2-4 HP Vertical Multistage Centrifugal Pump, 3 Phase, DN32 Outlet

$2,078.89
Centrifugal vertical multistage pump with DN32 outlet diameter and 380V voltage. Vertical multistage centrifugal pump price is affordable. The waterproof grade of vertical multistage water pump is IP55. This vertical multistage centrifugal pump has 3 kinds of power: 2hp, 3hp and 4hp. Vertical multistage pump can meet the requirements of water supply, food and pharmaceutical industry.
SKU: ATO-VMCP-32
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

Unlike single-stage centrifugal pumps, which have only one impeller, the multistage design incorporates multiple impellers stacked vertically within the pump casing. Each impeller is connected to a common shaft, and the DN32 outlet 2-4hp vertical multistage water pump is typically driven by an electric motor.

Features:

  • Excellent hydraulic model and advanced manufacturing technology, greatly improve the performance and service life of the pump.
  • Mechanical seals made of using hard alloy and fluorine rubber, improving the reliability of operation and the temperature of the transport medium.
  • Compact structure, small size, lightweight, low noise, significant energy-saving effect, convenient maintenance.
  • The inlet and outlet of the pump are located on the same level and can be directly used in the pipeline.

Specification:

ModelATO-32CDLF
Materialstainless steel
Motor100% copper wire, full power
Moter Voltage3 phase 380V-415V (single phase 220V for 2.2 kW or less); other voltages, contact us
Frequency50 Hz
Impellervortex impeller
Outlet DiameterDN32
Flow Rate4m3/h
Power1.5 kW (2 HP); 2.2 kW (3 HP); 3 kW (4 HP)
Head64m; 81m, 95m; 112m
Net Weight33kg; 37kg, 38kg; 46kg
Waterproof GradeIP55
CertificationCE


Structure:

Vertical multistage centrifugal pump structure

Mounting Dimension (Unit: mm)

Vertical multistage centrifugal pump dn32 dimension

ModelB1B2B1+B2D1D2
CDLF4-8--32CDL(F)4-80 (1.5kW)458290748190155
CDLF4-10--32CDL(F)4-100 (2.2kW)512290802190155
CDLF4-12--32CDL(F)4-120 (2.2kW)566290856190155
CDLF4-14--32CDL(F)4-140 (3kW)630345975197165

Tips: How to Maintain Vertical Multistage Centrifugal Pump?

  • Regular Inspection. Check for leaks, unusual vibrations, and excessive noise during operation.
  • Lubrication. Ensure proper lubrication of bearings and mechanical seals as per manufacturer's recommendations.
  • Impeller Inspection. Inspect impellers for wear or damage, and replace if necessary to maintain efficiency.
  • Shaft Alignment. Regularly check and adjust shaft alignment to prevent premature wear and vibrations.
  • Seals and Gaskets. Monitor and replace seals and gaskets if they show signs of leakage or wear.
  • Motor Maintenance. Maintain the motor by checking connections, cleaning, and servicing according to manufacturer guidelines.
  • Cleaning. Regularly clean the pump and its components to prevent clogs and buildup.
  • Monitor Performance. Track pump performance using pressure and flow measurements to identify deviations from normal operation.
  • Vibration Analysis. Perform vibration analysis to detect any issues with the pump's internal components.

Different types of centrifugal pumps

This video explains different types of centrifugal pumps that can be selected according to one's own needs.

Principles and functionality explained

This video tells us what a centrifugal pump is and its working principle, and you will have a general understanding of it.

Components of centrifugal pumps

This video is an explanation of the components of a centrifugal pump, and we can learn the basic knowledge of the eight components of a centrifugal pump from it.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Efficient vertical pump
5
Amari
Avatar
10/29/2026 8:00 PM
Picked this vertical multistage pump for our pharmaceutical process. The inline layout made installation quick and easy. It maintains consistent pressure while using less power, and it’s simple to access for routine maintenance.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Unlike single-stage centrifugal pumps, which have only one impeller, the multistage design incorporates multiple impellers stacked vertically within the pump casing. Each impeller is connected to a common shaft, and the DN32 outlet 2-4hp vertical multistage water pump is typically driven by an electric motor.

Features:

  • Excellent hydraulic model and advanced manufacturing technology, greatly improve the performance and service life of the pump.
  • Mechanical seals made of using hard alloy and fluorine rubber, improving the reliability of operation and the temperature of the transport medium.
  • Compact structure, small size, lightweight, low noise, significant energy-saving effect, convenient maintenance.
  • The inlet and outlet of the pump are located on the same level and can be directly used in the pipeline.

Specification:

ModelATO-32CDLF
Materialstainless steel
Motor100% copper wire, full power
Moter Voltage3 phase 380V-415V (single phase 220V for 2.2 kW or less); other voltages, contact us
Frequency50 Hz
Impellervortex impeller
Outlet DiameterDN32
Flow Rate4m3/h
Power1.5 kW (2 HP); 2.2 kW (3 HP); 3 kW (4 HP)
Head64m; 81m, 95m; 112m
Net Weight33kg; 37kg, 38kg; 46kg
Waterproof GradeIP55
CertificationCE


Structure:

Vertical multistage centrifugal pump structure

Mounting Dimension (Unit: mm)

Vertical multistage centrifugal pump dn32 dimension

ModelB1B2B1+B2D1D2
CDLF4-8--32CDL(F)4-80 (1.5kW)458290748190155
CDLF4-10--32CDL(F)4-100 (2.2kW)512290802190155
CDLF4-12--32CDL(F)4-120 (2.2kW)566290856190155
CDLF4-14--32CDL(F)4-140 (3kW)630345975197165

Tips: How to Maintain Vertical Multistage Centrifugal Pump?

  • Regular Inspection. Check for leaks, unusual vibrations, and excessive noise during operation.
  • Lubrication. Ensure proper lubrication of bearings and mechanical seals as per manufacturer's recommendations.
  • Impeller Inspection. Inspect impellers for wear or damage, and replace if necessary to maintain efficiency.
  • Shaft Alignment. Regularly check and adjust shaft alignment to prevent premature wear and vibrations.
  • Seals and Gaskets. Monitor and replace seals and gaskets if they show signs of leakage or wear.
  • Motor Maintenance. Maintain the motor by checking connections, cleaning, and servicing according to manufacturer guidelines.
  • Cleaning. Regularly clean the pump and its components to prevent clogs and buildup.
  • Monitor Performance. Track pump performance using pressure and flow measurements to identify deviations from normal operation.
  • Vibration Analysis. Perform vibration analysis to detect any issues with the pump's internal components.
Product reviews
Efficient vertical pump
5
Amari
Avatar
10/29/2026 8:00 PM
Picked this vertical multistage pump for our pharmaceutical process. The inline layout made installation quick and easy. It maintains consistent pressure while using less power, and it’s simple to access for routine maintenance.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews