Digital Panel Meter for DC Current Sensor, 4 Digit

$166.92
4-digit digital panel meter is designed for DC current sensors, adopts AC sampling technology, can directly or indirectly measure voltage and current in single-phase power grids.
SKU: ATO-DPM-PZ96B
*
*
Free Shipping
Delivery date: 6-12 days

Buy an ATO 4-digit display controller for DC current sensor. It is equipped with an RS-485 communication interface and Modbus-RTU protocol, providing analog outputs, relay alarm outputs, and digital input/output. Parameters such as ratio, alarm, and communication can be set and controlled via the keypad on the instrument panel to meet specific needs.

Specifications

ModelATO-PZ96B
Recommended Matching SensorATO-CUS-DC1500 (For other sensor models, please contact us.)
InputFrequency45~65Hz
VoltageRatings: AC 100V, 380V; DC 300V, 1000V
Overload: 1.2 times the rated value (continuous); 2 times the rated value or 1 second
Power Consumption: Less than 0.5VA
CurrentRatings: AC 1A, 5A; DC 75mV, 10V, 0-20mA, 4-20mA, 5A
Overload: 1.2 times the rated value (continuous); 10 times the rated value for 1 second
Power Consumption: Less than 0.5VA
OuputCommunicationRS485 interface, Modbus-RTU protocol
DisplayLED
FunctionSwitching (Input)4 dry contact inputs
Switching (Output)Output: 2 relay normally open contact outputs
Contact rating: AC meter capacity: 1A/30VDC or 1A/250VAC; DC meter capacity: 2A/30V DC or 2A/250VAC
Analog OutputOutput: 1 output, 0-20mA, 4-20mA programmable
Load capacity: ≤500Ω
Measurement AccuracyCurrent/voltage level 0.5
Power SupplyAC 85~265V or DC 100~350V; power consumption <5VA
Safety

Power frequency withstand voltage:

AC2kV 1min between power supply//switching output//current input//voltage input and transmitter//communication//switching input;
AC2kV 1min between power supply, switching output, current input, and voltage input;
AC1kV 1min between transmitter, communication, and switching input; Insulation resistance: input and output terminals to housing >100MΩ.

EnvironmentOperating temperature: -10℃~+55℃; Storage temperature: -25℃~+70℃; Relative humidity: ≤ 93%RH, non-condensing; Altitude: ≤2500m


Dimensions (Unit: mm)

Digital panel meter dimension

Tips: Why do DC current sensors need a digital panel meter?

A DC current sensor only converts the current into an electrical signal, such as a small voltage or current, but this signal by itself is not easy to read or understand. A digital panel meter is needed to take that sensor signal, scale it to the correct range, and display it as a clear numerical value in real time. This makes the measurement visible to operators, allows easy monitoring, and in some cases also provides alarm or control outputs for added functionality.

Product reviews
It offers professional-grade functionality
5
Sage
Avatar
1/4/2026 11:21 PM
Clear 4-digit display and stable readings. Works reliably with DC sensors.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Buy an ATO 4-digit display controller for DC current sensor. It is equipped with an RS-485 communication interface and Modbus-RTU protocol, providing analog outputs, relay alarm outputs, and digital input/output. Parameters such as ratio, alarm, and communication can be set and controlled via the keypad on the instrument panel to meet specific needs.

Specifications

ModelATO-PZ96B
Recommended Matching SensorATO-CUS-DC1500 (For other sensor models, please contact us.)
InputFrequency45~65Hz
VoltageRatings: AC 100V, 380V; DC 300V, 1000V
Overload: 1.2 times the rated value (continuous); 2 times the rated value or 1 second
Power Consumption: Less than 0.5VA
CurrentRatings: AC 1A, 5A; DC 75mV, 10V, 0-20mA, 4-20mA, 5A
Overload: 1.2 times the rated value (continuous); 10 times the rated value for 1 second
Power Consumption: Less than 0.5VA
OuputCommunicationRS485 interface, Modbus-RTU protocol
DisplayLED
FunctionSwitching (Input)4 dry contact inputs
Switching (Output)Output: 2 relay normally open contact outputs
Contact rating: AC meter capacity: 1A/30VDC or 1A/250VAC; DC meter capacity: 2A/30V DC or 2A/250VAC
Analog OutputOutput: 1 output, 0-20mA, 4-20mA programmable
Load capacity: ≤500Ω
Measurement AccuracyCurrent/voltage level 0.5
Power SupplyAC 85~265V or DC 100~350V; power consumption <5VA
Safety

Power frequency withstand voltage:

AC2kV 1min between power supply//switching output//current input//voltage input and transmitter//communication//switching input;
AC2kV 1min between power supply, switching output, current input, and voltage input;
AC1kV 1min between transmitter, communication, and switching input; Insulation resistance: input and output terminals to housing >100MΩ.

EnvironmentOperating temperature: -10℃~+55℃; Storage temperature: -25℃~+70℃; Relative humidity: ≤ 93%RH, non-condensing; Altitude: ≤2500m


Dimensions (Unit: mm)

Digital panel meter dimension

Tips: Why do DC current sensors need a digital panel meter?

A DC current sensor only converts the current into an electrical signal, such as a small voltage or current, but this signal by itself is not easy to read or understand. A digital panel meter is needed to take that sensor signal, scale it to the correct range, and display it as a clear numerical value in real time. This makes the measurement visible to operators, allows easy monitoring, and in some cases also provides alarm or control outputs for added functionality.

Product reviews
It offers professional-grade functionality
5
Sage
Avatar
1/4/2026 11:21 PM
Clear 4-digit display and stable readings. Works reliably with DC sensors.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Hall Effect Current Sensor 50A/100A/300A/800A/1200A to 1500A

ATO-CUS-ACDC1500
$93.23
Hall effect current sensors are AC/DC universal current sensors, with split-core structure, 5us fast response time, 1.0%FS accuracy, 0-5V/ 0-±5VDC output signal, ±15V power supply, fixed installation. Open loop current sensors are widely used for AC and DC current monitoring, system signal acquisition and feedback control.