7100 Nm Drum Gear Coupling, 4800 rpm

$996.87
The 7100 Nm drum gear coupling has a compact design and can be easily installed in a variety of applications, allowing speeds of up to 4800 rpm, making it the perfect solution for transmitting torque between two rotating shafts. ATO drum gear couplings have a high torque capacity and can transmit power efficiently with minimal tooth clearance.
SKU: ATO-GC-GICL6
*
*
*
Free Shipping
Delivery date: 6-12 days

The drum gear coupling provides a highly durable and reliable coupling, ideal for heavy-duty industrial applications. ATO drum gear couplings are designed to transmit torque and absorb shock loads, making them ideal for use in machinery subjected to high stress and vibration.

Specification

ModelATO-GC-GICL6
Nominal Torque7100 Nm
Allowable Speed4800 rpm
Shaft Hole Diameterd1, d2, dz48, 50, 55, 5660, 63, 65,70, 71, 7580, 85, 90
Shaft Hole LengthY,L112142172
J1,Z184107132
DimensionD241
D1200
A160
C64
C1352022
C2353543
Moment of Inertia0.267 kg*m2
Grease Dosage380mL
Weight48.2kg


Features

  • 7100 Nm drum gear couplings can transmit high levels of torque due to their large contact area and robust construction.
  • Drum couplings can accommodate both angular and parallel misalignments, which can help reduce wear and tear on the connected equipment.
  • Drum gear couplings require minimal maintenance, thanks to their rugged design and few moving parts.
  • Gear couplings operate with low vibration and noise, which helps to ensure smooth and efficient power transmission.
  • These gear couplings operate with low vibration and noise, which helps to ensure smooth and efficient power transmission.

Dimension (Unit: mm)

Gear coupling dimension

Drum gear coupling dimension

Applications

Gear couplings are commonly used in heavy machineries such as steel mills, mining equipment, power generation, and paper mills. Additionally, gear couplings are frequently utilized in marine applications, such as propulsion systems and winches, due to their high torque capacity and ability to handle harsh environments.

Gear coupling applications.

Tips: What causes gear coupling failure?

Gear coupling failure can occur due to various reasons, some of which are:

  • Overloading: When the coupling is subjected to excessive loads beyond its capacity, it can lead to gear coupling failure.
  • Misalignment: If the gears in the coupling are not properly aligned, it can cause excessive wear and tear, resulting in gear failure.
  • Wear and Tear: As the coupling is used over time, the gears can wear down, leading to coupling failure.
  • Improper lubrication: Inadequate lubrication can cause the gears to overheat, leading to gear damage and eventually failure.
  • Corrosion: If the gear coupling is exposed to corrosive environments, it can cause the gears to deteriorate and fail.
  • Fatigue failure: Repeated loading and unloading can cause the gears to develop cracks, leading to gear coupling failure.
  • Manufacturing defects: If the gear coupling has any defects in its design or manufacturing, it can lead to premature failure of the coupling.

It's important to ensure proper maintenance and inspection of gear couplings to prevent failure and avoid costly downtime.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The drum gear coupling provides a highly durable and reliable coupling, ideal for heavy-duty industrial applications. ATO drum gear couplings are designed to transmit torque and absorb shock loads, making them ideal for use in machinery subjected to high stress and vibration.

Specification

ModelATO-GC-GICL6
Nominal Torque7100 Nm
Allowable Speed4800 rpm
Shaft Hole Diameterd1, d2, dz48, 50, 55, 5660, 63, 65,70, 71, 7580, 85, 90
Shaft Hole LengthY,L112142172
J1,Z184107132
DimensionD241
D1200
A160
C64
C1352022
C2353543
Moment of Inertia0.267 kg*m2
Grease Dosage380mL
Weight48.2kg


Features

  • 7100 Nm drum gear couplings can transmit high levels of torque due to their large contact area and robust construction.
  • Drum couplings can accommodate both angular and parallel misalignments, which can help reduce wear and tear on the connected equipment.
  • Drum gear couplings require minimal maintenance, thanks to their rugged design and few moving parts.
  • Gear couplings operate with low vibration and noise, which helps to ensure smooth and efficient power transmission.
  • These gear couplings operate with low vibration and noise, which helps to ensure smooth and efficient power transmission.

Dimension (Unit: mm)

Gear coupling dimension

Drum gear coupling dimension

Applications

Gear couplings are commonly used in heavy machineries such as steel mills, mining equipment, power generation, and paper mills. Additionally, gear couplings are frequently utilized in marine applications, such as propulsion systems and winches, due to their high torque capacity and ability to handle harsh environments.

Gear coupling applications.

Tips: What causes gear coupling failure?

Gear coupling failure can occur due to various reasons, some of which are:

  • Overloading: When the coupling is subjected to excessive loads beyond its capacity, it can lead to gear coupling failure.
  • Misalignment: If the gears in the coupling are not properly aligned, it can cause excessive wear and tear, resulting in gear failure.
  • Wear and Tear: As the coupling is used over time, the gears can wear down, leading to coupling failure.
  • Improper lubrication: Inadequate lubrication can cause the gears to overheat, leading to gear damage and eventually failure.
  • Corrosion: If the gear coupling is exposed to corrosive environments, it can cause the gears to deteriorate and fail.
  • Fatigue failure: Repeated loading and unloading can cause the gears to develop cracks, leading to gear coupling failure.
  • Manufacturing defects: If the gear coupling has any defects in its design or manufacturing, it can lead to premature failure of the coupling.

It's important to ensure proper maintenance and inspection of gear couplings to prevent failure and avoid costly downtime.

Only registered users can write reviews