AC/DC Clamp Meter 600 amp, True RMS/Capacitance/Temperature Function

$113.29
$125.88
The AC/DC clamp meter is a digital clamp multimeter can be used to measuring AC/DC current 0-600A, AC/DC voltage 0-600V, resistance 0-20MΩ, capacitance 0-100mF, temperature -50℃~+1000℃ (-58℉~1832℉) and frequency 0-100kHz. The maximum jaw opening size is 36mm. Digital AC/DC clamp meter has special functions of True RMS, peak hold, overload protection and LED torch.
SKU: ATO-CLAM-2018D
Free Shipping
Delivery date: 6-12 days

Clamp meter has AC/DC current (inrush current) range 0-600A, TRMS/temperature/capacitance functions, maximum jaw opening size 36mm, 4 digit display and maximum value 5999.

Specification:

BasicsModelATO-UA2018D
Weight530g
Size (L*W*H)210*78*35mm
Display4 digit LCD display
Maximum display value5999
Power supplyDC 4.5V, 3 AAA batteries
Maximum jaw opening size36mm
Woring environmentTemperature: 5℃~35℃ (41℉~95℉), relative humidity:<75%
Storage temperature-10℃~+50℃ (14℉~122℉)
AccessoriesA pair of test probes, a pair of temperature probes, a user manual, 3 AAA batteries
FunctionsItemRangeAccuracy
DC current600A±(2.0%+8 digits)
AC current600A±(2.5%+8 digits)
Inrush current600A±(5.0%+60 digits)
DC voltage600V±(0.8%+5 digits)
AC voltage600V±(1.0%+5 digits)
Resistance20MΩ±(0.8%+3 digits)
Frequency100kHz±(3.0%+3 digits)
Capacitance100mF±(3.0%+5 digits)
Temperature-40℃~+1000℃ (-40℉~1832℉)±(1.0%+4 digits)
Special functionsTRMSTrue RMS measurement for sine wave signal
Diode testDisplay forward voltage value of diode
On-off buzzerContinuity test buzzer
Data holdHold the reading when taking a measurement
Automatic power offAutomatic power off when 15 minutes no operation
Overload protectionOverload protection for 100% range
Range selectionAutomatic range selection and manual range selection
BacklightBacklight for LCD display
Inspection lightInspection light for clamp operation
LED torchA LED torch for night lighting

Details

600A AC Current Clamp Meter Details

Tips: How to use capacitance function of a clamp meter?
To avoid damage the clamp meter or the device under test, disconnect all power supply to the circuit under test and fully discharge all high-voltage capacitors before measuring capacitance. Use DC voltage function to determine the capacitor has been discharged.

  1. Turn the rotate dial to capacitance function.
  2. nsert the black test lead into the COM jack, and the red test lead into the capacitance jack.
  3. After the capacitor is fully discharged, connect the other end of the red and black test leads to the two ends of the capacitor under test. The measured capacitance value is read by the LCD display.

Note:

  1. To improve the accuracy of measurements below 10nF, subtract the distribution capacitance of the meter and leads.
  2. When measuring large capacitance, stable reading takes a certain amount of time.
  3. When measuring polar capacitor, pay attention to the corresponding polarity to avoid damaging the instrument.

 

Clamp Meter: Your Ultimate Tool for Electrical Testing

Learn how a clamp meter works and why it's an essential device for safe and efficient electrical troubleshooting.

Why a Clamp Meter is Essential for You?

Discover why a clamp meter is the ultimate tool for diagnosing and measuring electrical systems with ease and precision.

Product reviews
Accurate AC/DC clamp meter
5
Jodiodo
Avatar
11/15/2021 12:23 AM
I really like the accuracy of this AC/DC clamp meter. I compared it with the meter I used before, and its measurement results are very accurate. I haven't used it yet, but it looks very durable. All in all, I am very satisfied with it.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Clamp meter has AC/DC current (inrush current) range 0-600A, TRMS/temperature/capacitance functions, maximum jaw opening size 36mm, 4 digit display and maximum value 5999.

Specification:

BasicsModelATO-UA2018D
Weight530g
Size (L*W*H)210*78*35mm
Display4 digit LCD display
Maximum display value5999
Power supplyDC 4.5V, 3 AAA batteries
Maximum jaw opening size36mm
Woring environmentTemperature: 5℃~35℃ (41℉~95℉), relative humidity:<75%
Storage temperature-10℃~+50℃ (14℉~122℉)
AccessoriesA pair of test probes, a pair of temperature probes, a user manual, 3 AAA batteries
FunctionsItemRangeAccuracy
DC current600A±(2.0%+8 digits)
AC current600A±(2.5%+8 digits)
Inrush current600A±(5.0%+60 digits)
DC voltage600V±(0.8%+5 digits)
AC voltage600V±(1.0%+5 digits)
Resistance20MΩ±(0.8%+3 digits)
Frequency100kHz±(3.0%+3 digits)
Capacitance100mF±(3.0%+5 digits)
Temperature-40℃~+1000℃ (-40℉~1832℉)±(1.0%+4 digits)
Special functionsTRMSTrue RMS measurement for sine wave signal
Diode testDisplay forward voltage value of diode
On-off buzzerContinuity test buzzer
Data holdHold the reading when taking a measurement
Automatic power offAutomatic power off when 15 minutes no operation
Overload protectionOverload protection for 100% range
Range selectionAutomatic range selection and manual range selection
BacklightBacklight for LCD display
Inspection lightInspection light for clamp operation
LED torchA LED torch for night lighting

Details

600A AC Current Clamp Meter Details

Tips: How to use capacitance function of a clamp meter?
To avoid damage the clamp meter or the device under test, disconnect all power supply to the circuit under test and fully discharge all high-voltage capacitors before measuring capacitance. Use DC voltage function to determine the capacitor has been discharged.

  1. Turn the rotate dial to capacitance function.
  2. nsert the black test lead into the COM jack, and the red test lead into the capacitance jack.
  3. After the capacitor is fully discharged, connect the other end of the red and black test leads to the two ends of the capacitor under test. The measured capacitance value is read by the LCD display.

Note:

  1. To improve the accuracy of measurements below 10nF, subtract the distribution capacitance of the meter and leads.
  2. When measuring large capacitance, stable reading takes a certain amount of time.
  3. When measuring polar capacitor, pay attention to the corresponding polarity to avoid damaging the instrument.

 

Product reviews
Accurate AC/DC clamp meter
5
Jodiodo
Avatar
11/15/2021 12:23 AM
I really like the accuracy of this AC/DC clamp meter. I compared it with the meter I used before, and its measurement results are very accurate. I haven't used it yet, but it looks very durable. All in all, I am very satisfied with it.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews