3/4 hp NEMA AC Induction Motor, Split Phase 115/230V, ODP/TEFC

$571.19
Cheap 3/4 hp split phase AC induction motor, 4 pole, 1725 rpm, 1.25 SF, ODP or TEFC enclosure type, foot mounted of mounting method, suitable operation at 60Hz 150/230V AC.
SKU: ATO-IM-RS344
*
Free Shipping
Delivery date: 6-12 days

56 frame split phase AC electric induction motor or asynchronous motor, 3/4 hp output power, 1725 rpm speed, NEMA design B, full load current 8.8 amps at 115V, 4.4 amps at 150/230V. Highly compact and rigid in order to deflect any deflection during operation.

3/4 hp Induction Motor Specification

BasicsModelATORS344D01ATORS344T01
EnclosureODPTEFC
TypeGeneral Purpose Asynchronous Motor
Item Weight25 Ibs
Motor Length12.7 inch
Frame56 Frame
DesignNEMA Design B
CertificationCE, UL
Motor MaterialRoll Steel
Technical ParametersService Factor1.25
Horsepower1/2 hp
Rated Frequency60 Hz
PhaseSplit Phase
Pole4 pole
Voltage115/230V AC
Full Load Amps8.8/4.4A
Speed1725 RPM
Efficiency73%
DutyContinuous
Isulation ClassClass F
Protection ClassIP54/ IP55
Mounting MethodFoot Mounted
EnvironmentAmbient temperature-15℃≤θ≤40℃
AltitudeAltitude should be lower than 1000 meters above sea level

3/4 hp Induction Motor Dimension

1/2 hp AC Single Phase Induction Motor Dimension

Unit: inch

Frame SizeABBAMax AMax BCDE2FHNN-WOPRSUMin VMin ESMin AA
565.62.756.54.211.43.52.4430.342.41.886.76.450.5170.1880.6251.51.411/2

NEMA AC Induction Motor Connection Diagram

Nema induction motor connection diagram

Details

3/4hp NEMA AC Induction Motor Details

Tips: Faults of AC Induction Motor
The faults of AC induction motor are generally divided into two parts: One part is the mechanical reason, such as the damaged bearing or fan blade. The other part is the electromagnetism fault. The two are correlated. For example, the bearing damage will probably cause motor overload or even short circuit. The damage of the fan blade enables the motor winding to have difficult heat dissipation, increased temperature and low insulation. There are many reasons for electromagnetism fault. For example, motor overload, short circuit or voltage shortage can cause motor damage, in which, short circuit is more dangerous. In addition to the above, the reasons causing motor fault still include the following reasons:

  1. Too high ambient temperature, poor dissipation condition.
  2. High starting current of the motor or too long starting time.
  3. Long-term low-speed operation of the motor.
  4. Frequent starting and braking and so on of the motor.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

Product reviews
This 3/4 hp AC induction motor works
5
Dennis Schultz
Avatar
10/11/2018 7:37 PM
Ordered this single phase induction motor to replace an old motor on a hay elevator. So far, no issues. It works as it should.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

56 frame split phase AC electric induction motor or asynchronous motor, 3/4 hp output power, 1725 rpm speed, NEMA design B, full load current 8.8 amps at 115V, 4.4 amps at 150/230V. Highly compact and rigid in order to deflect any deflection during operation.

3/4 hp Induction Motor Specification

BasicsModelATORS344D01ATORS344T01
EnclosureODPTEFC
TypeGeneral Purpose Asynchronous Motor
Item Weight25 Ibs
Motor Length12.7 inch
Frame56 Frame
DesignNEMA Design B
CertificationCE, UL
Motor MaterialRoll Steel
Technical ParametersService Factor1.25
Horsepower1/2 hp
Rated Frequency60 Hz
PhaseSplit Phase
Pole4 pole
Voltage115/230V AC
Full Load Amps8.8/4.4A
Speed1725 RPM
Efficiency73%
DutyContinuous
Isulation ClassClass F
Protection ClassIP54/ IP55
Mounting MethodFoot Mounted
EnvironmentAmbient temperature-15℃≤θ≤40℃
AltitudeAltitude should be lower than 1000 meters above sea level

3/4 hp Induction Motor Dimension

1/2 hp AC Single Phase Induction Motor Dimension

Unit: inch

Frame SizeABBAMax AMax BCDE2FHNN-WOPRSUMin VMin ESMin AA
565.62.756.54.211.43.52.4430.342.41.886.76.450.5170.1880.6251.51.411/2

NEMA AC Induction Motor Connection Diagram

Nema induction motor connection diagram

Details

3/4hp NEMA AC Induction Motor Details

Tips: Faults of AC Induction Motor
The faults of AC induction motor are generally divided into two parts: One part is the mechanical reason, such as the damaged bearing or fan blade. The other part is the electromagnetism fault. The two are correlated. For example, the bearing damage will probably cause motor overload or even short circuit. The damage of the fan blade enables the motor winding to have difficult heat dissipation, increased temperature and low insulation. There are many reasons for electromagnetism fault. For example, motor overload, short circuit or voltage shortage can cause motor damage, in which, short circuit is more dangerous. In addition to the above, the reasons causing motor fault still include the following reasons:

  1. Too high ambient temperature, poor dissipation condition.
  2. High starting current of the motor or too long starting time.
  3. Long-term low-speed operation of the motor.
  4. Frequent starting and braking and so on of the motor.
Product reviews
This 3/4 hp AC induction motor works
5
Dennis Schultz
Avatar
10/11/2018 7:37 PM
Ordered this single phase induction motor to replace an old motor on a hay elevator. So far, no issues. It works as it should.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews