Clamp Ground Resistance Tester, 0.010Ω to 1500Ω

$998.50
High precision clamp-on ground resistance tester is designed for ground resistance measurement, loop resistance measurement, grounding down leads leakage current measurement and judging ground fault. Digital earth testing meter provides a 0.010Ω~1500Ω measurement range, 0.00mA~40.0A current range, sound and light alarm, data storage and data retention function, which is your better choice to measure your ground resistance.
SKU: ATO-ERT-1500
Free Shipping
Delivery date: 6-12 days

The provided digital earth resistance tester features a 0.010Ω~1500Ω measurement range, 0.00mA~40.0A current range, sound and light alarm function, data storage function and data retention function. Clamp-on ground resistance tester is suitable for measuring the grounding resistance of various equipment. It can also be used for loop resistance measurement, grounding down leads leakage current measurement and judging ground fault.

Features

  • Digital earth resistance tester is a high-quality ground resistance tester, available with a 32mm clamp and 0.010Ω~1500Ω measure range.
  • Ground resistance tester is a non-contact measurement, which is safe and fast. When measuring the loop grounding system, there is no need to disconnect the grounding lead and the auxiliary grounding electrode.
  • The clamp ground resistance tester can measure ground faults that cannot be measured by traditional methods and is suitable for occasions where traditional methods cannot be used.
  • ATO earth testing meter has the functions of sound and light alarm, data storage, data retention and so on. LCD clearly displays the measurement data in high definition, and the data can be displayed in a backlight.

Specifications

ModelATO-ERT-2200
Resistance Range0.010Ω~1500Ω
Current Range0.00mA~40.0A
Current Resolution1 uA
Resistance Resolution0.010Ω
Weight2.5 kg
Clamp Size65mm×32mm
Tester Size295mm×98mm×66mm
Current Test Accuracy±(1.5%rdg+0.5mA)
Power SupplyRechargeable lithium battery DC 3.7V 2600mAh
Single Measurement Time0.5 second
LCD Screen4 Digits LCD display,  47mm×28.5mm
Data Memory99 groups
Audible And Visible Alarm"du—du—du" for alarming, press AL to turn on/off
Alarm Threshold Setting RangeResistance: 1-199Ω, Current: 1-499mA
ShiftAutomatically
External Magnet/Electric Field< 40A/m, < 1V/m
Resistance Test Frequency1KHz
AccessoriesResistance Tester: 1PCS; Test Ring: 1PCS; Instrument Case: 1PCS
InterfaceUSB interface, Software monitoring, Data upload computer
AccessoriesResistance Tester: 1PCS, Test ring: 1PCS, USB data cable I charge cable: 1PCS, Charger. 1PCS, Instrument Case: 1PCS
Clamp Meter WeightAbout 1230g (including battery)


Resistance Measurement Accuracy

RangeResolutionAccuracy
0.010Ω-0.099Ω0.001Ω±(1%rdg+0.01Ω)
0.10Ω-0.99Ω0.01Ω±(1%rdg+0.01Ω)
1.0Ω-49.9Ω0.1Ω±(1%rdg+0.12)
50.0Ω-99.5Ω0.5Ω±(1.5%rdg+0.5)
100Ω-199Ω1Ω±(2%rdg+1Ω)
200Ω-395Ω5Ω±(5%rdg+5Ω
400-590Ω10Ω±(10%rdg+10Ω)
600Ω-880Ω20Ω±(20%rdg+20Ω)
900Ω-1500Ω30Ω±(25%rdg+30Ω)


Current Measurement Accuracy

RangeResolutionAccuracy
0.00mA-90.999mA0.001mA±(1.5%rdg+0.5mA)
0.00mA-9.95mA0.01mA±(2%rdg+1mA)
10.0mA-99.0mA0.1mA±(2.5%rdg+5mA)
0.30A-2.99A0.01A±(2.5%rdg+0.1A)
3.0A-9.9A0.1 A±(2.5%rdg+0.3A)
10.0A-20.0A0.1A±(2.5%rdg+0.5A)
20.0A-40.0A0.1 A±(3%rdg+1A)

Details

Clamp Ground Resistance Tester Details
Applications

ATO provides earth resistance testers with a measurement range of 0.00Ω-300kΩ, which are widely used in ground resistance measurement and loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil fields, construction, and industrial electrical equipment. When measuring the grounding system with a loop, the ground resistance tester does not need auxiliary electrodes and does not need to disconnect the grounding wire, which is safer and faster.

Clamp ground resistance tester applications4 Tips for Measuring Ground Resistance

  • When measuring ground resistance with an AC power supply, an independent power supply, usually a separate transformer, should be used, and the neutral point and grounding point should be open to prevent errors caused by shunting or current failure. The voltage level is estimated based on the current loop impedance and the required current.
  • In many substations, the overhead ground wire of the transmission line is connected with the grounding device of the substation, which will affect the measurement results of the ground resistance of the grounding device of the substation. The lightning conductor of the line is disconnected from the electrical connection of the grounding device of the substation.
  • Because a large current needs to be injected into the current pole, it will cause harm to nearby people and animals. Therefore, special personnel must be supervised during the earth resistance measurement.
  • During the test, the current leadership must flow a larger current, therefore, the current loop must have a larger wire cross-section.
Product reviews
Easy measurement process
5
Cack
Avatar
8/1/2024 12:20 AM
I recently purchased this Clamp Ground Resistance Tester and I am very satisfied with the performance of this tester. The clamp design of the tester makes the measurement process very easy. There is no need to disconnect the circuit, just clamp the test clip to measure, which greatly saves operation time and energy.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The provided digital earth resistance tester features a 0.010Ω~1500Ω measurement range, 0.00mA~40.0A current range, sound and light alarm function, data storage function and data retention function. Clamp-on ground resistance tester is suitable for measuring the grounding resistance of various equipment. It can also be used for loop resistance measurement, grounding down leads leakage current measurement and judging ground fault.

Features

  • Digital earth resistance tester is a high-quality ground resistance tester, available with a 32mm clamp and 0.010Ω~1500Ω measure range.
  • Ground resistance tester is a non-contact measurement, which is safe and fast. When measuring the loop grounding system, there is no need to disconnect the grounding lead and the auxiliary grounding electrode.
  • The clamp ground resistance tester can measure ground faults that cannot be measured by traditional methods and is suitable for occasions where traditional methods cannot be used.
  • ATO earth testing meter has the functions of sound and light alarm, data storage, data retention and so on. LCD clearly displays the measurement data in high definition, and the data can be displayed in a backlight.

Specifications

ModelATO-ERT-2200
Resistance Range0.010Ω~1500Ω
Current Range0.00mA~40.0A
Current Resolution1 uA
Resistance Resolution0.010Ω
Weight2.5 kg
Clamp Size65mm×32mm
Tester Size295mm×98mm×66mm
Current Test Accuracy±(1.5%rdg+0.5mA)
Power SupplyRechargeable lithium battery DC 3.7V 2600mAh
Single Measurement Time0.5 second
LCD Screen4 Digits LCD display,  47mm×28.5mm
Data Memory99 groups
Audible And Visible Alarm"du—du—du" for alarming, press AL to turn on/off
Alarm Threshold Setting RangeResistance: 1-199Ω, Current: 1-499mA
ShiftAutomatically
External Magnet/Electric Field< 40A/m, < 1V/m
Resistance Test Frequency1KHz
AccessoriesResistance Tester: 1PCS; Test Ring: 1PCS; Instrument Case: 1PCS
InterfaceUSB interface, Software monitoring, Data upload computer
AccessoriesResistance Tester: 1PCS, Test ring: 1PCS, USB data cable I charge cable: 1PCS, Charger. 1PCS, Instrument Case: 1PCS
Clamp Meter WeightAbout 1230g (including battery)


Resistance Measurement Accuracy

RangeResolutionAccuracy
0.010Ω-0.099Ω0.001Ω±(1%rdg+0.01Ω)
0.10Ω-0.99Ω0.01Ω±(1%rdg+0.01Ω)
1.0Ω-49.9Ω0.1Ω±(1%rdg+0.12)
50.0Ω-99.5Ω0.5Ω±(1.5%rdg+0.5)
100Ω-199Ω1Ω±(2%rdg+1Ω)
200Ω-395Ω5Ω±(5%rdg+5Ω
400-590Ω10Ω±(10%rdg+10Ω)
600Ω-880Ω20Ω±(20%rdg+20Ω)
900Ω-1500Ω30Ω±(25%rdg+30Ω)


Current Measurement Accuracy

RangeResolutionAccuracy
0.00mA-90.999mA0.001mA±(1.5%rdg+0.5mA)
0.00mA-9.95mA0.01mA±(2%rdg+1mA)
10.0mA-99.0mA0.1mA±(2.5%rdg+5mA)
0.30A-2.99A0.01A±(2.5%rdg+0.1A)
3.0A-9.9A0.1 A±(2.5%rdg+0.3A)
10.0A-20.0A0.1A±(2.5%rdg+0.5A)
20.0A-40.0A0.1 A±(3%rdg+1A)

Details

Clamp Ground Resistance Tester Details
Applications

ATO provides earth resistance testers with a measurement range of 0.00Ω-300kΩ, which are widely used in ground resistance measurement and loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil fields, construction, and industrial electrical equipment. When measuring the grounding system with a loop, the ground resistance tester does not need auxiliary electrodes and does not need to disconnect the grounding wire, which is safer and faster.

Clamp ground resistance tester applications4 Tips for Measuring Ground Resistance

  • When measuring ground resistance with an AC power supply, an independent power supply, usually a separate transformer, should be used, and the neutral point and grounding point should be open to prevent errors caused by shunting or current failure. The voltage level is estimated based on the current loop impedance and the required current.
  • In many substations, the overhead ground wire of the transmission line is connected with the grounding device of the substation, which will affect the measurement results of the ground resistance of the grounding device of the substation. The lightning conductor of the line is disconnected from the electrical connection of the grounding device of the substation.
  • Because a large current needs to be injected into the current pole, it will cause harm to nearby people and animals. Therefore, special personnel must be supervised during the earth resistance measurement.
  • During the test, the current leadership must flow a larger current, therefore, the current loop must have a larger wire cross-section.
Product reviews
Easy measurement process
5
Cack
Avatar
8/1/2024 12:20 AM
I recently purchased this Clamp Ground Resistance Tester and I am very satisfied with the performance of this tester. The clamp design of the tester makes the measurement process very easy. There is no need to disconnect the circuit, just clamp the test clip to measure, which greatly saves operation time and energy.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews