Biaxial High Temperature Strain Gauge

$28.12
Biaxial high temperature strain gauge employs solderless crimp connection technology, featuring integrated leads that crimp directly to test leads for testing without soldering. Supporting an ultra-wide temperature range of -200℃ to +250℃ and a strain capacity up to 20,000με, this strain gauge incorporates a 0–90° dual-axis structure. A single installation enables bidirectional strain measurement.
SKU: ATO-SG-BHT
This product has a minimum quantity of 20
Free Shipping
Delivery date: 6-12 days

Biaxial high temp strain gauges are specifically designed for high-temperature and complex load testing scenarios. Combining a highly stable adhesive-based structure with precision strain grid technology, this industrial strain gauge deliver high-accuracy output and long-term reliability, making them suitable for both scientific research and industrial-grade strain analysis.

Specification

ModelATO-BAB120-3BA
Resistance120 Ω
Gauge Factor1.83
Accuracy ClassClass A
Sensitive Grid Dimensions3*2.5mm
Base MaterialGelatinous base
Base Dimensions12*12mm
Measuring Range20000 με
Operating Temperature Range-200℃ to 250℃
Lead Wire Length2m high-temperature lead wire (Customizable)


Features

  1. Solderless Design: The strain gauge's integrated leads and test cables connect via crimping, eliminating any soldering and significantly improving wiring efficiency.
  2. Extreme Temperature Range: Designed as a high temperature strain gauge, it operates from -200℃ to +250℃, ensuring stable performance in cryogenic and elevated-temperature structural testing.
  3. 0-90° Biaxial Axis Design: This biaxial strain gauge enables dual-direction strain measurement with one installation, improving accuracy and efficiency in stress analysis and structural health monitoring.
  4. Wide Measurement Range: As a precision resistive strain gauge, it offers a measurement range up to 20,000 με, making it suitable for both elastic and plastic deformation testing.

Tips: What's the difference between high temperature strain gauge and ordinary strain gauge?

High-temperature strain gauges and standard strain gauges appear similar in form, but from the sensitive grid material, substrate, adhesive, and leads to stability, they are all redesigned for high-temperature resistance. Standard strain gauges typically employ constantan alloy and polyimide adhesive substrates, with a typical temperature range of -30°C to +80°C. At higher temperatures, substrate softening, resistance drift, and adhesive failure occur, leading to measurement inaccuracies or even damage. High-temperature strain gauges, however, employ high-temperature alloys like Kama, platinum-tungsten, or Invar for the sensing grid. They incorporate heat-resistant adhesive bases, inorganic substrates, or ceramic substrates, paired with specialized high-temperature bonding adhesives and conductors. enabling operation at 200°C, 400°C, or even higher temperatures. They exhibit lower thermal output, reduced creep, and superior thermal stability, ensuring reliable measurements in harsh environments like engines, metallurgy, and high-temperature pipelines without accuracy degradation or structural failure due to heat.

Product reviews
Accurate data, reliable performance
5
Sam
Avatar
3/24/2026 7:29 PM
This strain gauge performs reliably on our steam pipe at 250°C. Measuring two directions with a single application, saving time.  And the data is consistently accurate.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Biaxial high temp strain gauges are specifically designed for high-temperature and complex load testing scenarios. Combining a highly stable adhesive-based structure with precision strain grid technology, this industrial strain gauge deliver high-accuracy output and long-term reliability, making them suitable for both scientific research and industrial-grade strain analysis.

Specification

ModelATO-BAB120-3BA
Resistance120 Ω
Gauge Factor1.83
Accuracy ClassClass A
Sensitive Grid Dimensions3*2.5mm
Base MaterialGelatinous base
Base Dimensions12*12mm
Measuring Range20000 με
Operating Temperature Range-200℃ to 250℃
Lead Wire Length2m high-temperature lead wire (Customizable)


Features

  1. Solderless Design: The strain gauge's integrated leads and test cables connect via crimping, eliminating any soldering and significantly improving wiring efficiency.
  2. Extreme Temperature Range: Designed as a high temperature strain gauge, it operates from -200℃ to +250℃, ensuring stable performance in cryogenic and elevated-temperature structural testing.
  3. 0-90° Biaxial Axis Design: This biaxial strain gauge enables dual-direction strain measurement with one installation, improving accuracy and efficiency in stress analysis and structural health monitoring.
  4. Wide Measurement Range: As a precision resistive strain gauge, it offers a measurement range up to 20,000 με, making it suitable for both elastic and plastic deformation testing.

Tips: What's the difference between high temperature strain gauge and ordinary strain gauge?

High-temperature strain gauges and standard strain gauges appear similar in form, but from the sensitive grid material, substrate, adhesive, and leads to stability, they are all redesigned for high-temperature resistance. Standard strain gauges typically employ constantan alloy and polyimide adhesive substrates, with a typical temperature range of -30°C to +80°C. At higher temperatures, substrate softening, resistance drift, and adhesive failure occur, leading to measurement inaccuracies or even damage. High-temperature strain gauges, however, employ high-temperature alloys like Kama, platinum-tungsten, or Invar for the sensing grid. They incorporate heat-resistant adhesive bases, inorganic substrates, or ceramic substrates, paired with specialized high-temperature bonding adhesives and conductors. enabling operation at 200°C, 400°C, or even higher temperatures. They exhibit lower thermal output, reduced creep, and superior thermal stability, ensuring reliable measurements in harsh environments like engines, metallurgy, and high-temperature pipelines without accuracy degradation or structural failure due to heat.

Product reviews
Accurate data, reliable performance
5
Sam
Avatar
3/24/2026 7:29 PM
This strain gauge performs reliably on our steam pipe at 250°C. Measuring two directions with a single application, saving time.  And the data is consistently accurate.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews