High Precision Digital Ultrasonic Thickness Gauge for Sheet Metal/Steel

$5,468.10
Digital ultrasonic thickness gauge, offers high precision thickness testing of thin materials, like sheet metal, sheet steel, etc., through-painting thickness measurement also available, 0.001mm resolution, 310 m/s~18,699 m/s material velocity range, big and clear OLED screen, multi-measuring mode to make the readings more accurate and reliable.
SKU: ATO-PM-5
*
Free Shipping
Delivery date: 6-12 days

Digital ultrasonic thickness gauge is high precision with 0.001mm resolution, especially suitable for the thickness measurement of thin-walled materials, like car body sheet, fire/security doors and extinguisher, etc.

Features

  • High resolution 0.001mm
  • Real-time A-Scan with adjustable gain, range, blanking, etc.
  • Designed for thin workpiece, with lower measurement limit to 0.2mm
  • 2.4" QVGA (320×240 pixels) OLED color display
  • With through coating measurement, the gauge can measure the net thickness of the substrate without removing the paintings.
  • Unique multiple-wave verify mode, all the thickness values have been checked through 3 to 9 times of echos, which makes the result more reliable and accurate.

Specification

MeasurementModelATO-PM5 Gen3
Probe Frequency Range2.25 MHz~20 MHz (standard frequency)2.25 MHz~75 MHz (high-frequency)
Measurement Range in Steel0.15 mm~10 m0.05 mm~10 m
Resolution0.001 mm / 0.0001 in / 1 µm / 0.1 mil0.0001 mm / 0.00001 in / 0.1 µm / 0.01 mil
Measurement ModesPulse-Echo, Interface-Echo, Echo-Echo, Multiple Echo Verification, Automatic
Probe TypesSingle-Element Probe (delay line, contact, protective membrane, pencil, water immersion)
Measurement Unitsmm, inch, µm, mil; m/s, in/µs, ns, µs (ultrasonic velocity meter and time-of-flight option)
Sound Velocity Range310 m/s~18,699 m/s, measures sound velocity based on a known thickness sample
Display Update RateSelectable at 4 Hz, 8 Hz or 16 Hz
Measuring FunctionsUpper, lower limit alarm, min/max value, difference, reduction rate, B-Scan
Data Logger100,000 readings, 400 setup files, PC software and USB drive included
Digital Frequency200 MHz
DisplayDisplay Screen2.4-inch (320×240 dot matrix), IPS wide-angle color display
Rectification ModesRF, RF-, FULL, HALF+, HALF-
View ModesLarge digits, A-Scan, B-Scan, A-Scan, storage grid
InterfaceProbe ConnectorLEMO 00
I/O ConnectorLEMO 00 4-pin
Communication InterfaceMini USB (Optional RS-232)
General SpecsOperating Temperature-10°C~50°C
PowerTwo AA batteries, USB-powered (real-time communication option)
Battery LifeUp to 22 hours continuous operation (AA Alkaline or AA Lithium batteries)
Power OffSelectable automatic shut-off after 5, 10, or 20 minutes of inactivity, or manual shut-off only
HousingThe impact-resistant, waterproof housing with a sealing gasket is designed to meet the IP67 standard
Dimensions153*76*37 mm (H×W×D)
Weight280g

Note:
* Standard Packing List

  • 1*Ultrasonic Thickness Gauge
  • 1*probe (with test report)
  • 2*batteries
  • 1*communication cable
  • 1*product packaging box
  • 1*set of certificate of conformity, warranty card, and packing list
  • 1*bottle of coupling agent
  • 1*probe cable
  • 1*rubber protective sleeve
  • 1*communication USB flash drive
  • 1*user manual
  • 1*factory calibration certificate

(Kindly Reminder: Battery and Couplant is Not Included if Shipped By Air.)

Tips: What are the factors affecting the value of ultrasonic thickness gauge?

1. The surface roughness of the workpiece is too large, resulting in poor coupling effect between the probe and the contact surface, low reflection echo, and even unable to receive the echo signal.

2. When the radius of curvature of workpiece is too small, especially when measuring thickness of small diameter tube, the sound intensity transmittance is low because the surface of common probe is plane and the contact with surface is point contact or line contact.

3. The detection surface is not parallel to the bottom, and the acoustic wave scatters when it meets the bottom, so the probe of ultrasonic thickness gauge cannot accept the signal of the bottom wave.

4. Castings and austenitic steels have severe scattering attenuation when the ultrasonic wave pass through due to inhomogeneous structure or coarse grain. The scattered ultrasonic wave propagates along complex paths, which may obliterate the echo and cause no display.

5. There is some wear on the contact surface of the probe.

6. There are a lot of corrosion pits on the back of the measured object.

7. There is sediment in the measured workpiece (such as pipeline). When the acoustic impedance difference between the sediment and the workpiece is small, the ultrasonic thickness gauge shows that the thickness reading is increased by the thickness of the sediment.

8. When there are defects (such as inclusions, sandwiches, etc.) in the material, the display value is about 70% of the nominal thickness. At this time, the ultrasonic flaw detector can be used for further defect detection.

9. The temperature will affect the reading of ultrasonic thickness gauge. Sound velocity in general solid materials decreases with increasing temperature.

10. Cascade material and composite (heterogeneous) material. It is impossible to measure uncoupled laminated materials because ultrasound cannot penetrate uncoupled space and cannot propagate uniformly in composite (heterogeneous) materials.

11. The influence of coupling agent. Sound speed is selected incorrectly. Metal surface oxide or paint coating may also affect the thickness value of ultrasonic thickness gauge.

Product reviews
Simple to use
5
Javier
Avatar
12/7/2022 12:02 AM
We had an acrylic resin we were not able to acquire the thickness through the whole piece. This ultrasonic thickness gauge is pretty simple to use it collects data it did what we needed it to do.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Digital ultrasonic thickness gauge is high precision with 0.001mm resolution, especially suitable for the thickness measurement of thin-walled materials, like car body sheet, fire/security doors and extinguisher, etc.

Features

  • High resolution 0.001mm
  • Real-time A-Scan with adjustable gain, range, blanking, etc.
  • Designed for thin workpiece, with lower measurement limit to 0.2mm
  • 2.4" QVGA (320×240 pixels) OLED color display
  • With through coating measurement, the gauge can measure the net thickness of the substrate without removing the paintings.
  • Unique multiple-wave verify mode, all the thickness values have been checked through 3 to 9 times of echos, which makes the result more reliable and accurate.

Specification

MeasurementModelATO-PM5 Gen3
Probe Frequency Range2.25 MHz~20 MHz (standard frequency)2.25 MHz~75 MHz (high-frequency)
Measurement Range in Steel0.15 mm~10 m0.05 mm~10 m
Resolution0.001 mm / 0.0001 in / 1 µm / 0.1 mil0.0001 mm / 0.00001 in / 0.1 µm / 0.01 mil
Measurement ModesPulse-Echo, Interface-Echo, Echo-Echo, Multiple Echo Verification, Automatic
Probe TypesSingle-Element Probe (delay line, contact, protective membrane, pencil, water immersion)
Measurement Unitsmm, inch, µm, mil; m/s, in/µs, ns, µs (ultrasonic velocity meter and time-of-flight option)
Sound Velocity Range310 m/s~18,699 m/s, measures sound velocity based on a known thickness sample
Display Update RateSelectable at 4 Hz, 8 Hz or 16 Hz
Measuring FunctionsUpper, lower limit alarm, min/max value, difference, reduction rate, B-Scan
Data Logger100,000 readings, 400 setup files, PC software and USB drive included
Digital Frequency200 MHz
DisplayDisplay Screen2.4-inch (320×240 dot matrix), IPS wide-angle color display
Rectification ModesRF, RF-, FULL, HALF+, HALF-
View ModesLarge digits, A-Scan, B-Scan, A-Scan, storage grid
InterfaceProbe ConnectorLEMO 00
I/O ConnectorLEMO 00 4-pin
Communication InterfaceMini USB (Optional RS-232)
General SpecsOperating Temperature-10°C~50°C
PowerTwo AA batteries, USB-powered (real-time communication option)
Battery LifeUp to 22 hours continuous operation (AA Alkaline or AA Lithium batteries)
Power OffSelectable automatic shut-off after 5, 10, or 20 minutes of inactivity, or manual shut-off only
HousingThe impact-resistant, waterproof housing with a sealing gasket is designed to meet the IP67 standard
Dimensions153*76*37 mm (H×W×D)
Weight280g

Note:
* Standard Packing List

  • 1*Ultrasonic Thickness Gauge
  • 1*probe (with test report)
  • 2*batteries
  • 1*communication cable
  • 1*product packaging box
  • 1*set of certificate of conformity, warranty card, and packing list
  • 1*bottle of coupling agent
  • 1*probe cable
  • 1*rubber protective sleeve
  • 1*communication USB flash drive
  • 1*user manual
  • 1*factory calibration certificate

(Kindly Reminder: Battery and Couplant is Not Included if Shipped By Air.)

Tips: What are the factors affecting the value of ultrasonic thickness gauge?

1. The surface roughness of the workpiece is too large, resulting in poor coupling effect between the probe and the contact surface, low reflection echo, and even unable to receive the echo signal.

2. When the radius of curvature of workpiece is too small, especially when measuring thickness of small diameter tube, the sound intensity transmittance is low because the surface of common probe is plane and the contact with surface is point contact or line contact.

3. The detection surface is not parallel to the bottom, and the acoustic wave scatters when it meets the bottom, so the probe of ultrasonic thickness gauge cannot accept the signal of the bottom wave.

4. Castings and austenitic steels have severe scattering attenuation when the ultrasonic wave pass through due to inhomogeneous structure or coarse grain. The scattered ultrasonic wave propagates along complex paths, which may obliterate the echo and cause no display.

5. There is some wear on the contact surface of the probe.

6. There are a lot of corrosion pits on the back of the measured object.

7. There is sediment in the measured workpiece (such as pipeline). When the acoustic impedance difference between the sediment and the workpiece is small, the ultrasonic thickness gauge shows that the thickness reading is increased by the thickness of the sediment.

8. When there are defects (such as inclusions, sandwiches, etc.) in the material, the display value is about 70% of the nominal thickness. At this time, the ultrasonic flaw detector can be used for further defect detection.

9. The temperature will affect the reading of ultrasonic thickness gauge. Sound velocity in general solid materials decreases with increasing temperature.

10. Cascade material and composite (heterogeneous) material. It is impossible to measure uncoupled laminated materials because ultrasound cannot penetrate uncoupled space and cannot propagate uniformly in composite (heterogeneous) materials.

11. The influence of coupling agent. Sound speed is selected incorrectly. Metal surface oxide or paint coating may also affect the thickness value of ultrasonic thickness gauge.

Product reviews
Simple to use
5
Javier
Avatar
12/7/2022 12:02 AM
We had an acrylic resin we were not able to acquire the thickness through the whole piece. This ultrasonic thickness gauge is pretty simple to use it collects data it did what we needed it to do.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews