Features
- Multi-specification test function, The test voltage or current automatic level control of ALC function.
- Output impedance of 4 different signal sources: 30Ω, 50Ω, 100Ω, 10/CC.
- Internal 0V, 1.5V and 2V DC bias voltage, optional ± 5V (± 100mA) and 1A internal DC bias source.
- Built-in comparator, 10 bins and bin counters. 10 point list scanning function.
Specification
| Model | ATO-LCRM-2828 | ATO-LCRM-2819 |
| Test Frequency | 20Hz~1MHz, 0.01Hz resolution | 20Hz~500kHz, 0.01Hz resolution |
| Test Specifications | |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR | |
| Basic Test Accuracy | 0.05% | |
| Equivalent Circuit | Series, parallel | |
| Mathematical Function | Absolute value deviation, percentage deviation | |
| Range Mode | Auto, Hold, manual | |
| Trigger Mode | Internal, Manual, External, Bus | |
| Measurement Speed (≥1kHz) | Fast: 75 time/second, Med: 12 time/second, Slow: 3 time/second | |
| Averaging Rate | 1—255 | |
| Delay Time | time 0—60s, n 1 ms step by step | |
| Correction Function | Open, short, load | |
| List Sweep | 10 points | |
| Display Mode | Direct, Δ, Δ%, V/I (V/I monitor) | |
| Display | 800×480 RGB7inch 16:9 TFT LCD display | |
| Power Requirements | 110V~240V | |
| Test signal | ||
| Output Impedance | 30Ω, 50Ω, 100Ω, 10/CC selectable | |
| Test Level | Normal: 5mV-2V Accuracy: 10%, with step of 1 mV Constant level: 10mV-1V Accuracy: 5%, with step of 1 mV | |
| DC Bias Source | interior: 0V, 1.5V, 2V, Accuracy 1%| option: ±5V (±100mA) Dc bias source option 1A: 0-1A DC bias current source option. | |
| Display Range | |Z|, R, X: 0.01MΩ—99.9999 MΩ DCR: 0.001MΩ—99.9999MΩ |Y|, G, B: 0.00001µS—99.9999S C: 0.00001pF—9.9999F L: 0.00001µH—9999.99H D: 0.00001—9.9999 Q: 0.00001—9999.9 θ (DEG): -179.999º—179.999º θ (RAD): -3.14159—3.14159 | |
| Comparator Function | 10 bins: 9 pass bin, 1 fail bin, AUX bin | |
| Multiparameter | Four parameters can be chosen optionally measure and display at the same time | |
| Curve Scanning Function | A variety of test conditions, the piece to be measured for graph scanning separation | |
| Memory | Internal storage, USB extended storage | |
| Interface | Standard: RS232C, HANDLER, USB HOST, USB DEVICE, headphone jack, solid interface Optional: GPIB, LAN | |
| Size | 375mm (W)*135mm (H)*350mm (L) | |
| Certification | CE | |
| Standard Accessories | 26011B 4 terminal Kelvin test clip leads 26005B 4 terminal test fixture 26010 gilded shorting plate | |
| Optional Accessories | 26009B SMD test fixture 26008A SMD Test box 26010 gilded shorting plate RS232 Communication software customization | |
Panel Details

Dimension Drawing

Tips: LCR meter measurement steps.
- Set the test frequency.
- Test voltage or current level.
- Select test specifications, such as C, L, X, B, R, G, D, | Z |, | Y |, etc.
- Instrument calibration, mainly for open and short calibration, more precise LCR meter also needs to perform load calibration.
- Select test fixture.
- Fixture compensation
- Put the DUT on the fixture to start test.
Product reviews
Digital LCD meter measurement results are accurate
Cdesperado
8/12/2021 8:46 PM
This inexpensive LCR meter seems to work well. I checked its reading against a LCR meter and its within its rated spec. It is perfect for everyday testing and measurement result is very accurate.
Was this review helpful? (0/0)
Only registered users can write reviews