Embedded Concrete Strain Gauge

$16.36
Embedded strain gauges for precise measurement of true internal strain in concrete. Constructed with waterproof composite materials for moisture resistance and corrosion protection, ensuring long-term stability and reliability. Built-in temperature compensation ensures data accuracy.High sensitivity with 3.2mm shielded cable for stable, anti-interference signal transmission.
SKU: ATO-SG-EC
This product has a minimum quantity of 10
Free Shipping
Delivery date: 6-12 days

This embedded concrete strain gauge features a polyimide substrate for exceptional durability. Standard resistance values of 120Ω(±0.8%) and gauge lengths of 80mm are available, both customizable to meet diverse engineering requirements. The operating temperature range extends from -30°C to +60°C, meeting the demands of typical engineering environments.

Specification

ModelATO-TMB120-80AA3L2
Standard Resistance120 Ω ±0.8% (other resistance values available upon request)
SubstratePolyimide
Operating Temperature Range-5℃ ~ 50℃
Extreme Temperature Range-30℃ ~ +60℃
Product StructureStrain-sensitive grid encapsulated and sealed with robust waterproof composite material
External MaterialSpecial polymer composite material
Structure Dimensions130 × 17 × 10 mm
Sensitive Grid MaterialConstantan / Karma alloy sensitive grid (manufactured according to application requirements)
Sensitive Grid Length80 mm (customizable)


Features

  1. Temperature Self-Compensation: Built-in temperature compensation minimizes the impact of ambient temperature fluctuations, ensuring this strain gauge delivers stable and accurate performance in embedded concrete applications.
  2. Waterproof and Corrosion Resistance: Constructed with specialized polymer composite materials, this waterproof concrete strain gauge resists moisture penetration and corrosion, making it ideal for long-term embedded strain gauge installations in harsh environments.
  3. Stable and Interference-Resistant: Equipped with a high-sensitivity resistance strain gauge element and a 3.2mm outer-diameter shielded cable, this embedded strain gauge provides stable signal transmission and enhanced anti-interference capability for reliable structural monitoring.

Tips: How to select the right strain gauge for your needs?

To choose the appropriate strain gauge, first clarify the measurement objectives and operating environment, then match parameters based on specific working conditions. First, determine the suitable type based on the measurement purpose, temperature range, and environmental conditions. Next, select the grid length according to the uniformity and curvature of the material being measured. Match the temperature self-compensation specification to the thermal expansion coefficient of the component being measured. Choose the resistance based on the measurement circuit and power consumption requirements. Determine the sensitive grid and substrate materials considering the operating temperature, durability, and installation conditions, while ensuring the strain range covers the actual maximum strain and includes a safety margin. Finally, select the grid pattern and lead configuration based on strain type, wiring distance, and anti-interference requirements. Integrating these parameters enables the selection of strain gauges meeting measurement accuracy, stability, and reliability requirements.

Product reviews
Reliable for long-term use
5
Bob
Avatar
4/2/2026 6:51 PM
We installed this strain gauge in bridge concrete. Waterproof sealing is excellent, signal stays stable with temperature compensation.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

This embedded concrete strain gauge features a polyimide substrate for exceptional durability. Standard resistance values of 120Ω(±0.8%) and gauge lengths of 80mm are available, both customizable to meet diverse engineering requirements. The operating temperature range extends from -30°C to +60°C, meeting the demands of typical engineering environments.

Specification

ModelATO-TMB120-80AA3L2
Standard Resistance120 Ω ±0.8% (other resistance values available upon request)
SubstratePolyimide
Operating Temperature Range-5℃ ~ 50℃
Extreme Temperature Range-30℃ ~ +60℃
Product StructureStrain-sensitive grid encapsulated and sealed with robust waterproof composite material
External MaterialSpecial polymer composite material
Structure Dimensions130 × 17 × 10 mm
Sensitive Grid MaterialConstantan / Karma alloy sensitive grid (manufactured according to application requirements)
Sensitive Grid Length80 mm (customizable)


Features

  1. Temperature Self-Compensation: Built-in temperature compensation minimizes the impact of ambient temperature fluctuations, ensuring this strain gauge delivers stable and accurate performance in embedded concrete applications.
  2. Waterproof and Corrosion Resistance: Constructed with specialized polymer composite materials, this waterproof concrete strain gauge resists moisture penetration and corrosion, making it ideal for long-term embedded strain gauge installations in harsh environments.
  3. Stable and Interference-Resistant: Equipped with a high-sensitivity resistance strain gauge element and a 3.2mm outer-diameter shielded cable, this embedded strain gauge provides stable signal transmission and enhanced anti-interference capability for reliable structural monitoring.

Tips: How to select the right strain gauge for your needs?

To choose the appropriate strain gauge, first clarify the measurement objectives and operating environment, then match parameters based on specific working conditions. First, determine the suitable type based on the measurement purpose, temperature range, and environmental conditions. Next, select the grid length according to the uniformity and curvature of the material being measured. Match the temperature self-compensation specification to the thermal expansion coefficient of the component being measured. Choose the resistance based on the measurement circuit and power consumption requirements. Determine the sensitive grid and substrate materials considering the operating temperature, durability, and installation conditions, while ensuring the strain range covers the actual maximum strain and includes a safety margin. Finally, select the grid pattern and lead configuration based on strain type, wiring distance, and anti-interference requirements. Integrating these parameters enables the selection of strain gauges meeting measurement accuracy, stability, and reliability requirements.

Product reviews
Reliable for long-term use
5
Bob
Avatar
4/2/2026 6:51 PM
We installed this strain gauge in bridge concrete. Waterproof sealing is excellent, signal stays stable with temperature compensation.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Mini Concrete Strain Gauge

ATO-SG-50AA
$5.60
The mini concrete strain gauge combines a constantan sensing grid with a phenolic-epoxy base to deliver highly accurate measurements with 120ohm resistance and ±0.01% precision. Designed for operation from -30°C to 60°C, this sensor supports reliable monitoring of concrete structures.