Cheap yet reliable industrial solid state relay (SSR), is available with 80 Amp, 100 Amp and 120 Amp load current. This DC to AC SSR is an ideal module for automatic control system like petrochemical equipment, pharmaceutical machines, food machines, packaging machines, etc., especially suitable for corrosive, humid, dusty and other harsh environment.

Specification

ModelATO-GYSSR-80DA(H2)ATO-GYSSR-100DA(H2)ATO-GYSSR-120DA(H2)
Control Voltage3-32VDC
Control CurrentDC 7-32mA
Load Current80A100A120A
Load Voltage24-440V AC
On-State Voltage Drop≤1.5V
Off-State Leakage Current≤4mA
Off-State Time≤10mS
Dielectric Strength2500V AC
Insulation Resistance1000MΩ/ 500V DC
Ambient Temperature-20 ~ +70℃
Mounting MethodBolt Fixing
Working IndicatorLED
Weight145g
Dimension (L*W*H)94*25*38mm
Heat Sink (Optional)More info., please click here.

Dimension (Unit: mm)

80A/100A/120A Industrial Solid State Relay Dimension

Wiring Diagram

industrial Solid State Relay SSR-120DA Wiring Diagram

Operation Note

1. For the resistive load, it can not exceed 60% of the rated current of the SSR.
2. For the inductive or capacitive load, it can not exceed 40% of the rated current of the SSR.
3. For the electric motor, it can not exceed 20% of the rated current of the SSR.
4. Proper radiator or heat sink should be equipped for the industrial solid state relay. If the load cooling condition is not good, it is necessary to leave some margin. Avoid the load short circuit because over current and short circuit are the main causes for permanent damage of the internal SCR of the SSR.
5. Over current protection: Using fast fuse and air switch is one of the methods for over current protection; fuse is also available for small capacity.
6. Over voltage protection: It can adopt the parallel voltage-dependent resistor (MOV). The MOV area decides the absorption power, and its thickness decides the protective voltage value. Generally, 471/10D voltage-dependent resistor is suitable for 220V series SSR, 681/10D voltage-dependent resistor for 380V series SSR, and 821/10D voltage-dependent resistor for 480V series SSR.

Tips: Usage of Solid State Relay – Capacitive Load

Although the capacitive load is not very common, the solid state relay will also be used for it sometimes. Much attention should be paid to the low-impedance capacitive load, and the di/dt of the SSR can not be exceeded. If there is no extra limitation to the impedance, the capacitive load di/dt can approach infinity during powering. It is very useful way to limit the capacitive load di/dt by zero-crossing switching type SSR. When using a solid state relay, the safety range of maximum blocking voltage should be considered. If it discharges near the peak of the line voltage, it will cause a destructive di/dt value, which will easily make the load breakover, so the transient voltage of capacitive load must be limited. For large capacitive load, it is necessary to limit the di/dt within the stipulated value by series circuit impedance, which can protect the SSR from suffering the accidental yet unavoidable high transient voltage.

How to Choose the DC-AC Industrial Solid State Relay Model?

In this video, we show you the available models of ATO solid state relays for controlling industrial heavy loads. At the same time, we introduce their main design features and key specifications.

Product reviews
Solid and efficient
5
cxcx
Avatar
9/10/2025 11:58 PM
I’ve been using the 80A DC to AC industrial solid state relay for a few months now, and it has performed flawlessly. The compact size makes it easy to fit into my control panel, and I really appreciate the fast switching speed with no noise or sparking — a big improvement over traditional relays. It’s been especially reliable in my automation setup, handling heavy loads smoothly without overheating. Overall, it’s a solid, efficient, and low-maintenance SSR that I’d definitely recommend to anyone working in industrial automation.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Cheap yet reliable industrial solid state relay (SSR), is available with 80 Amp, 100 Amp and 120 Amp load current. This DC to AC SSR is an ideal module for automatic control system like petrochemical equipment, pharmaceutical machines, food machines, packaging machines, etc., especially suitable for corrosive, humid, dusty and other harsh environment.

Specification

ModelATO-GYSSR-80DA(H2)ATO-GYSSR-100DA(H2)ATO-GYSSR-120DA(H2)
Control Voltage3-32VDC
Control CurrentDC 7-32mA
Load Current80A100A120A
Load Voltage24-440V AC
On-State Voltage Drop≤1.5V
Off-State Leakage Current≤4mA
Off-State Time≤10mS
Dielectric Strength2500V AC
Insulation Resistance1000MΩ/ 500V DC
Ambient Temperature-20 ~ +70℃
Mounting MethodBolt Fixing
Working IndicatorLED
Weight145g
Dimension (L*W*H)94*25*38mm
Heat Sink (Optional)More info., please click here.

Dimension (Unit: mm)

80A/100A/120A Industrial Solid State Relay Dimension

Wiring Diagram

industrial Solid State Relay SSR-120DA Wiring Diagram

Operation Note

1. For the resistive load, it can not exceed 60% of the rated current of the SSR.
2. For the inductive or capacitive load, it can not exceed 40% of the rated current of the SSR.
3. For the electric motor, it can not exceed 20% of the rated current of the SSR.
4. Proper radiator or heat sink should be equipped for the industrial solid state relay. If the load cooling condition is not good, it is necessary to leave some margin. Avoid the load short circuit because over current and short circuit are the main causes for permanent damage of the internal SCR of the SSR.
5. Over current protection: Using fast fuse and air switch is one of the methods for over current protection; fuse is also available for small capacity.
6. Over voltage protection: It can adopt the parallel voltage-dependent resistor (MOV). The MOV area decides the absorption power, and its thickness decides the protective voltage value. Generally, 471/10D voltage-dependent resistor is suitable for 220V series SSR, 681/10D voltage-dependent resistor for 380V series SSR, and 821/10D voltage-dependent resistor for 480V series SSR.

Tips: Usage of Solid State Relay – Capacitive Load

Although the capacitive load is not very common, the solid state relay will also be used for it sometimes. Much attention should be paid to the low-impedance capacitive load, and the di/dt of the SSR can not be exceeded. If there is no extra limitation to the impedance, the capacitive load di/dt can approach infinity during powering. It is very useful way to limit the capacitive load di/dt by zero-crossing switching type SSR. When using a solid state relay, the safety range of maximum blocking voltage should be considered. If it discharges near the peak of the line voltage, it will cause a destructive di/dt value, which will easily make the load breakover, so the transient voltage of capacitive load must be limited. For large capacitive load, it is necessary to limit the di/dt within the stipulated value by series circuit impedance, which can protect the SSR from suffering the accidental yet unavoidable high transient voltage.

Product reviews
Solid and efficient
5
cxcx
Avatar
9/10/2025 11:58 PM
I’ve been using the 80A DC to AC industrial solid state relay for a few months now, and it has performed flawlessly. The compact size makes it easy to fit into my control panel, and I really appreciate the fast switching speed with no noise or sparking — a big improvement over traditional relays. It’s been especially reliable in my automation setup, handling heavy loads smoothly without overheating. Overall, it’s a solid, efficient, and low-maintenance SSR that I’d definitely recommend to anyone working in industrial automation.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews