3kVA/2400W battery backup is a line interactive uninterruptible power supply for home, office and business. 3000VA UPS has selectable 220V/120V AC input and output voltages with LCD display and overload protection, reliable power source for networks, personal computers and other peripherals during power outage.
SKU: ATO-UPS-3K
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-20 days

Applications

3000VA/2400 Watts UPS is an uninterruptible power supply to provide emergency power to a load, and it is mainly used in computer, office equipment, test equipment, light system, safe alarm system, ray equipment, medical equipment, copymachine, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment etc.

3kVA UPS Specification

BasicsModelATO-BE-3K
PhaseSingle phase with ground
Capacity3000 VA/2400 W
InputNominal Voitage100/110/115/120/127VAC or 200/208/220/230/240VAC
Input Voltage Range55-150VAC or 110-300 VAC (Based on load at 50%)
85-140VAC or 160-280VAC (Based on load at 100%)
Frequency Range40Hz-70Hz
Power Factor≥0.99 @ Nominall voltage (100% load)
OutputOutput Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage Regulation±1%
Frequency Range (Synchronized Range)47-53Hz or 57-63Hz
Frequency Range (Batt. Mode)50Hz±0.25Hz or 60Hz±0.3Hz
Current Crest Ratio3:1
Harmonic Distortion≤3% THD (Linear Load)
≤6% THD (Non-linear Load)
Transfer TimeAC Mode to Battery ModeZero
Inverter to Bypass4 ms (Typical)
Waveform (Batt. Mode)Pure Sinewave
EfficiencyAC Mode90%
Battery Mode88%
BatteryStandard ModelBattery Type12V / 9Ah
Numbers6
Typical Recharge Time4 hours recover to 90% capacity
Charging Current (max.)1A
Charging Voltage82.1VDC ±1%
Long-run ModelBattery TypeDepending on the capacity of external batteries
Numbers68
Charging Current (max.)1A/2A/4A/6A (Adjustable)
Charging Voltage82.1VDC±1%109.4VDC±1%
IndicatorsLCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
AlarmBattery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
PhysicalLong-run ModelDimension, DxWxH (mm)397x145x220
Net Weight (kgs)7.4
EnvironmentHumidity20-90% RH @ 0-40°C (Non-condensing)
Noise LevelLess than 50dB @ 1 Meter
ManagementSmart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser

Note:

1. The UPS input/output configuration is 1-phase (L, N, G) like Europe standard, NOT support the split phase (L1, L2 + G) like USA standard.

2. Batteries that work with this UPS are not included, customers need to match lead-acid battery packs on their own, consult us for battery specifications.

3. If you need other output voltage range, please contact us.

Details

Backup uninterruptible power supply 3k details

  1. AC input
  2. Input circuit breaker
  3. USB communication port
  4. RS-232 communication port
  5. SNMP intelligent slot (option)
  6. External battery connection (only available for L model)
  7. Output receptacles
  8. Output terminal

Tips: How to select an uninterruptible power supply (UPS)?

1. Stability
Because UPS power supply plays a role of safeguard, its own stability is more important. Therefore, the quality of the product is the first principle for users to select an uninterruptible power supply.

2. Back-up time
Back-up time is an index that many users will pay attention to when purchasing an UPS power supply. On one hand, the UPS battery backup continues to supply power for users after power failure. On the other hand, it ensures that users can have a clean power supply and protect the user's equipment.

3. Type of UPS power supply
It is necessary to determine the online, online interactive, standby type, sine wave, square wave and other type of UPS according to the load requirement for output stability, switching time and output wave form.

4. Service ability
Users’ network characteristics and electric power environment are different. Their demand for power protection also changes greatly. Users may encounter various problems when using an UPS power supply and users want to buy products and services that are fully suitable for actual needs.

5. Accessory function
It is recommended to adopt UPS thermal backup system in order to improve the reliability of the system, which can have series connection or parallel connection with warm backup. The uninterruptible power supply with small capacity (1 ~2KVA) can also select redundancy switch. The remote monitoring panel can be used to monitor and control the UPS work at the far end.

UPS for Computer Backup Power

In this video, the process of how to use UPS as a computer backup power supply is shown.

Product reviews
Installation of 3000VA UPS uninterruptible power supply
5
Jebby
Avatar
6/18/2021 3:04 AM
How do I install this 3000VA UPS uninterruptible power supply?
Was this review helpful? Yes No (0/0)
ATO Responded
Video of installing 3000VA UPS uninterruptible power supply: https://www.youtube.com/watch?v=5HeU-rkry-0
Not bad
5
Beyette
Avatar
4/27/2022 9:39 PM
I should have bought it earlier. It's a hassle for me when you cut off the power while you're sending an email. 3000VA uninterruptible power supply gives me some time to save my data after a power outage.
Was this review helpful? Yes No (0/0)
We would need an external battery pack
5
Diggle
Avatar
12/17/2024 6:13 PM
Hello, some time ago we bought from you an uninterruptible power supply in a version for 220V. Now we would need an external battery pack for this device. Could you please help us with the specification of an external battery that would be suitable for this device? Or if you have a product in your portfolio suitable for our UPS, please let us know.
Was this review helpful? Yes No (0/0)
ATO Responded
How long do you need the battery to work for? If it is 1 hour, a 38ah battery is required.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Applications

3000VA/2400 Watts UPS is an uninterruptible power supply to provide emergency power to a load, and it is mainly used in computer, office equipment, test equipment, light system, safe alarm system, ray equipment, medical equipment, copymachine, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment etc.

3kVA UPS Specification

BasicsModelATO-BE-3K
PhaseSingle phase with ground
Capacity3000 VA/2400 W
InputNominal Voitage100/110/115/120/127VAC or 200/208/220/230/240VAC
Input Voltage Range55-150VAC or 110-300 VAC (Based on load at 50%)
85-140VAC or 160-280VAC (Based on load at 100%)
Frequency Range40Hz-70Hz
Power Factor≥0.99 @ Nominall voltage (100% load)
OutputOutput Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage Regulation±1%
Frequency Range (Synchronized Range)47-53Hz or 57-63Hz
Frequency Range (Batt. Mode)50Hz±0.25Hz or 60Hz±0.3Hz
Current Crest Ratio3:1
Harmonic Distortion≤3% THD (Linear Load)
≤6% THD (Non-linear Load)
Transfer TimeAC Mode to Battery ModeZero
Inverter to Bypass4 ms (Typical)
Waveform (Batt. Mode)Pure Sinewave
EfficiencyAC Mode90%
Battery Mode88%
BatteryStandard ModelBattery Type12V / 9Ah
Numbers6
Typical Recharge Time4 hours recover to 90% capacity
Charging Current (max.)1A
Charging Voltage82.1VDC ±1%
Long-run ModelBattery TypeDepending on the capacity of external batteries
Numbers68
Charging Current (max.)1A/2A/4A/6A (Adjustable)
Charging Voltage82.1VDC±1%109.4VDC±1%
IndicatorsLCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
AlarmBattery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
PhysicalLong-run ModelDimension, DxWxH (mm)397x145x220
Net Weight (kgs)7.4
EnvironmentHumidity20-90% RH @ 0-40°C (Non-condensing)
Noise LevelLess than 50dB @ 1 Meter
ManagementSmart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser

Note:

1. The UPS input/output configuration is 1-phase (L, N, G) like Europe standard, NOT support the split phase (L1, L2 + G) like USA standard.

2. Batteries that work with this UPS are not included, customers need to match lead-acid battery packs on their own, consult us for battery specifications.

3. If you need other output voltage range, please contact us.

Details

Backup uninterruptible power supply 3k details

  1. AC input
  2. Input circuit breaker
  3. USB communication port
  4. RS-232 communication port
  5. SNMP intelligent slot (option)
  6. External battery connection (only available for L model)
  7. Output receptacles
  8. Output terminal

Tips: How to select an uninterruptible power supply (UPS)?

1. Stability
Because UPS power supply plays a role of safeguard, its own stability is more important. Therefore, the quality of the product is the first principle for users to select an uninterruptible power supply.

2. Back-up time
Back-up time is an index that many users will pay attention to when purchasing an UPS power supply. On one hand, the UPS battery backup continues to supply power for users after power failure. On the other hand, it ensures that users can have a clean power supply and protect the user's equipment.

3. Type of UPS power supply
It is necessary to determine the online, online interactive, standby type, sine wave, square wave and other type of UPS according to the load requirement for output stability, switching time and output wave form.

4. Service ability
Users’ network characteristics and electric power environment are different. Their demand for power protection also changes greatly. Users may encounter various problems when using an UPS power supply and users want to buy products and services that are fully suitable for actual needs.

5. Accessory function
It is recommended to adopt UPS thermal backup system in order to improve the reliability of the system, which can have series connection or parallel connection with warm backup. The uninterruptible power supply with small capacity (1 ~2KVA) can also select redundancy switch. The remote monitoring panel can be used to monitor and control the UPS work at the far end.

Product reviews
Installation of 3000VA UPS uninterruptible power supply
5
Jebby
Avatar
6/18/2021 3:04 AM
How do I install this 3000VA UPS uninterruptible power supply?
Was this review helpful? Yes No (0/0)
ATO Responded
Video of installing 3000VA UPS uninterruptible power supply: https://www.youtube.com/watch?v=5HeU-rkry-0
Not bad
5
Beyette
Avatar
4/27/2022 9:39 PM
I should have bought it earlier. It's a hassle for me when you cut off the power while you're sending an email. 3000VA uninterruptible power supply gives me some time to save my data after a power outage.
Was this review helpful? Yes No (0/0)
We would need an external battery pack
5
Diggle
Avatar
12/17/2024 6:13 PM
Hello, some time ago we bought from you an uninterruptible power supply in a version for 220V. Now we would need an external battery pack for this device. Could you please help us with the specification of an external battery that would be suitable for this device? Or if you have a product in your portfolio suitable for our UPS, please let us know.
Was this review helpful? Yes No (0/0)
ATO Responded
How long do you need the battery to work for? If it is 1 hour, a 38ah battery is required.
Only registered users can write reviews