3-phase autotransformer uses copper or aluminum winding, rated capacity 75 kVA, steps down the primary voltage 380V to secondary 220/200V, frequency 50/60 Hz, self-cooling or wind-cooled. Winding of the dry type auto-transformer has ≥98% high efficiency, other input/output voltages are customizable.
SKU: ATO-T-ASG75KVA
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

Affordable price 75 kVA dry type autotransformer for sale, three phase, which has 380 volt input voltage and 220/200 volt output voltage, primary and secondary windings are isolated separately. The step down auto-transformer has copper or aluminum wires for selection, cooling mode is self-cooled or wind-cooled.

Applications: The 3-phase autotransformer can be used in CNC production equipment, SMT, printing machines, electrical discharge machines, automatic plug-in machines, precision measuring equipment, laser cutting machines, plastic molding machines, medical monitoring systems, PCB drilling machines, laboratory equipment, military use Instrumentation control center, etc.

Specification

ModelATO-ASG75KVA
Phase3-Phase
Capacity75 kVA
Input VoltageAC 380V
Input Current114A
Output Voltage (Optional)AC 220V, 200V
Output Current197A (220V), 217A (200V)
Frequency50Hz / 60Hz
Winding Material (Optional)Aluminum Wire, Copper Wire
Cooling MethodSelf-Cooling or Wind-Cooling
Working Efficiency≥98%
Protection GradeIP21
Waveform DistortionNo distortion (compared with output wave)
Insulation Resistance≥ 150MΩ
WiringYn0
Electrical StrengthPower frequency sinusoidal voltage 3000V lasts for 1 minute, no breakdown and flicker
Overload ProtectionCan withstand instantaneous 2 times the rated current
Moisture-Proof Type (Optional)Open type, sealed type
Ambient Temperature-20℃ ~ +45℃
Altitude≤ 2500m
Relative Humidity0-95%
Noise≤35dB (within 1 meter)
Design Service Life20 years
Use EnvironmentNo explosion, rain and snow corrosion place, and no gas and conductive dust in the medium that can corrode metal and damage insulation
Weight (Enclosure Included)350 kg
Dimension600*550*750 mm

Features

  • 3-phase autotransformer has enough power, the wiring is tight and neat, and does not skip turns. Coils adopt insulated H-class enameled wire, with low no-load current and low loss.
  • The 75 kVA dry-type autotransformer has built-in silicon steel sheet, which has good magnetic flux performance, high heat dissipation coefficient and low magnetic loss.
  • The autotransformer uses electrophoresis technology clamps, no burrs on the edges, rounded corners to prevent collisions, and not easy to corrode.
  • Tinned copper tube terminals and rail-type wiring ports are convenient for wiring and ensure that the power-on overload capacity is increased to the extreme.

Details

75 kVA 3-phase autotransformer details

75 kVA 3-Phase Autotransformer Schematic Wiring Diagram

3-Phase Autotransformer Schematic Wiring Diagram

Tips: Precautions for using 75 kVA 3-phase autotransformer.

  1. The electrical performance debugging is conducted based on the national standards and the ANSI standards. The TRUE RMS voltmeter is used for debugging.
  2. Do not open the chassis by yourself, otherwise we will not provide the free warranty.
  3. 75 kVA 3-phase autotransformer manufactured by manufacturer, within the rated power range, can be applied to any AC electrical equipment.
  4. The 75 kVA 3-phase autotransformer has a certain amount of heating during application, which would be a normal phenomenon. However, the installing environment must be well ventilated and clean, in particular, the ventilation holes must not be blocked. In the event of abnormal conditions occur during use, the mains supply and main switch of 3-phase autotransformer must be shut down immediately.
  5. Power off the switching power supply of 75 kVA 3-phase autotransformer when it is not used for a long time. Keep it clean. When it is used later, the professional is required to check the stains deposited on the coils, terminals, etc.
  6. Installation and use of the 75 kVA 3-phase autotransformer shall be made by following strictly the manual.
  7. Please keep the user manual properly for future reference.
Product reviews
This autotransformer is easy to work with
5
Tucker
Avatar
9/16/2026 7:43 PM
From an installation point of view, the neatly arranged terminals were helpful. Our electrician had no trouble making the connections, and the 380V input matched our existing supply. The 220V output is now used for our production equipment, with no noticeable waveform problems during operation.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Affordable price 75 kVA dry type autotransformer for sale, three phase, which has 380 volt input voltage and 220/200 volt output voltage, primary and secondary windings are isolated separately. The step down auto-transformer has copper or aluminum wires for selection, cooling mode is self-cooled or wind-cooled.

Applications: The 3-phase autotransformer can be used in CNC production equipment, SMT, printing machines, electrical discharge machines, automatic plug-in machines, precision measuring equipment, laser cutting machines, plastic molding machines, medical monitoring systems, PCB drilling machines, laboratory equipment, military use Instrumentation control center, etc.

Specification

ModelATO-ASG75KVA
Phase3-Phase
Capacity75 kVA
Input VoltageAC 380V
Input Current114A
Output Voltage (Optional)AC 220V, 200V
Output Current197A (220V), 217A (200V)
Frequency50Hz / 60Hz
Winding Material (Optional)Aluminum Wire, Copper Wire
Cooling MethodSelf-Cooling or Wind-Cooling
Working Efficiency≥98%
Protection GradeIP21
Waveform DistortionNo distortion (compared with output wave)
Insulation Resistance≥ 150MΩ
WiringYn0
Electrical StrengthPower frequency sinusoidal voltage 3000V lasts for 1 minute, no breakdown and flicker
Overload ProtectionCan withstand instantaneous 2 times the rated current
Moisture-Proof Type (Optional)Open type, sealed type
Ambient Temperature-20℃ ~ +45℃
Altitude≤ 2500m
Relative Humidity0-95%
Noise≤35dB (within 1 meter)
Design Service Life20 years
Use EnvironmentNo explosion, rain and snow corrosion place, and no gas and conductive dust in the medium that can corrode metal and damage insulation
Weight (Enclosure Included)350 kg
Dimension600*550*750 mm

Features

  • 3-phase autotransformer has enough power, the wiring is tight and neat, and does not skip turns. Coils adopt insulated H-class enameled wire, with low no-load current and low loss.
  • The 75 kVA dry-type autotransformer has built-in silicon steel sheet, which has good magnetic flux performance, high heat dissipation coefficient and low magnetic loss.
  • The autotransformer uses electrophoresis technology clamps, no burrs on the edges, rounded corners to prevent collisions, and not easy to corrode.
  • Tinned copper tube terminals and rail-type wiring ports are convenient for wiring and ensure that the power-on overload capacity is increased to the extreme.

Details

75 kVA 3-phase autotransformer details

75 kVA 3-Phase Autotransformer Schematic Wiring Diagram

3-Phase Autotransformer Schematic Wiring Diagram

Tips: Precautions for using 75 kVA 3-phase autotransformer.

  1. The electrical performance debugging is conducted based on the national standards and the ANSI standards. The TRUE RMS voltmeter is used for debugging.
  2. Do not open the chassis by yourself, otherwise we will not provide the free warranty.
  3. 75 kVA 3-phase autotransformer manufactured by manufacturer, within the rated power range, can be applied to any AC electrical equipment.
  4. The 75 kVA 3-phase autotransformer has a certain amount of heating during application, which would be a normal phenomenon. However, the installing environment must be well ventilated and clean, in particular, the ventilation holes must not be blocked. In the event of abnormal conditions occur during use, the mains supply and main switch of 3-phase autotransformer must be shut down immediately.
  5. Power off the switching power supply of 75 kVA 3-phase autotransformer when it is not used for a long time. Keep it clean. When it is used later, the professional is required to check the stains deposited on the coils, terminals, etc.
  6. Installation and use of the 75 kVA 3-phase autotransformer shall be made by following strictly the manual.
  7. Please keep the user manual properly for future reference.
Product reviews
This autotransformer is easy to work with
5
Tucker
Avatar
9/16/2026 7:43 PM
From an installation point of view, the neatly arranged terminals were helpful. Our electrician had no trouble making the connections, and the 380V input matched our existing supply. The 220V output is now used for our production equipment, with no noticeable waveform problems during operation.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews