Digital Load Cell, RS232/RS485, 3kg/5kg/25kg/40kg to 350kg

$110.99
Inexpensive digital load cell for sale, available in several measurement ranges 0-350kg. The load cell can use two output methods to choose from RS485, RS232, with accurate ±0.05%, 150% F.S safety overload. Digital temperature compensation, intelligent creep compensation to maintain stability. Mainly used in intelligent shelves, intelligent gravity cabinets, garbage collection and other occasions.
SKU: ATO-LC-GPB
*
*
Free Shipping
Delivery date: 15-30 days

After purchasing one ATO load cell, you can buy a special digital display controller to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Digital load cell weight sensor are available in multiple measurement ranges: 0-350kg. They support two output options: RS485 and RS232, with a high accuracy of ±0.05% and a 150% F.S safety overload.

Specification

ModelATO-GPB100D/ATO-GPB144D
Measuring Range3/5/10/20/30/40/50 (kg) (ATO-GPB100D)
60/100/200/350 (kg) (ATO-GPB144D)
Resolution<5kg: 0.1g, ≤50kg: 1g, 60-100kg: 2g, 150-200kg: 5g, 350kg: 10g
Identification RateDefault 1 (adjustable based on user application)
Comprehensive Error0.005% F.S
Zero Temperature Drift0.002% F.S/°C
Span Temperature Drift0.002% F.S/°C
Creep0.018% F.S/30min
Output SignalRS485 or RS232
BaudRS485:115200, RS232:19200
A/D Sample Rate1200 times/second
A/D Resolution300000
Weight Output SpeedRS485: 3ms, RS232: 20ms
Operating TemperatureRS485: -20~+70°C, RS232: -10~+70°C
Power Supply Voltage5~12VDC
Safe Load150%
Ultimate Load200%
Cable TypeFour-core shielded cable
Cable Lengthφ5mm × 1.5m
Protection LevelIP65
Communication ProtocolRS485: MODBUS RTU & factory custom protocol, RS232: factory custom protocol only


Feature

Digital load cell feature

  • Durable Construction: Made of aluminum alloy with anodized surface treatment for enhanced corrosion resistance and longevity.
  • Integrated Digital Module: Built-in digital signal processing unit provides high accuracy and stable performance.
  • Multiple Communication Options: Digital load sensor supports RS485 and RS232 digital signal output, making it compatible with various industrial systems.
  • Large Weighing Platform: Supports a maximum sample plate size of 400 × 400mm, suitable for different applications.
  • Pre-Calibrated for Convenience: Factory calibration eliminates the need for on-site adjustments, simplifying installation.
  • Customizable Weight Acceleration: Digital load cell weight sensor allows users to modify weight acceleration settings to suit different environments.
  • Adaptive Resolution: Automatically adjusts resolution based on the measured weight, eliminating the need for manual recalibration.
  • Simple Command Control: RS485 load cell requires only one zeroing command and one weight retrieval command for efficient operation.
  • Wide Application Range: Suitable for smart storage shelves, intelligent weight cabinets, and waste recycling stations.

Dimension (unit: mm)

3-50kg size:

Digital load cell dimension

60-350kg size:

Digital load cell size

Wiring Definition

RS232RS485ColorDescription
+V+VRed5~12VDC
GNDGNDBlack0V
RDAGreenConnect to external device TXD or A
TDBWhiteConnect to external device RXD or B


Application

Digital load cell application

Tips: How does an RS485 digital load cell differ from an RS232 load cell?

RS485 and RS232 are both serial communication protocols used in digital load cells, but they differ in performance, distance, and application:

RS232 (Short-Distance Communication):

  • Supports point-to-point communication (one load cell to one device).
  • Transmission distance is limited to around 15 meters.
  • Commonly used for single-device connections, such as computers or display units.

RS485 (Long-Distance & Multi-Device Communication):

  • Supports multi-drop networking (one load cell can communicate with multiple devices).
  • Transmission distance extends up to 1200 meters, making it ideal for large-scale industrial applications.
  • More resistant to electrical interference, ensuring stable data transmission in noisy environments.
Product reviews
Measuring table
5
Tarns
Avatar
4/29/2025 8:29 PM
How long does the table need to be to be able to measure with just one load cell?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, it is difficult to ensure accuracy when placing a load cell under the table, which can cause off-center loading and produce errors.
RS232 port
5
Indre
Avatar
1/26/2026 6:40 PM
I'm looking for a load cell that can be directly connected to an AIO stainless steel terminal with an RS232 port. No indicator is needed between the load cell and the terminal. Would the ATO-LC-GPB meet my needs?
Was this review helpful? Yes No (0/0)
ATO Responded
This load cell can be directly connected to an AIO stainless steel terminal with an RS232 port. No indicator is needed between the load cell and the terminal, but it's made of aluminum alloy. Otherwise, it meets your requirements. Is it suitable?
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

After purchasing one ATO load cell, you can buy a special digital display controller to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Digital load cell weight sensor are available in multiple measurement ranges: 0-350kg. They support two output options: RS485 and RS232, with a high accuracy of ±0.05% and a 150% F.S safety overload.

Specification

ModelATO-GPB100D/ATO-GPB144D
Measuring Range3/5/10/20/30/40/50 (kg) (ATO-GPB100D)
60/100/200/350 (kg) (ATO-GPB144D)
Resolution<5kg: 0.1g, ≤50kg: 1g, 60-100kg: 2g, 150-200kg: 5g, 350kg: 10g
Identification RateDefault 1 (adjustable based on user application)
Comprehensive Error0.005% F.S
Zero Temperature Drift0.002% F.S/°C
Span Temperature Drift0.002% F.S/°C
Creep0.018% F.S/30min
Output SignalRS485 or RS232
BaudRS485:115200, RS232:19200
A/D Sample Rate1200 times/second
A/D Resolution300000
Weight Output SpeedRS485: 3ms, RS232: 20ms
Operating TemperatureRS485: -20~+70°C, RS232: -10~+70°C
Power Supply Voltage5~12VDC
Safe Load150%
Ultimate Load200%
Cable TypeFour-core shielded cable
Cable Lengthφ5mm × 1.5m
Protection LevelIP65
Communication ProtocolRS485: MODBUS RTU & factory custom protocol, RS232: factory custom protocol only


Feature

Digital load cell feature

  • Durable Construction: Made of aluminum alloy with anodized surface treatment for enhanced corrosion resistance and longevity.
  • Integrated Digital Module: Built-in digital signal processing unit provides high accuracy and stable performance.
  • Multiple Communication Options: Digital load sensor supports RS485 and RS232 digital signal output, making it compatible with various industrial systems.
  • Large Weighing Platform: Supports a maximum sample plate size of 400 × 400mm, suitable for different applications.
  • Pre-Calibrated for Convenience: Factory calibration eliminates the need for on-site adjustments, simplifying installation.
  • Customizable Weight Acceleration: Digital load cell weight sensor allows users to modify weight acceleration settings to suit different environments.
  • Adaptive Resolution: Automatically adjusts resolution based on the measured weight, eliminating the need for manual recalibration.
  • Simple Command Control: RS485 load cell requires only one zeroing command and one weight retrieval command for efficient operation.
  • Wide Application Range: Suitable for smart storage shelves, intelligent weight cabinets, and waste recycling stations.

Dimension (unit: mm)

3-50kg size:

Digital load cell dimension

60-350kg size:

Digital load cell size

Wiring Definition

RS232RS485ColorDescription
+V+VRed5~12VDC
GNDGNDBlack0V
RDAGreenConnect to external device TXD or A
TDBWhiteConnect to external device RXD or B


Application

Digital load cell application

Tips: How does an RS485 digital load cell differ from an RS232 load cell?

RS485 and RS232 are both serial communication protocols used in digital load cells, but they differ in performance, distance, and application:

RS232 (Short-Distance Communication):

  • Supports point-to-point communication (one load cell to one device).
  • Transmission distance is limited to around 15 meters.
  • Commonly used for single-device connections, such as computers or display units.

RS485 (Long-Distance & Multi-Device Communication):

  • Supports multi-drop networking (one load cell can communicate with multiple devices).
  • Transmission distance extends up to 1200 meters, making it ideal for large-scale industrial applications.
  • More resistant to electrical interference, ensuring stable data transmission in noisy environments.
Product reviews
Measuring table
5
Tarns
Avatar
4/29/2025 8:29 PM
How long does the table need to be to be able to measure with just one load cell?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, it is difficult to ensure accuracy when placing a load cell under the table, which can cause off-center loading and produce errors.
RS232 port
5
Indre
Avatar
1/26/2026 6:40 PM
I'm looking for a load cell that can be directly connected to an AIO stainless steel terminal with an RS232 port. No indicator is needed between the load cell and the terminal. Would the ATO-LC-GPB meet my needs?
Was this review helpful? Yes No (0/0)
ATO Responded
This load cell can be directly connected to an AIO stainless steel terminal with an RS232 port. No indicator is needed between the load cell and the terminal, but it's made of aluminum alloy. Otherwise, it meets your requirements. Is it suitable?
Only registered users can write reviews