4 Digit Display Controller for Load Cells

$244.60
Low price 4-digit display controller, with 100-240V AC voltage, is an electronic device designed to interface with various sensors, particularly load cells, for precise measurement and digital readouts. This compact digital panel meter typically incorporates a microcontroller and a 4-digit LCD display, optional analog output of 4-20mA, 0-10mA, 0-20mA, 1-5V and 0-5V.
SKU: ATO-DDC-CHB2
*
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

The primary function of the 4 digital display controller is to process analog signals from load cells, converting them into digital readings for easy interpretation. These controllers are often employed in weighing systems, industrial applications, or any scenario where accurate measurement of weight or force is essential.

Specification

ModelATO-CHB2-160x80
PDF Download4 Digit Display Controller User Manual
VoltageAC Power100-240V AC 50/60 Hz
AC/DC Power10-24V AC 50/60 Hz, 10-24V DC
Consumption PowerAC PowerBelow 7VA
AC/DC PowerAC: Below6VA, DC: Below 5W
Allowable Voltage Variation Range90~110% of Power Supply Voltage
Insulation Resistance100MΩ or More (500V DC MEGA Standard)
Withstand Voltage1 Minute at 2000V AC 50/60 Hz
Anti-InterferenceIEC61000-4-2 (electrostatic discharge), level III
IEC61000-4-4 (Electrical Fast Transient Burst), Level III
IEC61000-4-5 (Surge), level III
Protection GradeIP65 (Front Part of the Digital Panel Meter)
Ambient Temperature10~55℃, Storage: -25~65℃
Environmental Humidity35~85%RH, Storage: 35~85%RH
Dimension160x80x125mm
Measurement Control SpeedMore Than 10 times/second
Basic Error±0.2%F.S
Display Range-1999~9999
Input SignalVoltage V0-5V DC, 1-5V DC
Current I4-20/0-10/0-20 mA
mV M±20, ±50, ±90mV
Digital FilteringInertia, Average, Moving Average, etc.
Contact OutputA1-A41-4 points, 250VAC/3A Resistive Load
Contact InputK1 External Binary Input for Clearing
Analog Output (Resolution 1/3000)M1Current Output: 4-20mA, 0-10mA, 0-20mA
M2Voltage Output: 1-5V, 0-5V
Communication InterfaceC1TC ASCⅡ Protocol RS232
C2TC ASCⅡ Protocol RS485
R1Modbus-RTU Protocol RS232
R2Modbus-RTU Protocol RS485
External Power SupplyP124V±5%, Below 50mA
P1G24V±5%, Below 100mA
P212V±5%, Below 50mA
P2G12V±5%, Below 100mA
P3Precision Power Supply, 10V±2%, Below 30ppm, 100mA


Dimension (Unit: mm)

4 digit display controller dimension

abcdefg
16080101157515276


Wiring Diagram

4 digit display controller wiring

Tips: 4 digit display controller for load cells

A 4 digit display controller serves as a vital interface between load cells and users. It interprets the signals received from load cells, which measure force or weight, and presents this data in a user-friendly numerical format on a 4 digit display. Load cells convert mechanical force into electrical signals, but these signals require interpretation for meaningful human understanding.

The controller processes the analog signals from load cells, performs necessary conversions, and then showcases the resultant weight or force measurement on the digital display. It enhances usability by enabling users to conveniently read and interpret the weight or force values captured by the load cells. Additionally, such controllers often include features like calibration options, signal filtering, and display settings, ensuring accurate and calibrated readings for various applications, such as industrial scales, laboratory equipment, or other systems where precise weight measurement is critical.

This digital panel meter can provide accurate readings for load cells, force sensors and weighing sensors, suitable for measuring pressure, impact force, tension and weight.

This video shows the connection and setting of the digital display controller with S type load cell.

Load Cell Controller Setup and Calibration

In this video, we select an S-type load cell and a 2kg standard weight to complete the setup and calibration. Finally, ATO also shows you how to set the tare value and measure the tare weight.

Product reviews
Panel display weight unit
5
Mariend
Avatar
3/18/2025 7:20 PM
Can the ATO-CHB2 panel display LBS and KGs?
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, regarding the ATO-CHB2 panel you mentioned, it does not directly support the display of weight units on the panel. If you want to display in LBS, you need to calibrate the load cell in LBS.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The primary function of the 4 digital display controller is to process analog signals from load cells, converting them into digital readings for easy interpretation. These controllers are often employed in weighing systems, industrial applications, or any scenario where accurate measurement of weight or force is essential.

Specification

ModelATO-CHB2-160x80
PDF Download4 Digit Display Controller User Manual
VoltageAC Power100-240V AC 50/60 Hz
AC/DC Power10-24V AC 50/60 Hz, 10-24V DC
Consumption PowerAC PowerBelow 7VA
AC/DC PowerAC: Below6VA, DC: Below 5W
Allowable Voltage Variation Range90~110% of Power Supply Voltage
Insulation Resistance100MΩ or More (500V DC MEGA Standard)
Withstand Voltage1 Minute at 2000V AC 50/60 Hz
Anti-InterferenceIEC61000-4-2 (electrostatic discharge), level III
IEC61000-4-4 (Electrical Fast Transient Burst), Level III
IEC61000-4-5 (Surge), level III
Protection GradeIP65 (Front Part of the Digital Panel Meter)
Ambient Temperature10~55℃, Storage: -25~65℃
Environmental Humidity35~85%RH, Storage: 35~85%RH
Dimension160x80x125mm
Measurement Control SpeedMore Than 10 times/second
Basic Error±0.2%F.S
Display Range-1999~9999
Input SignalVoltage V0-5V DC, 1-5V DC
Current I4-20/0-10/0-20 mA
mV M±20, ±50, ±90mV
Digital FilteringInertia, Average, Moving Average, etc.
Contact OutputA1-A41-4 points, 250VAC/3A Resistive Load
Contact InputK1 External Binary Input for Clearing
Analog Output (Resolution 1/3000)M1Current Output: 4-20mA, 0-10mA, 0-20mA
M2Voltage Output: 1-5V, 0-5V
Communication InterfaceC1TC ASCⅡ Protocol RS232
C2TC ASCⅡ Protocol RS485
R1Modbus-RTU Protocol RS232
R2Modbus-RTU Protocol RS485
External Power SupplyP124V±5%, Below 50mA
P1G24V±5%, Below 100mA
P212V±5%, Below 50mA
P2G12V±5%, Below 100mA
P3Precision Power Supply, 10V±2%, Below 30ppm, 100mA


Dimension (Unit: mm)

4 digit display controller dimension

abcdefg
16080101157515276


Wiring Diagram

4 digit display controller wiring

Tips: 4 digit display controller for load cells

A 4 digit display controller serves as a vital interface between load cells and users. It interprets the signals received from load cells, which measure force or weight, and presents this data in a user-friendly numerical format on a 4 digit display. Load cells convert mechanical force into electrical signals, but these signals require interpretation for meaningful human understanding.

The controller processes the analog signals from load cells, performs necessary conversions, and then showcases the resultant weight or force measurement on the digital display. It enhances usability by enabling users to conveniently read and interpret the weight or force values captured by the load cells. Additionally, such controllers often include features like calibration options, signal filtering, and display settings, ensuring accurate and calibrated readings for various applications, such as industrial scales, laboratory equipment, or other systems where precise weight measurement is critical.

Product reviews
Panel display weight unit
5
Mariend
Avatar
3/18/2025 7:20 PM
Can the ATO-CHB2 panel display LBS and KGs?
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, regarding the ATO-CHB2 panel you mentioned, it does not directly support the display of weight units on the panel. If you want to display in LBS, you need to calibrate the load cell in LBS.
Only registered users can write reviews
Customers who bought this item also bought

Tension and Compression Load Cell, 1 kg - 500 kg

ATO-LC-TC01
$137.98
Tension and compression load cell can bear both tension and pressure, with good anti-eccentric load performance, low height, all sealed structure and complete specifications. Miniature load cell with optional capacity 1 kg/ 100kg/ 200 kg/ 300kg/ 500 kg is suited to use in restricted spaces, such as using in vehicle/test instrument/laminator measurement and control.

Load Cell Junction Box for Scales, 2/3/4/6/8/10 Inlets to 1 Outlet

ATO-LCBOX-10I
$66.67
Multi-channel load cell junction box has 2/3/4/6/8/10 inlets and 1 outlet, aluminum alloy casing, good anti-interference, special for waterproof sealing joint, waterproof and dustproof rubber gasket for cover, easy to assemble and debug. Each channel can be adjusted balance to prevent damage to the sensor caused by inductive lightning and surge signals.

Tension and Compression Load Cell, 100kg/1 ton/2 ton to 20 ton

ATO-LC-S05
$104.29
Tension and compression load cell can bear both tension and pressure, with good output symmetry, high eccentric load resistant, compact structure and complete specifications. Strain gauge load cell can be applied for batching scale, crane scales and other special weighing instruments.