DTU Data Transfer Unit, Modbus RS485

$199.89
Data transfer unit (DTU) is a remote data control product. Wireless acquisition function supports Modbus RTU protocol, communication interface is RS-485, transmission distance is 8km. DTU has switch value follow and control acquisition functions. It supports 2-channel isolation switch inputs and 2-channel relay outputs.
SKU: ATO-DTFU-E8
*
Free Shipping
Delivery date: 6-12 days

Features

  • Supports 2-channel switch value input and 2-channel relay output. Modbus RTU protocol data processing.
  • Use 433MHz frequency for wireless data remote transmission.
  • 4 working modes: wireless control acquisition mode, wireless follow-up transmission mode, wireless follow-up reception mode, and configuration mode. Select by DIP switch.
  • RESET touch reset button. Press and hold for 5s in wireless control acquisition mode, the Modbus address is restored to the default address 01.
  • Built-in efficient watchdog with high reliability and stability.
  • Power supply has good functions of preventing over-current, over-voltage, and reverse connection.

Note: Before purchasing, please confirm that the frequency band used by the device complies with local laws and regulations.

Specification

ModelATO-E820-DTU (2I2-433L)ATO-E830-DTU (2R2-433L)
Acquisition Range4-20mASwitch Value/Digital Value
Acquisition Channels2-channel2-channel
Transmission Distance8km8km
RF Specifications
Standard Frequency433MHz426MHz
TX Power1W1W
Hardware Specifications
Operation Temperature-20℃~+70℃-40℃~+70℃
Storage Temperature-40℃~+85℃-40℃~+85℃
Operation Humidity5%~95%
Storage Humidity1%~95%
Operation Voltage8V~28V
Current Collecting Range0mA~20mA-
Current Output Range0mA~20mA-
Relay Output-5A 30VDC/5A 250VAC
Accuracy0.2%
Data InterfaceRS485: 9600bps
Size (H*W*D)120mm*105mm*25mm
CertificationCE, CCC
Soft Specifications
Operation ModeFollowing TX, Following RX, Controlling/Collecting, Configuration
Configuration CommandModbus RTU
PDFDownload AttachmentsE820-DTU User Manual

Dimension and Interface Description (Unit: mm)

Installation Dimension of Data Transfer Unit Model E820

Installation Dimension of Data Transfer Unit Model E830

Interface Dimension of Dimension Drawing of Data Transfer Unit Model 2I2/2R2

Tips: What is data transfer unit (DTU) ?

Data transfer unit (DTU) is a wireless terminal device, it is used to convert serial data into IP data or convert IP data into serial data. It is transmitted through wireless communication network. DTU is widely used in industry, meteorology, hydrology and water conservancy, geology and other industries.

Data transfer unit hardware components mainly include CPU control module, wireless communication module and power module. Its advantages include rapid and flexible networking, short construction period, low cost, wide network coverage, good security and confidentiality performance, link support always online and low user cost, etc.

How to Realize VFD Remote Control/DTU Wireless Control?

The video shows how to use ATO DTU to remotely control VFD. The transmission distance of ATO DTU can reach 8 kilometers.

Industrial Wireless Data Transmission Control Test/Data Transmission Unit

The video introduces that ATO DTU can realize remote data transmission function, but the output signal is analog signal or digital signal. Therefore, it is widely used in the control of industrial and agricultural equipment and the collection of field data.

IoT Data Transmission Unit Configuration and Wireless Data Acquisition Test

The video shows the configuration of ATO DTU. ATO-DTU can save a lot of traditional cables, and wireless data transmission can be easily configured in just a few steps.

Analog-to-digital Converter/Field Data Collector Test

The video shows that the 4-20mA analog quantity is converted into a digital signal through the data collector and displayed on the PC.

Product reviews
Affordable DTU data transfer unit
5
Loblaw
Avatar
3/16/2021 3:14 AM
If I want to purchase multiple Modbus RS485DTU data transfer units, do you have a discount?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide discounts for customers who purchase multiple Modbus RS485DTU data transfer units.
It fits my requirements really well
5
Chandler
Avatar
10/21/2025 9:27 PM
Works great for my remote monitoring setup. The setup was super easy, and it’s been transferring data flawlessly even from far away. Reliable, stable, and saves me a lot of hassle. It's exactly what I needed for my remote monitoring system.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Features

  • Supports 2-channel switch value input and 2-channel relay output. Modbus RTU protocol data processing.
  • Use 433MHz frequency for wireless data remote transmission.
  • 4 working modes: wireless control acquisition mode, wireless follow-up transmission mode, wireless follow-up reception mode, and configuration mode. Select by DIP switch.
  • RESET touch reset button. Press and hold for 5s in wireless control acquisition mode, the Modbus address is restored to the default address 01.
  • Built-in efficient watchdog with high reliability and stability.
  • Power supply has good functions of preventing over-current, over-voltage, and reverse connection.

Note: Before purchasing, please confirm that the frequency band used by the device complies with local laws and regulations.

Specification

ModelATO-E820-DTU (2I2-433L)ATO-E830-DTU (2R2-433L)
Acquisition Range4-20mASwitch Value/Digital Value
Acquisition Channels2-channel2-channel
Transmission Distance8km8km
RF Specifications
Standard Frequency433MHz426MHz
TX Power1W1W
Hardware Specifications
Operation Temperature-20℃~+70℃-40℃~+70℃
Storage Temperature-40℃~+85℃-40℃~+85℃
Operation Humidity5%~95%
Storage Humidity1%~95%
Operation Voltage8V~28V
Current Collecting Range0mA~20mA-
Current Output Range0mA~20mA-
Relay Output-5A 30VDC/5A 250VAC
Accuracy0.2%
Data InterfaceRS485: 9600bps
Size (H*W*D)120mm*105mm*25mm
CertificationCE, CCC
Soft Specifications
Operation ModeFollowing TX, Following RX, Controlling/Collecting, Configuration
Configuration CommandModbus RTU
PDFDownload AttachmentsE820-DTU User Manual

Dimension and Interface Description (Unit: mm)

Installation Dimension of Data Transfer Unit Model E820

Installation Dimension of Data Transfer Unit Model E830

Interface Dimension of Dimension Drawing of Data Transfer Unit Model 2I2/2R2

Tips: What is data transfer unit (DTU) ?

Data transfer unit (DTU) is a wireless terminal device, it is used to convert serial data into IP data or convert IP data into serial data. It is transmitted through wireless communication network. DTU is widely used in industry, meteorology, hydrology and water conservancy, geology and other industries.

Data transfer unit hardware components mainly include CPU control module, wireless communication module and power module. Its advantages include rapid and flexible networking, short construction period, low cost, wide network coverage, good security and confidentiality performance, link support always online and low user cost, etc.

Product reviews
Affordable DTU data transfer unit
5
Loblaw
Avatar
3/16/2021 3:14 AM
If I want to purchase multiple Modbus RS485DTU data transfer units, do you have a discount?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide discounts for customers who purchase multiple Modbus RS485DTU data transfer units.
It fits my requirements really well
5
Chandler
Avatar
10/21/2025 9:27 PM
Works great for my remote monitoring setup. The setup was super easy, and it’s been transferring data flawlessly even from far away. Reliable, stable, and saves me a lot of hassle. It's exactly what I needed for my remote monitoring system.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews