10kVA 120V/220V UPS Backup Uninterruptible Power Supply

$3,565.87
Uninterruptible Power Supply, 10kVA/8kW, line interactive UPS, provides a reliable battery backup for critical devices like PCs, servers, and networks against power surges and outages. High reliability yet low-cost 10kVA UPS is available with input and output voltages of AC 220V/120V for choice.
SKU: ATO-UPS-10K
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-20 days

Applications

10kVA/8000 Watts UPS is an uninterruptible power supply to provide emergency power to a load, and it is mainly used in computers, office equipment, test equipment, light systems, safe alarm systems, ray equipment, medical equipment, copy machines, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment, etc.

10kVA/8000W UPS Specification

BasicsModelATO-BE-10K
Rated Capacity10000VA/8000W
PhaseSingle Phase (L, N, G) * NOT support the split phase (L1, L2 + G) like USA standard.
Weight (kgs)16
Dimension (mm)442×190×318
InputNominal Voltage208/220/230/240VAC
Input Voltage Range110-300 VAC (Based on load at 50%), 176-300 VAC (Based on load at 100%)
Frequency Range46-54 Hz or 56-64 Hz
Power Factor≥0.99 @ Nominal Voltage (100% load)
OutputOutput Voltage208/220/230/240VAC
Voltage Regulation±1%
Frequency Range (Synchronized Range)46-54 Hz or 56-64 Hz
Current Crest Ratio50 Hz or 60 Hz ±0.1Hz
Harmonic Distortion≤3% THD (Linear Load), ≤5 % THD (Non-linear Load)
Transfer TimeZero
Waveform (Batt. Mode)Pure Sinewave
EfficiencyAC Mode93%
Battery Mode91%
BatteryStandard ModelBattery Type12V / 9Ah
Numbers1620
Typical Recharge Time9 hours recover to 90% capacity
Charging Current (max.)1A/2A
Charging Voltage218.4VDC ±1%273 VDC ±1%
Long-run ModelBattery TypeDepending on the capacity of external batteries
Numbers16 - 20 (Adjustable)
Charging Current (Max.)1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)
Charging Voltage273 VDC ±1% (Based on 20pcs batteries)
IndicatorsLCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
AlarmBattery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
EnvironmentHumidity0-95% RH @ 0-40°C (non-condensing)
Noise LevelLess than 55dB @ 1 Meter
ManagementSmart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser

Note:

1. The UPS input/output configuration is 1-phase (L, N, G) like Europe standard, NOT support the split phase (L1, L2 + G) like USA standard.

2. Batteries that work with this UPS are not included, customers need to match lead-acid battery packs on their own, consult us for battery specifications.

3. If you need other output voltage range, please contact us.

Rear Panel Diagram

Ups diagram 6kl10kl

  1. External battery connector
  2. RS-232 communication port
  3. Intelligent slot
  4. USB communication
  5. Emergency power off function connector (EPO connector)
  6. Cooling fan
  7. Input circuit breaker
  8. Input/ Output terminal (Refer to Diagrams 3 and 6 for the details)

Tips: Troubleshooting UPS - the battery voltage is low but the battery cannot be charged for more than 10 hours.

Judging from the phenomenon, it is the fault of the battery and charging circuit, which can be inspected according to the following procedures.

  1. Check whether the input and output voltage of the UPS charging circuit is normal.
  2. If the charging circuit has normal input and abnormal output, disconnect the UPS battery to test again. If it is still abnormal, it is the fault of the charging circuit.
  3. If the charging circuit has normal input and output after the battery is disconnected, it indicates that the UPS battery has been damaged because of the long-term charging, long-term placement, and due life period.

UPS for Computer Backup Power

In this video, the process of how to use UPS as a computer backup power supply is shown.

Product reviews
10kva single phase UPS
5
Ken
Avatar
4/29/2020 7:32 PM
For your 10kva single phase UPS with input 220v frequency 50-60hz and output 220v, is it manufactured to be connected to external batteries?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi Ken. There are no restrictions on the use of external batteries, and also you can configure enough batteries to run the UPS for longer backup time than the UPS with batteries inside without any issues.
I'm looking to purchase a UPS pack...
5
Kamil
Avatar
6/1/2020 6:51 PM
I'm looking to purchase a UPS pack that can output 230v supporting 7kva computer system, with an input of 120v. Is this something you are able to supply.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide the UPS which can cover your specs as follows:
Power capacity: 10kVA
Input: 120V (90-130V)
Output: 1-phase (L, N, G) 230V
High quality 10kVA UPS
5
Voll
Avatar
8/9/2021 1:40 AM
I am interested to see if this 10kVA UPS will work with a battery bank I have already. It has 64 batteries and was designed for an Eaton 8KVA. Also open to suggestions, if you have something that might work for me to use this external battery. I can rewire the battery bank as necessary.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the customer can use his battery bank connect to our 10kva ups, no problem. If he provides more information about 64 batteries, like voltage(12VDC or 24VDC) and capacity of battery(AH), that would be better.
Batteries Price
5
abdel
Avatar
11/3/2021 4:43 PM
I am interested in this UPS on the other hand I would like to have an estimate of the price of the batteries.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, our courier can't send the battery right now.
High quality and long service life
5
zhl
Avatar
4/26/2022 7:12 PM
I used this for 3 years. It was a solid UPS that seemed to do all it was supposed to. Couldn't have been happier. Highly recommend to anyone who need it!
Was this review helpful? Yes No (0/0)
Works as expected
5
Couchman
Avatar
4/27/2022 9:52 PM
This is the first time to buy an uninterruptible power supply, and the instructions are very clear. Luckily I got it set up correctly. Since I have relatively few power outages here, I use it as a backup battery.
Was this review helpful? Yes No (0/0)
Works well!
5
Bruce
Avatar
11/1/2023 3:20 AM
The CyberPower work great for me, Id buy it again. The most important thing is that it is in perfect condition, quality and reasonable price.
Was this review helpful? Yes No (0/0)
10kVA UPS
5
Michael
Avatar
11/7/2023 11:01 PM
Now we need 2 units (10KVA each) with 480V input and 120V output 10KVA - run time at least 10 minutes. Is this the right product?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our UPS do not provide 480v input, we have No suitable product recommendations.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Applications

10kVA/8000 Watts UPS is an uninterruptible power supply to provide emergency power to a load, and it is mainly used in computers, office equipment, test equipment, light systems, safe alarm systems, ray equipment, medical equipment, copy machines, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment, etc.

10kVA/8000W UPS Specification

BasicsModelATO-BE-10K
Rated Capacity10000VA/8000W
PhaseSingle Phase (L, N, G) * NOT support the split phase (L1, L2 + G) like USA standard.
Weight (kgs)16
Dimension (mm)442×190×318
InputNominal Voltage208/220/230/240VAC
Input Voltage Range110-300 VAC (Based on load at 50%), 176-300 VAC (Based on load at 100%)
Frequency Range46-54 Hz or 56-64 Hz
Power Factor≥0.99 @ Nominal Voltage (100% load)
OutputOutput Voltage208/220/230/240VAC
Voltage Regulation±1%
Frequency Range (Synchronized Range)46-54 Hz or 56-64 Hz
Current Crest Ratio50 Hz or 60 Hz ±0.1Hz
Harmonic Distortion≤3% THD (Linear Load), ≤5 % THD (Non-linear Load)
Transfer TimeZero
Waveform (Batt. Mode)Pure Sinewave
EfficiencyAC Mode93%
Battery Mode91%
BatteryStandard ModelBattery Type12V / 9Ah
Numbers1620
Typical Recharge Time9 hours recover to 90% capacity
Charging Current (max.)1A/2A
Charging Voltage218.4VDC ±1%273 VDC ±1%
Long-run ModelBattery TypeDepending on the capacity of external batteries
Numbers16 - 20 (Adjustable)
Charging Current (Max.)1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)
Charging Voltage273 VDC ±1% (Based on 20pcs batteries)
IndicatorsLCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
AlarmBattery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
EnvironmentHumidity0-95% RH @ 0-40°C (non-condensing)
Noise LevelLess than 55dB @ 1 Meter
ManagementSmart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser

Note:

1. The UPS input/output configuration is 1-phase (L, N, G) like Europe standard, NOT support the split phase (L1, L2 + G) like USA standard.

2. Batteries that work with this UPS are not included, customers need to match lead-acid battery packs on their own, consult us for battery specifications.

3. If you need other output voltage range, please contact us.

Rear Panel Diagram

Ups diagram 6kl10kl

  1. External battery connector
  2. RS-232 communication port
  3. Intelligent slot
  4. USB communication
  5. Emergency power off function connector (EPO connector)
  6. Cooling fan
  7. Input circuit breaker
  8. Input/ Output terminal (Refer to Diagrams 3 and 6 for the details)

Tips: Troubleshooting UPS - the battery voltage is low but the battery cannot be charged for more than 10 hours.

Judging from the phenomenon, it is the fault of the battery and charging circuit, which can be inspected according to the following procedures.

  1. Check whether the input and output voltage of the UPS charging circuit is normal.
  2. If the charging circuit has normal input and abnormal output, disconnect the UPS battery to test again. If it is still abnormal, it is the fault of the charging circuit.
  3. If the charging circuit has normal input and output after the battery is disconnected, it indicates that the UPS battery has been damaged because of the long-term charging, long-term placement, and due life period.
Product reviews
10kva single phase UPS
5
Ken
Avatar
4/29/2020 7:32 PM
For your 10kva single phase UPS with input 220v frequency 50-60hz and output 220v, is it manufactured to be connected to external batteries?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi Ken. There are no restrictions on the use of external batteries, and also you can configure enough batteries to run the UPS for longer backup time than the UPS with batteries inside without any issues.
I'm looking to purchase a UPS pack...
5
Kamil
Avatar
6/1/2020 6:51 PM
I'm looking to purchase a UPS pack that can output 230v supporting 7kva computer system, with an input of 120v. Is this something you are able to supply.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide the UPS which can cover your specs as follows:
Power capacity: 10kVA
Input: 120V (90-130V)
Output: 1-phase (L, N, G) 230V
High quality 10kVA UPS
5
Voll
Avatar
8/9/2021 1:40 AM
I am interested to see if this 10kVA UPS will work with a battery bank I have already. It has 64 batteries and was designed for an Eaton 8KVA. Also open to suggestions, if you have something that might work for me to use this external battery. I can rewire the battery bank as necessary.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the customer can use his battery bank connect to our 10kva ups, no problem. If he provides more information about 64 batteries, like voltage(12VDC or 24VDC) and capacity of battery(AH), that would be better.
Batteries Price
5
abdel
Avatar
11/3/2021 4:43 PM
I am interested in this UPS on the other hand I would like to have an estimate of the price of the batteries.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, our courier can't send the battery right now.
High quality and long service life
5
zhl
Avatar
4/26/2022 7:12 PM
I used this for 3 years. It was a solid UPS that seemed to do all it was supposed to. Couldn't have been happier. Highly recommend to anyone who need it!
Was this review helpful? Yes No (0/0)
Works as expected
5
Couchman
Avatar
4/27/2022 9:52 PM
This is the first time to buy an uninterruptible power supply, and the instructions are very clear. Luckily I got it set up correctly. Since I have relatively few power outages here, I use it as a backup battery.
Was this review helpful? Yes No (0/0)
Works well!
5
Bruce
Avatar
11/1/2023 3:20 AM
The CyberPower work great for me, Id buy it again. The most important thing is that it is in perfect condition, quality and reasonable price.
Was this review helpful? Yes No (0/0)
10kVA UPS
5
Michael
Avatar
11/7/2023 11:01 PM
Now we need 2 units (10KVA each) with 480V input and 120V output 10KVA - run time at least 10 minutes. Is this the right product?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our UPS do not provide 480v input, we have No suitable product recommendations.
Only registered users can write reviews