Use a 2 amp 2 pole miniature circuit breaker in a low voltage electrical network. ATO mini MCB breaker is more sensitive to overcurrent and a reliable way to protect conductors.
Double Pole MCB Breaker Information
- Rated Current: 2 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of poles: 2 poles
- 6 kA rated short-circuit breaking capacity
- Compliant with IEC standard
- C curve trip characteristic
- With overload protection and short circuit protection function
Technical Data
| Model | ATO-NB8-632PC02 | |
| Rated Current | 2A | |
| Rated Voltage | 230/400V | |
| Frequency | 50Hz | |
| Number of Poles | 2P | |
| Mechanical Life | 20000 Times | |
| Electrical Life | 10000 Times | |
| Rated Short-Circuit Breaking Capacity | 6000A | |
| Operating Short-Circuit Breaking Capacity | 6000A | |
| Rated Impulse Withstand Voltage (1.2/50) | 6kV | |
| Dielectric Test Voltage | 2000V (50Hz, 1 min) | |
| Heat & Humidity Resistance | 28 Cycles | |
| Vibration Resistance | No Obvious Vibration and Impact | |
| Terminal Block | Terminal Block Type | Pillar Terminal Block |
| Min. Terminal Size Acceptability | 1mm2 | |
| Max. Terminal Size Acceptability | 25mm2 | |
| Standard Connection Torque | 2 N.m | |
| Max. Tolerable Torque | 2.5 N.m | |
| Wire Insertion Depth | 13mm | |
| Reference Temperature | 30℃ | |
| Operating Temperature | -35℃~+70℃ | |
| Storage Temperature | 35℃~+85℃ | |
| Applicable Altitude | 2000m | |
| Tripping Mode | Thermal Magnetic Trip | |
| Electromagnetic Tripping Type | Type C (5In-10In) | |
| Shell Flame Retardant Grade | V0 | |
| Wire Entry Method | Both Upper and Lower | |
| Installation Method | TH35-7.5 Standard Rail | |
| Protection Level | Direct Installation | IP20B |
| Installed in the Distribution Box | IP40B | |
Double Pole MCB Breaker Dimensions (Unit: mm)

Details

Tips: The main components of the miniature circuit breaker
A miniature circuit breaker (MCB) is a crucial safety device in electrical circuits, designed to automatically disconnect the circuit in the event of overload or short circuit. Its main components include:
- Frame: The outer casing that houses all the components, made from insulating materials to prevent electrical contact.
- Contact System: Includes moving and fixed contacts that open and close the circuit. When a fault occurs, the contacts separate to interrupt the flow of electricity.
- Trip Mechanism: This includes two types—thermal and magnetic. The thermal trip uses a bimetallic strip that bends with heat caused by an overload, while the magnetic trip uses an electromagnet to react to the sudden surge of current during a short circuit.
- Arc Chute: A device used to quench the electrical arc formed when the contacts separate, preventing the arc from damaging the micro circuit breaker and ensuring safe operation.
- Terminal Block: The points where the mini MCB connects to the incoming and outgoing electrical circuits.