3 hp (2.2 kW) DC Reactor, Single Phase

$95.79
3 hp (2.2 kW) single phase VFD reactor for sale, DC smoothing reactor in high voltage DC transmission (HVDC), rated current 10A, 220V-1200V voltage can be customized.
SKU: ATO-DCR-3
*
*
Free Shipping
Delivery date: 6-12 days

DC line reactor for vfd at affordable price, 3 hp power rating, 1 phase, improve the input current wave caused by capacitor harmonics, small size and light weight. In addition to improve the power factor, the DC reactor can also reduce the impact immediately after the power is turned on.

Specification:

ModelATO-DCL-10
Phase1 Phase
Power Adapter2.2 kW (3 hp)
VFD Voltage Adapter220V-1200V (Contact us for other voltages)
Rated Current10A
Inductance3.185mH
Insulation GradeF.H
Dimension84*110*100mm (L*W*H)
Mounting Dimension70*70mm
Electric StrengthIron core-winding 3000VAC/50Hz/10mA/60s no arcing no breakdown
Insulation Resistanceiron core-winding 1000VDC, Insulation resistance
≥100MV
Noise of ReactorLess than 35dB (measured from 1 meter away in horizon from reactor)
Degree of ProtectionIP00
Degree of Insulation> Class F
Weight2.5kg

Features
1. Improve the input current wave caused by capacitor harmonics.
2. Reduce and prevent rectifier bridge damage and capacitors.
3. Overheating due to a surge in current.
4. Improve the power factor and reduce the AC pulse of the DC bus.
5. Limit transient changes in system voltage.

Dimension (unit: mm)
DC reactor dimensionDetails

Single Phase DC Reactor Details

Tips:

In the lifting industry, since AC reactors cannot be omitted, the harmonic reduction effect of AC reactors is basically the same as that of DC reactors.
At the same time, using AC and DC reactors can reduce harmonic interference better, but it also increases the voltage loss on the motor side (there are 1% to 3% voltage drops on AC and DC reactors). Therefore, ATO recommends replacing AC reactors with AC reactors.

Product reviews
Works great for what I need!
5
Anto
Avatar
3/25/2022 3:15 AM
I love this DC reactor so much. Bravo! It is easy to use and the quality is super great. At first, I thought it would be a piece of junk. Once I use it  and I knew that I  was wrong. It really deserves a high rating!
Was this review helpful? Yes No (0/0)
Perfect reactor for my inverter system
5
Maren
Avatar
7/15/2026 7:24 PM
I was looking for a way to improve my inverter system, and this reactor solved the problem. The current response is smoother, and the whole system feels more stable during operation.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

DC line reactor for vfd at affordable price, 3 hp power rating, 1 phase, improve the input current wave caused by capacitor harmonics, small size and light weight. In addition to improve the power factor, the DC reactor can also reduce the impact immediately after the power is turned on.

Specification:

ModelATO-DCL-10
Phase1 Phase
Power Adapter2.2 kW (3 hp)
VFD Voltage Adapter220V-1200V (Contact us for other voltages)
Rated Current10A
Inductance3.185mH
Insulation GradeF.H
Dimension84*110*100mm (L*W*H)
Mounting Dimension70*70mm
Electric StrengthIron core-winding 3000VAC/50Hz/10mA/60s no arcing no breakdown
Insulation Resistanceiron core-winding 1000VDC, Insulation resistance
≥100MV
Noise of ReactorLess than 35dB (measured from 1 meter away in horizon from reactor)
Degree of ProtectionIP00
Degree of Insulation> Class F
Weight2.5kg

Features
1. Improve the input current wave caused by capacitor harmonics.
2. Reduce and prevent rectifier bridge damage and capacitors.
3. Overheating due to a surge in current.
4. Improve the power factor and reduce the AC pulse of the DC bus.
5. Limit transient changes in system voltage.

Dimension (unit: mm)
DC reactor dimensionDetails

Single Phase DC Reactor Details

Tips:

In the lifting industry, since AC reactors cannot be omitted, the harmonic reduction effect of AC reactors is basically the same as that of DC reactors.
At the same time, using AC and DC reactors can reduce harmonic interference better, but it also increases the voltage loss on the motor side (there are 1% to 3% voltage drops on AC and DC reactors). Therefore, ATO recommends replacing AC reactors with AC reactors.

Product reviews
Works great for what I need!
5
Anto
Avatar
3/25/2022 3:15 AM
I love this DC reactor so much. Bravo! It is easy to use and the quality is super great. At first, I thought it would be a piece of junk. Once I use it  and I knew that I  was wrong. It really deserves a high rating!
Was this review helpful? Yes No (0/0)
Perfect reactor for my inverter system
5
Maren
Avatar
7/15/2026 7:24 PM
I was looking for a way to improve my inverter system, and this reactor solved the problem. The current response is smoother, and the whole system feels more stable during operation.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

10 hp (7.5 kW) DC Reactor, Single Phase

ATO-DCR-10
$149.72
10 hp power DC reactor for reducing harmonic interference, single phase, DC output voltage 220V, 380V, 400V is available, other voltage can be customized, DC smoothing reactor for vfd, material aluminum or copper.