2" DN50 Pneumatic Diaphragm Globe Shut-off Valve

$1,789.99
2 inch DN 50 pneumatic diaphragm shut-off valve with pneumatic actuator for sale, widely used in industrial fluid control. 304 stainless steel valve body material, rated stroke 12mm, nominal pressure PN16. Adopt pneumatic actuator, reliable operation, suitable for automation system.
SKU: ATO-PGV-DN50
*
Free Shipping
Delivery date: 6-12 days

Note: This globe valve cannot be used for drinking water.

High quality 2 inch pneumatic globe shut-off valve adopts advanced pneumatic technology to ensure precise control and long service life, single seated conical spool, soft seal + hard seal, max working pressure PN16, with high durability and stability, reliably meets all kinds of fluid pipeline needs.

Specification

ModelATO-810D-1S2A-4DK41-DN50
Pipe Diameter2" DN50
Nominal PressurePN16 MPa
Rated Flow Coefficient48 KV
Rated Stroke12 mm
Film Effective Area200 cm²
Allowable Pressure DifferencePositive Action: 1.33
Opposite Reaction: 1.77
Signal Pressure0 or 250
Allowable LeakageHard Seal: General: 10-4 × valve rated capacity; Tight type: single-seat: 1.2 × 10-7
Soft Seal: Class VI
Operating Temperature≤ 250℃
Connection MethodFlangeless
Medium of UseGas and Liquid
Valve Body Material304
Bonnet TypeStandard type (-17 ~ +250℃)
Cover TypeScrew compression type
Sealing MaterialV-shaped PTFE packing, reinforced PTFE packing, graphite braided packing, flexible graphite
Valve Core TypeSingle-seat spool
Flow CharacteristicsQuick opening characteristic
Included AccessoriesPneumatic diaphragm actuator, DC24V solenoid valve, limit switch, and air filter regulator.


Dimension (Unit: mm)

Pneumatic globe valve dimension

DNALHH1H4
5029025485.5185310


Application

Pneumatic globe valve application

Tips: 2" Pneumatic Globe Valve Troubleshooting

First, check if the air supply is normal, make sure the pneumatic actuator can get enough air pressure. If the air supply is normal, but the actuator does not respond, it may be an internal problem of the pneumatic actuator, and you need to check whether the piston, cylinder and seals of the actuator are intact.

Next, check to see if the connection between the body and bonnet of the 2-inch pneumatic globe valve is tight. If there is looseness or air leakage, you need to retighten the bolts or replace the sealing gasket.

Further, check that the spool is not contaminated or clogged. Contamination may cause the spool to move poorly or the valve may not close completely. Clean the spool and its surrounding parts to ensure that the spool can move freely.

Finally, check the control system to ensure proper signaling. Check that the pneumatic shutoff valve and associated sensors are working properly to rule out the possibility of a faulty control system. Effectively troubleshoot the 2 inch pneumatic globe valve to ensure that it is functioning properly. If the problem is still not solved, it is recommended to seek professional technical support.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Note: This globe valve cannot be used for drinking water.

High quality 2 inch pneumatic globe shut-off valve adopts advanced pneumatic technology to ensure precise control and long service life, single seated conical spool, soft seal + hard seal, max working pressure PN16, with high durability and stability, reliably meets all kinds of fluid pipeline needs.

Specification

ModelATO-810D-1S2A-4DK41-DN50
Pipe Diameter2" DN50
Nominal PressurePN16 MPa
Rated Flow Coefficient48 KV
Rated Stroke12 mm
Film Effective Area200 cm²
Allowable Pressure DifferencePositive Action: 1.33
Opposite Reaction: 1.77
Signal Pressure0 or 250
Allowable LeakageHard Seal: General: 10-4 × valve rated capacity; Tight type: single-seat: 1.2 × 10-7
Soft Seal: Class VI
Operating Temperature≤ 250℃
Connection MethodFlangeless
Medium of UseGas and Liquid
Valve Body Material304
Bonnet TypeStandard type (-17 ~ +250℃)
Cover TypeScrew compression type
Sealing MaterialV-shaped PTFE packing, reinforced PTFE packing, graphite braided packing, flexible graphite
Valve Core TypeSingle-seat spool
Flow CharacteristicsQuick opening characteristic
Included AccessoriesPneumatic diaphragm actuator, DC24V solenoid valve, limit switch, and air filter regulator.


Dimension (Unit: mm)

Pneumatic globe valve dimension

DNALHH1H4
5029025485.5185310


Application

Pneumatic globe valve application

Tips: 2" Pneumatic Globe Valve Troubleshooting

First, check if the air supply is normal, make sure the pneumatic actuator can get enough air pressure. If the air supply is normal, but the actuator does not respond, it may be an internal problem of the pneumatic actuator, and you need to check whether the piston, cylinder and seals of the actuator are intact.

Next, check to see if the connection between the body and bonnet of the 2-inch pneumatic globe valve is tight. If there is looseness or air leakage, you need to retighten the bolts or replace the sealing gasket.

Further, check that the spool is not contaminated or clogged. Contamination may cause the spool to move poorly or the valve may not close completely. Clean the spool and its surrounding parts to ensure that the spool can move freely.

Finally, check the control system to ensure proper signaling. Check that the pneumatic shutoff valve and associated sensors are working properly to rule out the possibility of a faulty control system. Effectively troubleshoot the 2 inch pneumatic globe valve to ensure that it is functioning properly. If the problem is still not solved, it is recommended to seek professional technical support.

Only registered users can write reviews