30-60 HP Vertical Multistage Centrifugal Pump, 3 Phase, DN125 Outlet

$10,182.27
Vertical multistage pump price is reasonable and cost-effective. The inside impeller, casing and other main components are all stainless steel punched. The impeller of DN125 vertical multistage pump has accurate profile, smooth flow channel and good balance. This vertical multistage centrifugal pump has 3 kinds of power: 30hp, 40hp and 60hp. Stainless steel multistage centrifugal pump often used in booster system, industrial processes, wastewater treatment and desalination plant.
SKU: ATO-VMCP-125
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

A vertical multistage centrifugal water pump is a type of pump used to move fluids, typically water, from one location to another. DN125 vertical multi stage centrifugal pump is designed to generate high-pressure output by utilizing multiple stages of impellers and diffusers stacked vertically within the pump casing.

Features:

  • Excellent hydraulic model and advanced manufacturing technology, greatly improve the performance and service life of the pump.
  • Mechanical seals made using hard alloy and fluorine rubber, improve the reliability of operation and the temperature of the transport medium.
  • Compact structure, small size, lightweight, low noise, significant energy-saving effect, convenient maintenance.
  • The inlet and outlet of the pump are located on the same level and can be directly used in the pipeline.

Specification:

ModelATO-125CDLF
Materialstainless steel
Motor100% copper wire, full power
Moter Voltage3 phase 380V-415V (single phase 220V for 2.2 kW or less); other voltages, contact us
Frequency50 Hz
Impellervortex impeller
Outlet DiameterDN125
Flow Rate120m3/h
Power22 kW (30 HP); 30 kW (40 HP); 45 kW (60 HP)
Head40m; 61m; 90m
Net Weight285kg; 360kg; 470kg
Waterproof GradeIP55
CertificationCE


Structure:

Vertical multistage centrifugal pump structure

Mounting Dimension (Unit: mm)

Vertical multistage centrifugal pump dn125 dimension

ModelB1B2B1+B2D1D2
CDLF120-20 (22kW)10005751575360285
CDLF120-30 (30kW)11606501810400310
CDLF120-50-2 (45kW)14806852165460340

Tips: Vertical Multistage Centrifugal Pump Troubleshooting

  • Check Power Supply. Ensure that the pump is receiving the correct power supply voltage and frequency. Check for blown fuses, tripped circuit breakers, or other electrical issues.
  • Check Motor Operation. Verify that the motor is running properly and not overheating. Check for any unusual noises, vibrations, or excessive heat from the motor.
  • Inspect Pressure Gauges. Check the pressure gauges on the pump to ensure that they are functioning correctly. Compare the readings with the desired pressure levels.
  • Check Suction and Discharge Lines. Make sure that the suction and discharge lines are free from blockages or obstructions. Check for leaks, cracks, or damage in the piping system.
  • Inspect Impellers and Diffusers. Open the pump casing and inspect the impellers and diffusers for wear, damage, or clogs. Clean or replace any components that are worn out or obstructed.

Different types of centrifugal pumps

This video explains different types of centrifugal pumps that can be selected according to one's own needs.

Principles and functionality explained

This video tells us what a centrifugal pump is and its working principle, and you will have a general understanding of it.

Components of centrifugal pumps

This video is an explanation of the components of a centrifugal pump, and we can learn the basic knowledge of the eight components of a centrifugal pump from it.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Outstanding Performance
5
Jocob
Avatar
8/30/2023 7:43 PM
The DN125 Vertical Multistage Centrifugal Pump has left an indelible mark with its impeccable performance. This pump's ability to efficiently handle various liquids, from water to chemicals, showcases its remarkable versatility. Its vertical design optimizes space utilization while maintaining powerful pumping capabilities. The precision engineering ensures quiet operation and minimal maintenance, making it a reliable asset.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

A vertical multistage centrifugal water pump is a type of pump used to move fluids, typically water, from one location to another. DN125 vertical multi stage centrifugal pump is designed to generate high-pressure output by utilizing multiple stages of impellers and diffusers stacked vertically within the pump casing.

Features:

  • Excellent hydraulic model and advanced manufacturing technology, greatly improve the performance and service life of the pump.
  • Mechanical seals made using hard alloy and fluorine rubber, improve the reliability of operation and the temperature of the transport medium.
  • Compact structure, small size, lightweight, low noise, significant energy-saving effect, convenient maintenance.
  • The inlet and outlet of the pump are located on the same level and can be directly used in the pipeline.

Specification:

ModelATO-125CDLF
Materialstainless steel
Motor100% copper wire, full power
Moter Voltage3 phase 380V-415V (single phase 220V for 2.2 kW or less); other voltages, contact us
Frequency50 Hz
Impellervortex impeller
Outlet DiameterDN125
Flow Rate120m3/h
Power22 kW (30 HP); 30 kW (40 HP); 45 kW (60 HP)
Head40m; 61m; 90m
Net Weight285kg; 360kg; 470kg
Waterproof GradeIP55
CertificationCE


Structure:

Vertical multistage centrifugal pump structure

Mounting Dimension (Unit: mm)

Vertical multistage centrifugal pump dn125 dimension

ModelB1B2B1+B2D1D2
CDLF120-20 (22kW)10005751575360285
CDLF120-30 (30kW)11606501810400310
CDLF120-50-2 (45kW)14806852165460340

Tips: Vertical Multistage Centrifugal Pump Troubleshooting

  • Check Power Supply. Ensure that the pump is receiving the correct power supply voltage and frequency. Check for blown fuses, tripped circuit breakers, or other electrical issues.
  • Check Motor Operation. Verify that the motor is running properly and not overheating. Check for any unusual noises, vibrations, or excessive heat from the motor.
  • Inspect Pressure Gauges. Check the pressure gauges on the pump to ensure that they are functioning correctly. Compare the readings with the desired pressure levels.
  • Check Suction and Discharge Lines. Make sure that the suction and discharge lines are free from blockages or obstructions. Check for leaks, cracks, or damage in the piping system.
  • Inspect Impellers and Diffusers. Open the pump casing and inspect the impellers and diffusers for wear, damage, or clogs. Clean or replace any components that are worn out or obstructed.
Product reviews
Outstanding Performance
5
Jocob
Avatar
8/30/2023 7:43 PM
The DN125 Vertical Multistage Centrifugal Pump has left an indelible mark with its impeccable performance. This pump's ability to efficiently handle various liquids, from water to chemicals, showcases its remarkable versatility. Its vertical design optimizes space utilization while maintaining powerful pumping capabilities. The precision engineering ensures quiet operation and minimal maintenance, making it a reliable asset.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews