Differential Pressure Transducer, Output 4-20mA HART

$686.67
Differential pressure transducer provides 0.1% FS accuracy, measuring ranges up to 3 MPa, and optional 4–20mA or 4–20mA HART output. Designed for differential pressure measurement of air, water and oil with medium temperatures from -40°C to 60°C.
SKU: ATO-PRES-2051
*
*
*
*
*
*
*
*
Free Shipping
Delivery date: 8-12 days

Differential pressure transducer for air/water/oil pressure measurement has optional output signal 4-20mA or 4-20mA HART.


Applications

Pressure transducer is widely used in process control, chemical, petroleum and metallurgical industry and other fields.


Features

  • Model: ATO-PRES-2051
  • Measuring Range: 0~3MPa (0~30bar/0~435 psi)
  • Range Ratio: 10:1 (minimum), 100:1 (maximum)
  • Output Signal: 4-20mA, 4-20mA HART
  • Accuracy: ±0.1%FS
  • Power Supply: DC 24V
  • Connection: The connecting thread on the pressure tap is 1/2 NPT. The thread of the output cable connection hole is M20*1.5 mm.
  • Protection Class: IP65
  • Measuring Medium: Air, water, oil
  • Pressure Type: Gauge pressure (standard), contact us for absolute pressure, sealed pressure type (note that the measuring range for these two types must ≤1MPa)

Mounting Diagram

Unit: mm.

Differential pressure transducer mounting diagram


Wiring Diagram

Differential pressure transducer wiring diagram


Tips: Operating steps of start and stop a differential pressure transducer

There are at least five valves connecting with the differential pressure transducer, among, two sampling valves are used for sampling and cutting off the process media, two blow-down valves are used to flush the connecting pipe or remove condensate or gas from the connecting pipe. The connecting pipes are connected with the differential pressure transducer through three-valve group or five-valve group, and the starting and stopping of differential pressure transducer are mostly operated on the three-valve group.

  1. Stop Method of Differential Pressure Transducer
    When closing the differential pressure transducer, the steps for closing the three-valve group are as follows: close the negative pressure valve first, then open the balanced valve, and finally close the positive pressure valve. If the differential pressure transducer is out of operation for a long time, both positive and negative pressure valves of primary valve and three-valve group should be closed, the balanced valve should be opened to ensure equal pressure on both sides of the transducer's measuring room, in a balanced state.
  2. Start Method of Differential Pressure Transducer
    When starting the differential pressure transducer, the steps for opening the three-valve group are as follows: open the positive pressure valve firstly, then close the balanced valve, and finally open the negative pressure valve.
    When starting or stopping the differential pressure transducer for steam flow measurement, the differential pressure transducer with isolator, and the liquid level differential pressure transducer with a balanced container, the positive pressure valve/negative pressure valve/balanced valve cannot be opened at the same time when operating the three-valve group. Because even if it is opened in a short time, the condensate water in the balanced container and the isolation fluid in the isolator may run off, resulting in the incorrect display of meter, and even the differential pressure transducer cannot be put into operation in serious cases. When necessary, the drain valve and exhaust valve on the measurement room of differential pressure transducer shall be used to remove the air or condensate water.

Measuring range conversion table:

UnitkPaMPabarpsi
Measuring range0~50~0.0050~0.050~0.7
0~100~0.010~0.10~1.5
0~200~0.020~0.20~3
0~500~0.050~0.50~7
0~1000~0.10~10~14
-100~0-0.1~0-1~0-14~0
-100~100-0.1~0.1-1~1-14~14
0~6000~0.60~60~87
0~10000~10~100~145
0~16000~1.60~160~232
0~25000~2.50~250~362
0~60000~60~600~870
0~100000~100~1000~1450
0~200000~200~2000~2900
0~300000~300~3000~4351
0~400000~400~4000~5801
0~500000~500~5000~7252
0~600000~600~6000~8702
0~1000000~1000~10000~14503



In this video, ATO will show you top ten most used sensors (sensing technologies).

Product reviews
High quality differential pressure transducer
5
Minnoesta
Avatar
7/16/2021 12:57 AM
I bought a differential pressure transducer some time ago. ATO's service is very good. I decided to order another 4-20mA HART differential pressure sensor.
Was this review helpful? Yes No (0/0)
Explosion-proof Differential Pressure Sensor
5
Quimby
Avatar
10/29/2025 12:37 AM
Hello, do you have explosion-proof differential pressure sensors suitable for flangeless environments?
Was this review helpful? Yes No (0/0)
ATO Responded
Okay, what is the pressure range of the differential pressure sensor you are looking for? Also, what are the connection threads for the pressure sensor? This differential pressure sensor has an output of 4-20mA, SKU: ATO-PRES-2051. We can customize an explosion-proof type Ex d IIC T6 Gb.
Filter monitoring
5
Tokney
Avatar
3/27/2026 2:04 AM
I need an explosion-proof or intrinsically safe differential pressure sensor (for filter monitoring) for airflow measurement (if available), compatible with 4–20 mA or Modbus output sensors, and any available certifications (ATEX, IECEx, or equivalent).
Was this review helpful? Yes No (0/0)
ATO Responded
1. For differential pressure measurement, you can refer to our ATO-PRES-2051 differential pressure sensor, but it is not explosion-proof.
2. For temperature and humidity measurement, you can refer to our explosion-proof temperature and humidity sensor ATO-TAHS-EP. See details at: https://www.ato.com/explosion-proof-temperature-and-humidity-sensor
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Differential pressure transducer for air/water/oil pressure measurement has optional output signal 4-20mA or 4-20mA HART.


Applications

Pressure transducer is widely used in process control, chemical, petroleum and metallurgical industry and other fields.


Features

  • Model: ATO-PRES-2051
  • Measuring Range: 0~3MPa (0~30bar/0~435 psi)
  • Range Ratio: 10:1 (minimum), 100:1 (maximum)
  • Output Signal: 4-20mA, 4-20mA HART
  • Accuracy: ±0.1%FS
  • Power Supply: DC 24V
  • Connection: The connecting thread on the pressure tap is 1/2 NPT. The thread of the output cable connection hole is M20*1.5 mm.
  • Protection Class: IP65
  • Measuring Medium: Air, water, oil
  • Pressure Type: Gauge pressure (standard), contact us for absolute pressure, sealed pressure type (note that the measuring range for these two types must ≤1MPa)

Mounting Diagram

Unit: mm.

Differential pressure transducer mounting diagram


Wiring Diagram

Differential pressure transducer wiring diagram


Tips: Operating steps of start and stop a differential pressure transducer

There are at least five valves connecting with the differential pressure transducer, among, two sampling valves are used for sampling and cutting off the process media, two blow-down valves are used to flush the connecting pipe or remove condensate or gas from the connecting pipe. The connecting pipes are connected with the differential pressure transducer through three-valve group or five-valve group, and the starting and stopping of differential pressure transducer are mostly operated on the three-valve group.

  1. Stop Method of Differential Pressure Transducer
    When closing the differential pressure transducer, the steps for closing the three-valve group are as follows: close the negative pressure valve first, then open the balanced valve, and finally close the positive pressure valve. If the differential pressure transducer is out of operation for a long time, both positive and negative pressure valves of primary valve and three-valve group should be closed, the balanced valve should be opened to ensure equal pressure on both sides of the transducer's measuring room, in a balanced state.
  2. Start Method of Differential Pressure Transducer
    When starting the differential pressure transducer, the steps for opening the three-valve group are as follows: open the positive pressure valve firstly, then close the balanced valve, and finally open the negative pressure valve.
    When starting or stopping the differential pressure transducer for steam flow measurement, the differential pressure transducer with isolator, and the liquid level differential pressure transducer with a balanced container, the positive pressure valve/negative pressure valve/balanced valve cannot be opened at the same time when operating the three-valve group. Because even if it is opened in a short time, the condensate water in the balanced container and the isolation fluid in the isolator may run off, resulting in the incorrect display of meter, and even the differential pressure transducer cannot be put into operation in serious cases. When necessary, the drain valve and exhaust valve on the measurement room of differential pressure transducer shall be used to remove the air or condensate water.
Product reviews
High quality differential pressure transducer
5
Minnoesta
Avatar
7/16/2021 12:57 AM
I bought a differential pressure transducer some time ago. ATO's service is very good. I decided to order another 4-20mA HART differential pressure sensor.
Was this review helpful? Yes No (0/0)
Explosion-proof Differential Pressure Sensor
5
Quimby
Avatar
10/29/2025 12:37 AM
Hello, do you have explosion-proof differential pressure sensors suitable for flangeless environments?
Was this review helpful? Yes No (0/0)
ATO Responded
Okay, what is the pressure range of the differential pressure sensor you are looking for? Also, what are the connection threads for the pressure sensor? This differential pressure sensor has an output of 4-20mA, SKU: ATO-PRES-2051. We can customize an explosion-proof type Ex d IIC T6 Gb.
Filter monitoring
5
Tokney
Avatar
3/27/2026 2:04 AM
I need an explosion-proof or intrinsically safe differential pressure sensor (for filter monitoring) for airflow measurement (if available), compatible with 4–20 mA or Modbus output sensors, and any available certifications (ATEX, IECEx, or equivalent).
Was this review helpful? Yes No (0/0)
ATO Responded
1. For differential pressure measurement, you can refer to our ATO-PRES-2051 differential pressure sensor, but it is not explosion-proof.
2. For temperature and humidity measurement, you can refer to our explosion-proof temperature and humidity sensor ATO-TAHS-EP. See details at: https://www.ato.com/explosion-proof-temperature-and-humidity-sensor
Only registered users can write reviews
Customers who bought this item also bought

Submersible Level Sensor for Water/Oil/Fuel Tank, 0-200M

ATO-LEVS-S200M
$173.28
Submersible level sensor adopts 304 stainless steel housing and waterproof cable, can be put in water/oil/fuel tank or reservoir directly for liquid level measurement. The measuring range can be 0-1m/0-3m/0-5m/0-10m ~ 0-200m. Liquid level sensor has optional accuracy 0.5%FS or 0.3%FS, output signal 4-20mA/0-5V/RS485, power supply DC 24V/12V. The cable type and connection type are also customizable.

High Temperature Explosion Proof Pressure Sensor, -20℃~350℃

ATO-PRES-PT85
$266.15
Explosion-proof pressure sensor measures up to 60 MPa at temperatures from -20°C to 350°C, with 4–20mA, HART or RS485 output options. Stainless steel construction and cooling fins make it suitable for high-temperature steam and fuel oil pressure measurement.