width: 0.25ms to 100ms
Pulse frequency: 50% (max flow rate 5L)
Frequency range: 5000 cps


Feature

Magnetic water flow meter split type feature

  • Instantaneous and Cumulative Flow Display: The smart water flow meter provides both instantaneous and cumulative flow measurements for real-time monitoring and total volume tracking.
  • Multiple Flow Units Switchable: Supports various flow units like liters, cubic meters, etc., offering flexibility for different measurement requirements.
  • Bidirectional Flow Measurement: This magnetic water flow meter allows bidirectional flow measurement without installation concerns, ensuring reliable data collection for both flow directions.
  • Standard 4-20 mA Output: The digital water flow meter comes with a built-in 4-20 mA output for easy data transmission to external devices or control systems.
  • RS485 Communication with Modbus Protocol: The smart flow meter supports RS485 communication with Modbus for seamless integration with industrial control systems.
  • IP65 Waterproof and Anti-corrosion Design: The magnetic water flow meter features durable PTFE lining and a three-proof design (waterproof, anti-fall, anti-leakage) for enhanced durability and reliability in harsh environments.
  • Enhanced Usability: The design and functionality of this smart water flow meter are optimized to improve overall usability and operational efficiency in various industrial applications.

Dimension (Unit:mm)

Magnetic water flow meter split type dimension

DNaDDon*A
1020090604*14
1520095654*14
20200105754*14
25200115854*14
322001401004*18
402001501104*18
502001651254*18
652001851458*18
802002001608*18
1002502201808*18
1252502502108*18
1503002852408*22
20035034029512*22
25045040535512*22


Flow Chart 

Calibre DNFlow Rate (m/s)
0.10.20.40.51101215
Volume (m3/s)
DN100.028270.05650.11310.14140.28272.8273.394.24
DN150.06360.1270.250.3180.6366.3627.6329.54
DN200.1310.2260.450.5661.13111.3113.57216.965
DN250.1760.350.710.88351.76717.6721.20426.965
DN320.28950.581.161.4482.89528.9534.7443.425
DN400.45250.91.812.624.52445.2454.20867.86
DN500.7071.4142.833.5357.06970.6984.36106
DN651.1952.394.785.97311.946119.5143.35179.2
DN801.813.627.249.04818.1181217.2217.2
DN1002.835.6511.3114.1428.27282.7339.24404.05
DN1254.428.8417.6722.0944.18441.5530.16662.7
DN1506.3612.725.531.8163.62636.2763.44954.3
DN20011.322.645.245.55113.111311357.21696.5
DN25017.735.470.788.36176.717672110.42650.5


Flow Rate Characteristic Curve

Flow rate characteristic curve

Application

Integral magnetic flow meter application

Tips: What are the characteristics of the four different linings - chloroprene, polyurethane, JPEFE and F46?

MaterialMain CharacteristicsMaximum Operating TemperatureApplications
NeopreneExcellent elasticity, high tensile strength, good wear resistance. Resistant to general low-concentration acids, alkalis, salts, and oxidation.80°C (Custom orders can reach 120°C)Suitable for water, sewage, weakly abrasive slurries, and mining slurries.
PolyurethaneExcellent abrasion resistance, but relatively poor resistance to acid, alkali, and salt.70°CSuitable for medium-strong abrasive slurries, coal, and mud.
JPEFEResists almost all chemicals, including sulfuric acid, hydrochloric acid, and oils. Suitable for high-temperature and high-speed fluids.100°CSuitable for corrosive chemicals and fluids in various industrial applications.
F46Excellent resistance to oxidation and high-pressure resistance.150°C (Custom orders can reach 150°C)Primarily used in sanitary applications and for chemical fluids requiring high resistance.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Magnetic split water flow meter with PTFE lining, ideal for acids, alkalis, solvents, oils, fuels, and chemicals. Available in sizes DN15 to DN1000. Water flow meter widely used in chemical industry, chemical fiber, metallurgy, fertilizer, paper making, water supply and drainage, sewage treatment and other industrial sectors and agricultural irrigation water dosage of conductive liquid flow measurement and automatic control of the production process.

Specification

ModelATO-LDG-MIK
CaliberDN15-DN1000
FlangeStandard Carbon Steel (Optional stainless steel flange, contact customer service)
Rated Pressure RatingDN15-DN50, PN<4.0MPa
DN65-DN150, PN<1.6MPa
DN200-DN250, PN<1.0MPa
High pressure can be customized
Protection ClassIP68/IP67 (Contact customer service)
Medium TemperatureSensor: -25~180℃; Converter: -10~80℃
BuriabilityLess than 5m (IP68 protected split sensors only)
Depth of ImmersionLess than 3m (IP68 protected split sensors only)
Sensor CablesThe standard cable is 10m; other cables are recommended to be customized to a maximum length of 20m.
CommunicationRS485
OutputsCurrent (4-20mA), pulse, frequency, status switching
Communication FunctionsEmpty tube identification, electrode contamination
Graphic DisplayMonochrome LCD with white backlight; size: 128*64 pixels
Display Functions2 measured value screens (measurement, status, etc.)
Maximum Measurement Error±0.3% of measured value (flow rate 1m/s); ±2mm/s (flow rate <1m/s)
Repeatability0.002
Operating EnvironmentTemperature: -10°C to 55°C (for flowmeter sensor section: -10°C to 60°C)
Storage Temperature: -40°C to 65°C
Electrical ConductivityWater: Minimum 20 μS/cm (for water conductive measurement)
Others: Minimum 5 μS/cm (for other conductivity measurements)
MaterialSensor: Ferrite, Standard stainless steel
Power SupplyVoltage: 100-240VAC, 50/60Hz, 22VDC to 26VDC
Maximum Power: 15VA
Power Cable: 0.5mm² Cu/AWG20
OutputOutput Range: 4-20mA
Measurement Range: 20mA
Lower Limit: 4mA
Power Supply: 24VDC
Load: < 750Ω
Pulse and Frequency OutputPulse width: 0.25ms to 100ms
Pulse frequency: 50% (max flow rate 5L)
Frequency range: 5000 cps


Feature

Magnetic water flow meter split type feature

  • Instantaneous and Cumulative Flow Display: The smart water flow meter provides both instantaneous and cumulative flow measurements for real-time monitoring and total volume tracking.
  • Multiple Flow Units Switchable: Supports various flow units like liters, cubic meters, etc., offering flexibility for different measurement requirements.
  • Bidirectional Flow Measurement: This magnetic water flow meter allows bidirectional flow measurement without installation concerns, ensuring reliable data collection for both flow directions.
  • Standard 4-20 mA Output: The digital water flow meter comes with a built-in 4-20 mA output for easy data transmission to external devices or control systems.
  • RS485 Communication with Modbus Protocol: The smart flow meter supports RS485 communication with Modbus for seamless integration with industrial control systems.
  • IP65 Waterproof and Anti-corrosion Design: The magnetic water flow meter features durable PTFE lining and a three-proof design (waterproof, anti-fall, anti-leakage) for enhanced durability and reliability in harsh environments.
  • Enhanced Usability: The design and functionality of this smart water flow meter are optimized to improve overall usability and operational efficiency in various industrial applications.

Dimension (Unit:mm)

Magnetic water flow meter split type dimension

DNaDDon*A
1020090604*14
1520095654*14
20200105754*14
25200115854*14
322001401004*18
402001501104*18
502001651254*18
652001851458*18
802002001608*18
1002502201808*18
1252502502108*18
1503002852408*22
20035034029512*22
25045040535512*22


Flow Chart 

Calibre DNFlow Rate (m/s)
0.10.20.40.51101215
Volume (m3/s)
DN100.028270.05650.11310.14140.28272.8273.394.24
DN150.06360.1270.250.3180.6366.3627.6329.54
DN200.1310.2260.450.5661.13111.3113.57216.965
DN250.1760.350.710.88351.76717.6721.20426.965
DN320.28950.581.161.4482.89528.9534.7443.425
DN400.45250.91.812.624.52445.2454.20867.86
DN500.7071.4142.833.5357.06970.6984.36106
DN651.1952.394.785.97311.946119.5143.35179.2
DN801.813.627.249.04818.1181217.2217.2
DN1002.835.6511.3114.1428.27282.7339.24404.05
DN1254.428.8417.6722.0944.18441.5530.16662.7
DN1506.3612.725.531.8163.62636.2763.44954.3
DN20011.322.645.245.55113.111311357.21696.5
DN25017.735.470.788.36176.717672110.42650.5


Flow Rate Characteristic Curve

Flow rate characteristic curve

Application

Integral magnetic flow meter application

Tips: What are the characteristics of the four different linings - chloroprene, polyurethane, JPEFE and F46?

MaterialMain CharacteristicsMaximum Operating TemperatureApplications
NeopreneExcellent elasticity, high tensile strength, good wear resistance. Resistant to general low-concentration acids, alkalis, salts, and oxidation.80°C (Custom orders can reach 120°C)Suitable for water, sewage, weakly abrasive slurries, and mining slurries.
PolyurethaneExcellent abrasion resistance, but relatively poor resistance to acid, alkali, and salt.70°CSuitable for medium-strong abrasive slurries, coal, and mud.
JPEFEResists almost all chemicals, including sulfuric acid, hydrochloric acid, and oils. Suitable for high-temperature and high-speed fluids.100°CSuitable for corrosive chemicals and fluids in various industrial applications.
F46Excellent resistance to oxidation and high-pressure resistance.150°C (Custom orders can reach 150°C)Primarily used in sanitary applications and for chemical fluids requiring high resistance.
Only registered users can write reviews