Clamp-on Ground Resistance Tester, 0 to 200kΩ

$1,060.25
Get a clamp-on earth resistance tester on ATO.com for measuring grounding resistance, loop resistance, soil resistivity, voltage to ground, and grounding down conductor leakage current. Digital earth tester comes with a 0.000mA~20A current range, 0.00Ω~200kΩ measurement range, 5-inch color LCD screen, USB interface charging port, storage function and clock function is available.
SKU: ATO-ERT-200k
Free Shipping
Delivery date: 6-12 days

Buy a high-precision clamp ground resistance tester online. It is provided with a 0.000mA~20A current range, 0~200kΩ measurement range, 5-inch color LCD screen, USB interface charging port, storage function and clock function. Digital earth resistance tester is suitable for measuring grounding resistance, loop resistance, soil resistivity, voltage to ground, and grounding down conductor leakage current.

Features

  • ATO earth resistance tester is available with a 32mm clamp and 0Ω~200kΩ measure range.
  • Clamp on earth resistance tester is designed for on-site measurement of ground resistance, soil resistivity, ground current, and ground voltage. It has a 2.5-inch color LCD screen. and USB interface charging port,
  • storage function, and clock function, and automatically stores 500 groups.
  • Digital ground resistance testers can measure grounding resistance by various measurement methods such as the clamp meter method, two-wire method, three-wire method, four-wire method, and selection method.

Specifications

ModelATO-ERT-2300B
Resistance Range0.00Ω~200kΩ
Soil Resistivity Range0Ωm~9999kΩm
Ground Current Range0.000mA~20A
Ground Voltage Range0.0V~600.0V
Earth Resistance Measurement MethodsClamp meter method, two-wire method, three-wire method, four-wire method, selection method
Test Frequency128Hz/111Hz/105Hz/94Hz (AFC automatic frequency selection)
Display Mode2.5-inch color LCD screen
Short Circuit Test CurrentAC 10mA max
Open Circuit Test VoltageAC 14V max
Electrode Spacing Range1m~100m
Weight5.1 kg
Clamp Size65mm×32mm
Tester Size307mm×98mm×56mm
Test Line4 Pieces (red 20m, black 20m, yellow 10m, green 10m)
Simple Test Line2 Pieces (red 1.6m, black 1.6m)
Auxiliary Ground Rod4*Φ9mm×230mm (935g)
Measurement Timesmore than 5000 times (short circuit test, test once, stop for 30 seconds and test again)
Line Voltagemeasured below AC 600V
Data Memory500 groups
Audible And Visible Alarm"du—du—du" for alarming, press AL to turn on/off
Automatic Shut-DownAutomatic shutdown after 5 minutes of power on
ShiftAutomatically
External Magnet/Electric Field< 40A/m, < 1V/m
Resistance Test Frequency>1KHz, 128Hz
InterfaceUSB interface
AccessoriesResistance Tester: 1PCS; Test Loop:1PCS; Test Ring: 1PCS; USB Charging Cable:1PCS; Charger: 1PCS; Ground Pin: 4PCS; Test Leads: 4PCS; Simple Test Leads: 2PCS; Tool Box: 1PCS


Range and Accuracy

Measuring FunctionMeasuring RangeAccuracyResolution
Measuring Grounding Resistance with Clamp Meter0.010Ω~0.099Ω±(1%rdg+0.05Ω)0.001Ω
0.10Ω~0.99Ω±(1%rdg+0.05Ω)0.01Ω
1.0Ω~49.9Ω±(1%rdg+0.5Ω)0.1Ω
50.0Ω~99.5Ω±(2%rdg+0.5Ω)0.5Ω
100Ω~199Ω±(5%rdg+1Ω)1Ω
Two-Three-Four-Wire Method for Measuring Grounding Resistance0.10Ω~20.00Ω±2%rdg±5dgt0.01Ω
20.0Ω~200.0Ω±2%rdg±5dgt0.1Ω
200Ω~2000Ω±2%rdg±5dgt1Ω
2.00kΩ~20.00kΩ±4%rdg±5dgt10Ω
Selective Method for measuring grounding resistance0.10Ω~20.00Ω±2%rdg±5dgt0.01Ω
20.0Ω~200.0Ω±2%rdg±5dgt0.1Ω
200Ω~2000Ω±2%rdg±5dgt1Ω
Soil Resistivity0.00Ωm~99.99ΩmDepends on the measurement accuracy of the R
(ρ=2πaR
a:1m~100m;
π=3.14)
0.01Ωm
100.0Ωm~999.9Ωm0.1Ωm
1000Ωm~9999Ωm1Ωm
10.00kΩm~99.99k10Ωm
100.0kΩm~999.9k100Ωm
1000kΩm~9999kΩmπ=3.14)1kΩm
Ground Voltage 50Hz/60HzAC 0.0~600.0V±2%rdg±5dgt0.1V
Ground Current 50Hz/60Hz0.000mA~5.000mA±(2.5%rdg+1mA)0.001mA
5.0mA~100.0mA±(2.5%rdg+5mA)0.1mA
100mA~500mA±(2.5%rdg+10mA)1mA
0.50A~20.00A±(2.5%rdg+0.5A)0.01A
*20.0A~45.0A±(2.5%rdg+0.5A)0.1A

Note

  • The additional error when rC max or rP max is ≤±5%rdg±5dgt.
  • rC max: 4kΩ+100R<50kΩ, rP max: 4kΩ+100R<50kΩ
  • The additional error at 2.5V interference voltage is ≤±5%rdg±5dgt.

Details

Clamp earth resistance tester details

Applications

ATO provides earth resistance testers with a measurement range of 0.00Ω-300kΩ, which are widely used in ground resistance measurement and loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil fields, construction, and industrial electrical equipment. When measuring the grounding system with a loop, the ground resistance tester does not need auxiliary electrodes and does not need to disconnect the grounding wire, which is safer and faster.

Clamp earth resistance tester applicationsTips: What are the factors that affect soil resistivity?

  • Soil resistivity is the average value of soil resistance per unit length, measured in ohm meters. The main factors affecting soil resistivity are as follows:
  • Different soil types have different soil resistivities.
    When the temperature drops again, ρ increases significantly. As the temperature starts to rise from 0°C, ρ will only decrease steadily.
  • The size of the soil resistivity ρ mainly depends on the concentration of conductive ions in the soil and the water content in the soil. The higher the concentration of conductive ions in the soil, the better the conductivity of the soil and the smaller ρ.
  • The density of the soil affects the soil resistivity.
  • Seasonal changes will cause changes in soil resistivity, and the most obvious factors affecting soil resistivity are rainfall and freezing.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Buy a high-precision clamp ground resistance tester online. It is provided with a 0.000mA~20A current range, 0~200kΩ measurement range, 5-inch color LCD screen, USB interface charging port, storage function and clock function. Digital earth resistance tester is suitable for measuring grounding resistance, loop resistance, soil resistivity, voltage to ground, and grounding down conductor leakage current.

Features

  • ATO earth resistance tester is available with a 32mm clamp and 0Ω~200kΩ measure range.
  • Clamp on earth resistance tester is designed for on-site measurement of ground resistance, soil resistivity, ground current, and ground voltage. It has a 2.5-inch color LCD screen. and USB interface charging port,
  • storage function, and clock function, and automatically stores 500 groups.
  • Digital ground resistance testers can measure grounding resistance by various measurement methods such as the clamp meter method, two-wire method, three-wire method, four-wire method, and selection method.

Specifications

ModelATO-ERT-2300B
Resistance Range0.00Ω~200kΩ
Soil Resistivity Range0Ωm~9999kΩm
Ground Current Range0.000mA~20A
Ground Voltage Range0.0V~600.0V
Earth Resistance Measurement MethodsClamp meter method, two-wire method, three-wire method, four-wire method, selection method
Test Frequency128Hz/111Hz/105Hz/94Hz (AFC automatic frequency selection)
Display Mode2.5-inch color LCD screen
Short Circuit Test CurrentAC 10mA max
Open Circuit Test VoltageAC 14V max
Electrode Spacing Range1m~100m
Weight5.1 kg
Clamp Size65mm×32mm
Tester Size307mm×98mm×56mm
Test Line4 Pieces (red 20m, black 20m, yellow 10m, green 10m)
Simple Test Line2 Pieces (red 1.6m, black 1.6m)
Auxiliary Ground Rod4*Φ9mm×230mm (935g)
Measurement Timesmore than 5000 times (short circuit test, test once, stop for 30 seconds and test again)
Line Voltagemeasured below AC 600V
Data Memory500 groups
Audible And Visible Alarm"du—du—du" for alarming, press AL to turn on/off
Automatic Shut-DownAutomatic shutdown after 5 minutes of power on
ShiftAutomatically
External Magnet/Electric Field< 40A/m, < 1V/m
Resistance Test Frequency>1KHz, 128Hz
InterfaceUSB interface
AccessoriesResistance Tester: 1PCS; Test Loop:1PCS; Test Ring: 1PCS; USB Charging Cable:1PCS; Charger: 1PCS; Ground Pin: 4PCS; Test Leads: 4PCS; Simple Test Leads: 2PCS; Tool Box: 1PCS


Range and Accuracy

Measuring FunctionMeasuring RangeAccuracyResolution
Measuring Grounding Resistance with Clamp Meter0.010Ω~0.099Ω±(1%rdg+0.05Ω)0.001Ω
0.10Ω~0.99Ω±(1%rdg+0.05Ω)0.01Ω
1.0Ω~49.9Ω±(1%rdg+0.5Ω)0.1Ω
50.0Ω~99.5Ω±(2%rdg+0.5Ω)0.5Ω
100Ω~199Ω±(5%rdg+1Ω)1Ω
Two-Three-Four-Wire Method for Measuring Grounding Resistance0.10Ω~20.00Ω±2%rdg±5dgt0.01Ω
20.0Ω~200.0Ω±2%rdg±5dgt0.1Ω
200Ω~2000Ω±2%rdg±5dgt1Ω
2.00kΩ~20.00kΩ±4%rdg±5dgt10Ω
Selective Method for measuring grounding resistance0.10Ω~20.00Ω±2%rdg±5dgt0.01Ω
20.0Ω~200.0Ω±2%rdg±5dgt0.1Ω
200Ω~2000Ω±2%rdg±5dgt1Ω
Soil Resistivity0.00Ωm~99.99ΩmDepends on the measurement accuracy of the R
(ρ=2πaR
a:1m~100m;
π=3.14)
0.01Ωm
100.0Ωm~999.9Ωm0.1Ωm
1000Ωm~9999Ωm1Ωm
10.00kΩm~99.99k10Ωm
100.0kΩm~999.9k100Ωm
1000kΩm~9999kΩmπ=3.14)1kΩm
Ground Voltage 50Hz/60HzAC 0.0~600.0V±2%rdg±5dgt0.1V
Ground Current 50Hz/60Hz0.000mA~5.000mA±(2.5%rdg+1mA)0.001mA
5.0mA~100.0mA±(2.5%rdg+5mA)0.1mA
100mA~500mA±(2.5%rdg+10mA)1mA
0.50A~20.00A±(2.5%rdg+0.5A)0.01A
*20.0A~45.0A±(2.5%rdg+0.5A)0.1A

Note

  • The additional error when rC max or rP max is ≤±5%rdg±5dgt.
  • rC max: 4kΩ+100R<50kΩ, rP max: 4kΩ+100R<50kΩ
  • The additional error at 2.5V interference voltage is ≤±5%rdg±5dgt.

Details

Clamp earth resistance tester details

Applications

ATO provides earth resistance testers with a measurement range of 0.00Ω-300kΩ, which are widely used in ground resistance measurement and loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil fields, construction, and industrial electrical equipment. When measuring the grounding system with a loop, the ground resistance tester does not need auxiliary electrodes and does not need to disconnect the grounding wire, which is safer and faster.

Clamp earth resistance tester applicationsTips: What are the factors that affect soil resistivity?

  • Soil resistivity is the average value of soil resistance per unit length, measured in ohm meters. The main factors affecting soil resistivity are as follows:
  • Different soil types have different soil resistivities.
    When the temperature drops again, ρ increases significantly. As the temperature starts to rise from 0°C, ρ will only decrease steadily.
  • The size of the soil resistivity ρ mainly depends on the concentration of conductive ions in the soil and the water content in the soil. The higher the concentration of conductive ions in the soil, the better the conductivity of the soil and the smaller ρ.
  • The density of the soil affects the soil resistivity.
  • Seasonal changes will cause changes in soil resistivity, and the most obvious factors affecting soil resistivity are rainfall and freezing.