Current Transformer Tester, CT PT Analyzer, 110V/220V

$15,649.23
CT PT analyzer for sale, low price, input voltage 110V or 220V, frequency 50Hz/60Hz, current transformer tester is used for the excitation characteristics, ratio, polarity, secondary winding resistance, ratio difference and angle difference of CT, PT electromagnetic units.
SKU: ATO-CT-HM404
*
Free Shipping
Delivery date: 10-20 days

Current transformer tester set for knee point test, CT PT analyzer input voltage 110V or 220V is available, 50Hz/60Hz, functional test stability and high efficiency.

Specification:

ModelATO-CT-HM404
Input VoltageAC220V, 50Hz/AC110V, 60Hz
UsageClass P/TP CT & VT
Power Output500VA
Maximum Knee Voltage Measurement45 kV
Voltage Output0.1~180V (AC)
Current Output0.001~5A(RMS)
Current MeasurementRange0~10A (Automatically change range in 0.1/0.4/2/10A)
Error<±0.1%+0.01%FS
Voltage MeasurementRange0~200V (Automatically change range in 1V/10V/70V/200V)
Error<±0.1%+0.01%FS
Turns Ratio MeasurementRange1~50005000~35000
Error<0.05%<0.1%
Phase MeasurementRange±2min
Resolution0.01min
Winding Resistance MeasurementRange0~8kΩ (Automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error<0.2%RDG+0.02%FS
Maximum resolution0.1mΩ
Temperature Measurement-50~100 Celsius degree
CT Secondary BurdenRange0~160ohm (Automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error<0.2%RDG+0.02%FS
Maximum resolution0.001ohm
PT Secondary BurdenRange0~80kohm (Automatically change range in 800ohm/8kohm/80kohm)
Error<0.2%RDG+0.02%FS
Maximum Resolution0.1ohm
PT Ratio MeasurementRange1~1000010000~35000
Error<0.1%<0.2%
PT Ratio Error MeasurementTypical Error<0.05%
Maximum Error<0.1%
PT Phase Angle Measurementmaximum Error<3min
Memory Capacity>1000 Groups Test Results
Working ConditionTemperature: -10℃~50℃Moist: ≤90%
Dimension485*356*183mm
Weight15kg

Features and Advantages

1. Simple test, full-featured, meet CT and PT test requirements.
2. High degree of automation, the experimental report of the current transformer tester, can complete the analysis of the test source data file and the production word report through the PC machine software, automatically give the knee voltage, current, 10%, 5% error curve, accuracy limit coefficient (ALF), instrument security factor (FS), quadratic time constant (Ts), remanence coefficient (Kr), saturation and unsaturated inductance, CT, CP parameters.
3. The current transformer tester can store 2000 sets of test data, which can be stored in the PC with a U disk.
4. Stable performance and high test efficiency. Lightweight and easy to carry.
Test for current transformerWhat is the Current Transformer Analyzer?

The current transformer analyzer is a multifunctional field test instrument specially designed for testing transformers: volt-ampere characteristics, ratio, polarity, error curve, calculation of inflection point and secondary side circuit inspection. In the experiment, only the test voltage and current value need to be set, the device can automatically boost/upflow, and the volt-ampere characteristic curve or ratio, polarity and other experimental results of the transformer can be quickly displayed to support data saving and field printing. It not only saves the tedious labor of manual voltage regulation, manual recording, curve drawing, etc., but also uploads test data to the computer for editing, saving or printing through the USB interface. The operation is simple and convenient, and the work efficiency is improved. It is a high-tech product with high cost performance.

Product reviews
This 110V220V current transformer is exactly what I need
5
Simonc
Avatar
11/22/2021 8:12 PM
This 110V/220V current transformer is exactly what I need. I need to verify the parameters of the CT nameplate. It can accurately verify the parameters. In addition to this function, there are other powerful functions. It is strongly recommended that you buy it.
Was this review helpful? Yes No (0/0)
Physical parameters of current transformers
5
Sampson
Avatar
1/17/2022 11:35 PM
What are the units on the accuracy of your current transformer? Amps? % of rated amps?
Was this review helpful? Yes No (0/0)
ATO Responded
%. The CT has accuracy levels of classes 1, classes 0.5 and classes 0.2. For example: classes 0.5, means that the measurement error is within ±0.5% of the standard test data.
Adequate Performance of the Current Transformer Tester
5
Cecil
Avatar
10/4/2023 11:59 PM
The Current Transformer Tester and CT PT Analyzer with 110V/220V options are decent pieces of equipment. They perform adequately for their intended purpose. While they may not stand out as exceptional, they get the job done when it comes to testing and analyzing current transformers and potential transformers. The dual voltage options are a nice touch for added flexibility. Overall, these testers are functional tools for professionals who need basic testing capabilities.
Was this review helpful? Yes No (0/0)
Dual Functionality
5
Draven
Avatar
11/23/2023 6:34 PM
The CT PT Analyzer offers dual functionality, allowing users to test both current transformers and potential transformers.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Current transformer tester set for knee point test, CT PT analyzer input voltage 110V or 220V is available, 50Hz/60Hz, functional test stability and high efficiency.

Specification:

ModelATO-CT-HM404
Input VoltageAC220V, 50Hz/AC110V, 60Hz
UsageClass P/TP CT & VT
Power Output500VA
Maximum Knee Voltage Measurement45 kV
Voltage Output0.1~180V (AC)
Current Output0.001~5A(RMS)
Current MeasurementRange0~10A (Automatically change range in 0.1/0.4/2/10A)
Error<±0.1%+0.01%FS
Voltage MeasurementRange0~200V (Automatically change range in 1V/10V/70V/200V)
Error<±0.1%+0.01%FS
Turns Ratio MeasurementRange1~50005000~35000
Error<0.05%<0.1%
Phase MeasurementRange±2min
Resolution0.01min
Winding Resistance MeasurementRange0~8kΩ (Automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error<0.2%RDG+0.02%FS
Maximum resolution0.1mΩ
Temperature Measurement-50~100 Celsius degree
CT Secondary BurdenRange0~160ohm (Automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error<0.2%RDG+0.02%FS
Maximum resolution0.001ohm
PT Secondary BurdenRange0~80kohm (Automatically change range in 800ohm/8kohm/80kohm)
Error<0.2%RDG+0.02%FS
Maximum Resolution0.1ohm
PT Ratio MeasurementRange1~1000010000~35000
Error<0.1%<0.2%
PT Ratio Error MeasurementTypical Error<0.05%
Maximum Error<0.1%
PT Phase Angle Measurementmaximum Error<3min
Memory Capacity>1000 Groups Test Results
Working ConditionTemperature: -10℃~50℃Moist: ≤90%
Dimension485*356*183mm
Weight15kg

Features and Advantages

1. Simple test, full-featured, meet CT and PT test requirements.
2. High degree of automation, the experimental report of the current transformer tester, can complete the analysis of the test source data file and the production word report through the PC machine software, automatically give the knee voltage, current, 10%, 5% error curve, accuracy limit coefficient (ALF), instrument security factor (FS), quadratic time constant (Ts), remanence coefficient (Kr), saturation and unsaturated inductance, CT, CP parameters.
3. The current transformer tester can store 2000 sets of test data, which can be stored in the PC with a U disk.
4. Stable performance and high test efficiency. Lightweight and easy to carry.
Test for current transformerWhat is the Current Transformer Analyzer?

The current transformer analyzer is a multifunctional field test instrument specially designed for testing transformers: volt-ampere characteristics, ratio, polarity, error curve, calculation of inflection point and secondary side circuit inspection. In the experiment, only the test voltage and current value need to be set, the device can automatically boost/upflow, and the volt-ampere characteristic curve or ratio, polarity and other experimental results of the transformer can be quickly displayed to support data saving and field printing. It not only saves the tedious labor of manual voltage regulation, manual recording, curve drawing, etc., but also uploads test data to the computer for editing, saving or printing through the USB interface. The operation is simple and convenient, and the work efficiency is improved. It is a high-tech product with high cost performance.

Product reviews
This 110V220V current transformer is exactly what I need
5
Simonc
Avatar
11/22/2021 8:12 PM
This 110V/220V current transformer is exactly what I need. I need to verify the parameters of the CT nameplate. It can accurately verify the parameters. In addition to this function, there are other powerful functions. It is strongly recommended that you buy it.
Was this review helpful? Yes No (0/0)
Physical parameters of current transformers
5
Sampson
Avatar
1/17/2022 11:35 PM
What are the units on the accuracy of your current transformer? Amps? % of rated amps?
Was this review helpful? Yes No (0/0)
ATO Responded
%. The CT has accuracy levels of classes 1, classes 0.5 and classes 0.2. For example: classes 0.5, means that the measurement error is within ±0.5% of the standard test data.
Adequate Performance of the Current Transformer Tester
5
Cecil
Avatar
10/4/2023 11:59 PM
The Current Transformer Tester and CT PT Analyzer with 110V/220V options are decent pieces of equipment. They perform adequately for their intended purpose. While they may not stand out as exceptional, they get the job done when it comes to testing and analyzing current transformers and potential transformers. The dual voltage options are a nice touch for added flexibility. Overall, these testers are functional tools for professionals who need basic testing capabilities.
Was this review helpful? Yes No (0/0)
Dual Functionality
5
Draven
Avatar
11/23/2023 6:34 PM
The CT PT Analyzer offers dual functionality, allowing users to test both current transformers and potential transformers.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews