K type Thermocouple with Transmitter

$153.94
K type thermocouple assembles with protection head and stainless steel thermowell, built-in small transmitter. It converts temperature to 4-20mA standard signal, and outputs to display instrument or DCS system in control room. Transmitter adopts silicone rubber seal structure, save extension wire, good anti-interference ability. Measuring temperature range 0~1000 ℃.
SKU: ATO-TC-KT
*
*
Free Shipping
Delivery date: 6-12 days

K type thermocouple built-in transmitter can directly provide accurate input signal of temperature changes for display instruments, recording instruments, signal conditioners, scanister and computer.

Specification

1. Thermocouple temperature range chart

Type of sensing elementTemperature range
E type0~400℃
0~600℃
K type0~400℃
0~600℃
0~800℃
0~1000℃
S type600~1600℃
B type800~1800℃
N type0~400℃
0~600℃
0~800℃
0~1100℃
0~1200℃

2. Transmitter parameter chart

InputThermocouple: K, E, B, S, T, N
Output4-20mA
Intrinsic error±0.5%
Transmission modeTwo wire
Supply voltageDC 12~35V, rated voltage DC 24V
Load resistance0~600Ω (DC 24V), rated load 250Ω
Temperature influence≤0.05/1℃
Working environmentTemperature: -25~+80℃,humidity: 5%~95%, mechanical vibration: f≤55Hz, amplitude<0.15mm

3. Meter and protection head type (unit: mm)
RTD sensor meter and protection head type

4. Selection chart

Type of sensing elementMeter typeInstalling formMode of connectionThermowell diameterThermowell total length
S1: E type;
S2: K type;
S3: S type;
S4: B type;
S5: T type;
S6: J type;
S8: N type;
P0: No meter;
P2: Meter with digital display;
P4: Intelligent meter with digital display
I1: No fixed device;
I2: Fixed card sets of thread joint;
I3: Movable card sets of thread joint;
I4: Fixed card sets of flange;
I5: Rectangular movable flange;
I6: Taper thermowell and fixing thread
C3: Standard waterproof protection head;
C4: Explosion-proof protection head
D0: Φ16mm300~2150mm

Note: The sensing element is sheath thermocouple, thermowell material is stainless steel, and circuit adopts non-isolated type. When ordering products, write the thermowell insertion depth l and the corresponding temperature range for output 4~20mA signal you need.

Application

K type thermocouple with transmitter application
Tips: How to connect thermocouple and DCS

  1. Thermocouple uses extension wire and there are nodes in the middle, but corresponding compensating cable must be used and directly connected to DCS thermocouple module. It is necessary to reduce nodes as far as possible so as to reduce interference. In addition, DCS configuration should select corresponding thermocouple model and compensating method as well.
  2. Thermocouple uses transmitter (temperature transmitter) in the field and transforms into 4~20mA standard signal. Then, connect it with the indoor safety grid (if necessary, such as chemical environments) and connect with DCS standard analog quantity card (general AI card). It is noteworthy that compensating cable is necessary from thermocouple to transmitter. Transmitter needs to set compensating method, thermocouple type and calibration range, and DCS should set range and signal type.

Fixed Installation Dimension Drawing

Design serial number1
Structure diagramThermocouple RDT sensor dimension
NameFixed thread
SizeM27*2 (default), G3/4", M33*2, G1", other
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≤10MPa
Design serial number2
Structure diagramThermocouple RDT sensor dimension
NameMovable flange
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltageAtmospheric pressure
Design serial number3
Structure diagramThermocouple RDT sensor dimension
NameFixed flange
SizeDN15mm (default)D095mmDN20mm105mm
D165mm75mm
D245mm55mm
φn4-φ14mm4-φ14mm
DN25mmD0115mmDN32mm140mm
D185mm100mm
D265mm78mm
φn4-φ14mm4-φ18mm
DN40mmD0150mmDN50mm165mm
D1110mm125mm
D285mm100mm
φn4-φ18mm4-φ18mm
H12mm
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≤6.4MPa
Design serial number4
Structure diagramThermocouple RDT sensor dimension
NameConical fixed thread
SizeM27*2 (default), M33*2, G1", other
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≥30MPa
Product reviews
K-type thermocouples
5
Kolicaceae
Avatar
5/13/2025 9:03 PM
I am looking for 3 certified K-type thermocouples, 600mm long, 0℃ to 100℃ range, 4-20 mA output signal, any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we do not have dual thermocouples. For K-type thermocouples, please refer to this model ATO-TC-KT.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

K type thermocouple built-in transmitter can directly provide accurate input signal of temperature changes for display instruments, recording instruments, signal conditioners, scanister and computer.

Specification

1. Thermocouple temperature range chart

Type of sensing elementTemperature range
E type0~400℃
0~600℃
K type0~400℃
0~600℃
0~800℃
0~1000℃
S type600~1600℃
B type800~1800℃
N type0~400℃
0~600℃
0~800℃
0~1100℃
0~1200℃

2. Transmitter parameter chart

InputThermocouple: K, E, B, S, T, N
Output4-20mA
Intrinsic error±0.5%
Transmission modeTwo wire
Supply voltageDC 12~35V, rated voltage DC 24V
Load resistance0~600Ω (DC 24V), rated load 250Ω
Temperature influence≤0.05/1℃
Working environmentTemperature: -25~+80℃,humidity: 5%~95%, mechanical vibration: f≤55Hz, amplitude<0.15mm

3. Meter and protection head type (unit: mm)
RTD sensor meter and protection head type

4. Selection chart

Type of sensing elementMeter typeInstalling formMode of connectionThermowell diameterThermowell total length
S1: E type;
S2: K type;
S3: S type;
S4: B type;
S5: T type;
S6: J type;
S8: N type;
P0: No meter;
P2: Meter with digital display;
P4: Intelligent meter with digital display
I1: No fixed device;
I2: Fixed card sets of thread joint;
I3: Movable card sets of thread joint;
I4: Fixed card sets of flange;
I5: Rectangular movable flange;
I6: Taper thermowell and fixing thread
C3: Standard waterproof protection head;
C4: Explosion-proof protection head
D0: Φ16mm300~2150mm

Note: The sensing element is sheath thermocouple, thermowell material is stainless steel, and circuit adopts non-isolated type. When ordering products, write the thermowell insertion depth l and the corresponding temperature range for output 4~20mA signal you need.

Application

K type thermocouple with transmitter application
Tips: How to connect thermocouple and DCS

  1. Thermocouple uses extension wire and there are nodes in the middle, but corresponding compensating cable must be used and directly connected to DCS thermocouple module. It is necessary to reduce nodes as far as possible so as to reduce interference. In addition, DCS configuration should select corresponding thermocouple model and compensating method as well.
  2. Thermocouple uses transmitter (temperature transmitter) in the field and transforms into 4~20mA standard signal. Then, connect it with the indoor safety grid (if necessary, such as chemical environments) and connect with DCS standard analog quantity card (general AI card). It is noteworthy that compensating cable is necessary from thermocouple to transmitter. Transmitter needs to set compensating method, thermocouple type and calibration range, and DCS should set range and signal type.
Product reviews
K-type thermocouples
5
Kolicaceae
Avatar
5/13/2025 9:03 PM
I am looking for 3 certified K-type thermocouples, 600mm long, 0℃ to 100℃ range, 4-20 mA output signal, any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we do not have dual thermocouples. For K-type thermocouples, please refer to this model ATO-TC-KT.
Only registered users can write reviews
Customers who bought this item also bought

Temp and Humidity Sensor/Transmitter, Duct Mounted, 4-20mA

ATO-TAHT-AF1020
$117.98
Temperature and humidity transmitter adopts digital temperature and humidity sensor AM2305, and converts the air temperature and humidity into 4-20mA standard signal. Industrial temperature and humidity transmitter has dustproof PC housing, metal filter screen, wide measuring range, high accuracy, anti-chemical pollution, excellent long-term stability and repeatability.