1000A Three Phase Plating Rectifier, 12V/18V/24V

$3,849.23
1000A three phase IGBT rectifier for hard chrome electroplating process, air cooling mode, 380V/ 400V/ 480V AC input, 0-12V/ 0-18V/ 0-24V DC output, current and output voltage can be adjusted. It has many protection functions against phase loss, over-voltage, under-voltage, short circuit, over current and overheating.
SKU: ATO-HI-1K
*
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

Factory wholesale high efficiency industrial plating machine combined with remote controller box, 1000 amps high current, customized wide range 220-1000V AC three phase input voltage and 8-500V DC output voltage. Reliable quality and competitive price rectifier switching power supply will definitely satisfy your requirements.

Application: This kind of plating rectifier is mainly used in brush plating process, suitable for repairing plated work pieces with defects, depositing different metal patterns on metal surfaces and electrolysis degreasing and plating process etc.

Specification

ModelATO-HI-1000
Input Voltage (Optional)*Three phase AC 380V/ 400V/ 415V/ 440V/ 460V/ 480V (220-1000V voltages are customizable)
Input Frequency50Hz/60Hz
Output Current0-1000A (continuously adjustable by 1A)
Output Voltage (Optional)*DC 0-12V/ 0-18V/ 0-24V/ 0-36V/ 0-48V (8-500V voltages are customizable)
Note: Output voltage is adjustable by 0.1V.
Output Frequency15kHz
Output Current Stability≤1%
Output Voltage Stability≤1%
Efficiency≥92%
Power Factor≥0.9
Operation ModeRemote control or manual control
ModuleIGBT module
Cooling MethodAir cooling
Start-up Postponing Time≤10s
Limiting Current ValueIo±5A (Io is the rated current)
Limiting Voltage ValueVo±5A (Vo is the rated current)
Signal Interface (Optional)*RS485, PLC 0-10V, 4-20mA
RS485 Interface FunctionCan be used to monitor parameters, control voltage & current values, and remotely start/stop the rectifier.
Control Box (Included)Can adjust the output voltage, current and time, with standard 0-30m remote connection cable. Longer cables can be customized!
PLC Touch Screen (Optional)*Plating rectifier connects with PLC touch screen by RS485 interface to display/adjust the voltage, current and time.
Modulation ModePWM control
Complete Protection FunctionsOver current, over voltage, over heat, short circuit, phase lack, input undercurrent protection, over temperature, diode defect...
Protection GradeIP20
Ambient Temperature-10℃-50℃
Relative Humidity≤80%
Size650*520*260mm
Net Weight90kg
CertificationCE, ISO
Warranty12 months
Packing Included1 x Three Phase Plating Rectifier
1 x Remote Control Box
1 x 0-5m Cable


Plating Rectifier Main Technical Features

  • Operation mode: Remote control or manual control for optional.
  • Output control mode: One-way pulse and two-way pulse output control for optional.
  • Constant output control mode: Constant current and constant voltage control modes can be selected.
  • Soft start time: Soft start working time can be set in the range of 0-200s.
  • High control accuracy: Control accuracy ≤ ± 1%.
  • Rectification mode: IGBT inverter soft switch rectification, PWM pulse step modulation, IGBT chopper control mode.
  • Pulse pacing frequency range: 1000-8000Hz.
  • Man-machine operation interface: PLC color touch screen.
  • Main controller: DSP microcomputer digital trigger control, PWM pulse width adjustment control, pulse phase shift resolution ≤1μs.
  • Main protection functions: AC power phase loss, overvoltage, undervoltage, fast fuse blowing alarm and circuit breaker protection; output overcurrent, current limit protection, output short circuit, instantaneous overload protection; IGBT switch module, fast rectifier components, switching rectifier transformer, busbar copper bus overtemperature and overheating, fan overheating or water pressure is too high/low, blocking PWM trigger pulse protection.
  • Communication method: CAN bus, PROFIBUS, ETHERNET industrial Ethernet, RS485, and RS232 optical fiber communication can be configured according to customer needs to achieve remote group control or monitoring.
  • With 1-5 stages of constant current slow rise and slow down stage number control, each stage oxidation current and oxidation time can be set separately.
  • Real-time recording of multiple process parameters and real-time curves such as forward and reverse current / voltage, pulse current/voltage amplitude, pulse duty cycle, pulse frequency, oxidation time, bath temperature, etc.
  • Remote operation control box: The remote operation control box can be configured according to the customer's site conditions, the plating rectifier machine and the remote control box are separated to prevent, the field operation is more convenient, and the rectifier's corrosion protection is significantly enhanced.
  • 5 sets of process parameters can be stored or recalled to shorten the processing programming time.
  • Can be connected to the computer through the RS485 communication interface, or stored in the U disk and transferred to the computer, which is convenient for the customer to save the file and analyze the product process quality of the oxidized workpiece.
  • Workpiece coating quality: Compactness, smoothness and corrosion resistance are significantly better than the ordinary plating process.

Tips: The power indicator on the plating rectifier doesn't work. What should I do?

The power switch indicator light is set in the electroplating rectifier equipment for the convenience of detecting power failure. When it is normally energized, it will give off normal light. When it is no longer luminous, it is obvious that there is a fault in the power supply. The reasons for the fault are as follows:

  1. The power cord is not plugged in properly. It may be the power socket is not strong, or the power cord and socket are damaged. At this time should be plugged into the socket, and connected to the power supply, usable pen detection is a problem.
  2. The main switching power supply connected to the rectifier is not connected. This may be caused by the staff forgetting for a while, so please turn on the main power supply.
  3. In addition, the lack of phase in the three-phase power supply will also cause the plating rectifier to fail to supply power normally and should be checked and repaired in time.
Product reviews
Appearance of 1000A three phase plating rectifier
5
Elemenoh
Avatar
7/21/2021 7:49 PM
How is your plating rectifier terminals looks like?
Was this review helpful? Yes No (0/0)
ATO Responded
Its hard wire "free terminals".
Can this rectifier replace my old ones?
5
Miser
Avatar
5/25/2022 12:37 AM
I am looking for the rectifiers to replace the old ones that we are currently using. The input is 230/ 240V, 22A, 4,8kVA, 1~  50/60 Hz. Output is 4V, 300A, 1.2 kVA. Is this 1000A 3-phase rectifier can replace my old ones?
Was this review helpful? Yes No (0/0)
ATO Responded
1.Is this single-phase voltage or three-phase for input is 230/ 240V?
2.We can provide this unit ATO-HI-300. Input voltage: 230/ 240VAC (1 phase); Output: 4 VDC, 300 AMP.
3.What field will this machine is used in?
Can I use this rectifier to plate Aluminum?
5
arvin
Avatar
6/14/2023 2:49 AM
Can I use this rectifier to plate Aluminum?
Was this review helpful? Yes No (0/0)
ATO Responded
Aluminum alloy is anodized. We have an oxidation power supply, do you need ordinary anodizing or hard anodizing?
What rectifier output current and voltage do you need?
Great rectifier for the price
5
Jake Goering
Avatar
3/25/2024 8:28 PM
The 1000A three phase plating rectifier has been a game-changer for our industrial plating operations. Its robust design and consistent performance under heavy loads have significantly improved our productivity and process stability. The rectifier's high current capacity allows for faster plating times, which in turn has increased our throughput. Its efficiency in power conversion has also led to noticeable energy savings, reducing our operational costs. The user interface is intuitive, making system monitoring and adjustments hassle-free.
Was this review helpful? Yes No (0/0)
Looking for a rectifier
4
Searle
Avatar
8/29/2025 12:22 AM
I'm looking for a quote on a rectifier. Input voltage: 110V or 230V, both work. Cooling method: air, output voltage: 12V, output current: 1000A. Any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend our 1000A three-phase electroplating rectifier, 12V, SKU: ATO-HI-1K. We can customize single-phase 230V input voltage. Please also let us know the rectifier's control signal, including whether it has an LC touchscreen control, so we can provide a quote.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Factory wholesale high efficiency industrial plating machine combined with remote controller box, 1000 amps high current, customized wide range 220-1000V AC three phase input voltage and 8-500V DC output voltage. Reliable quality and competitive price rectifier switching power supply will definitely satisfy your requirements.

Application: This kind of plating rectifier is mainly used in brush plating process, suitable for repairing plated work pieces with defects, depositing different metal patterns on metal surfaces and electrolysis degreasing and plating process etc.

Specification

ModelATO-HI-1000
Input Voltage (Optional)*Three phase AC 380V/ 400V/ 415V/ 440V/ 460V/ 480V (220-1000V voltages are customizable)
Input Frequency50Hz/60Hz
Output Current0-1000A (continuously adjustable by 1A)
Output Voltage (Optional)*DC 0-12V/ 0-18V/ 0-24V/ 0-36V/ 0-48V (8-500V voltages are customizable)
Note: Output voltage is adjustable by 0.1V.
Output Frequency15kHz
Output Current Stability≤1%
Output Voltage Stability≤1%
Efficiency≥92%
Power Factor≥0.9
Operation ModeRemote control or manual control
ModuleIGBT module
Cooling MethodAir cooling
Start-up Postponing Time≤10s
Limiting Current ValueIo±5A (Io is the rated current)
Limiting Voltage ValueVo±5A (Vo is the rated current)
Signal Interface (Optional)*RS485, PLC 0-10V, 4-20mA
RS485 Interface FunctionCan be used to monitor parameters, control voltage & current values, and remotely start/stop the rectifier.
Control Box (Included)Can adjust the output voltage, current and time, with standard 0-30m remote connection cable. Longer cables can be customized!
PLC Touch Screen (Optional)*Plating rectifier connects with PLC touch screen by RS485 interface to display/adjust the voltage, current and time.
Modulation ModePWM control
Complete Protection FunctionsOver current, over voltage, over heat, short circuit, phase lack, input undercurrent protection, over temperature, diode defect...
Protection GradeIP20
Ambient Temperature-10℃-50℃
Relative Humidity≤80%
Size650*520*260mm
Net Weight90kg
CertificationCE, ISO
Warranty12 months
Packing Included1 x Three Phase Plating Rectifier
1 x Remote Control Box
1 x 0-5m Cable


Plating Rectifier Main Technical Features

  • Operation mode: Remote control or manual control for optional.
  • Output control mode: One-way pulse and two-way pulse output control for optional.
  • Constant output control mode: Constant current and constant voltage control modes can be selected.
  • Soft start time: Soft start working time can be set in the range of 0-200s.
  • High control accuracy: Control accuracy ≤ ± 1%.
  • Rectification mode: IGBT inverter soft switch rectification, PWM pulse step modulation, IGBT chopper control mode.
  • Pulse pacing frequency range: 1000-8000Hz.
  • Man-machine operation interface: PLC color touch screen.
  • Main controller: DSP microcomputer digital trigger control, PWM pulse width adjustment control, pulse phase shift resolution ≤1μs.
  • Main protection functions: AC power phase loss, overvoltage, undervoltage, fast fuse blowing alarm and circuit breaker protection; output overcurrent, current limit protection, output short circuit, instantaneous overload protection; IGBT switch module, fast rectifier components, switching rectifier transformer, busbar copper bus overtemperature and overheating, fan overheating or water pressure is too high/low, blocking PWM trigger pulse protection.
  • Communication method: CAN bus, PROFIBUS, ETHERNET industrial Ethernet, RS485, and RS232 optical fiber communication can be configured according to customer needs to achieve remote group control or monitoring.
  • With 1-5 stages of constant current slow rise and slow down stage number control, each stage oxidation current and oxidation time can be set separately.
  • Real-time recording of multiple process parameters and real-time curves such as forward and reverse current / voltage, pulse current/voltage amplitude, pulse duty cycle, pulse frequency, oxidation time, bath temperature, etc.
  • Remote operation control box: The remote operation control box can be configured according to the customer's site conditions, the plating rectifier machine and the remote control box are separated to prevent, the field operation is more convenient, and the rectifier's corrosion protection is significantly enhanced.
  • 5 sets of process parameters can be stored or recalled to shorten the processing programming time.
  • Can be connected to the computer through the RS485 communication interface, or stored in the U disk and transferred to the computer, which is convenient for the customer to save the file and analyze the product process quality of the oxidized workpiece.
  • Workpiece coating quality: Compactness, smoothness and corrosion resistance are significantly better than the ordinary plating process.

Tips: The power indicator on the plating rectifier doesn't work. What should I do?

The power switch indicator light is set in the electroplating rectifier equipment for the convenience of detecting power failure. When it is normally energized, it will give off normal light. When it is no longer luminous, it is obvious that there is a fault in the power supply. The reasons for the fault are as follows:

  1. The power cord is not plugged in properly. It may be the power socket is not strong, or the power cord and socket are damaged. At this time should be plugged into the socket, and connected to the power supply, usable pen detection is a problem.
  2. The main switching power supply connected to the rectifier is not connected. This may be caused by the staff forgetting for a while, so please turn on the main power supply.
  3. In addition, the lack of phase in the three-phase power supply will also cause the plating rectifier to fail to supply power normally and should be checked and repaired in time.
Product reviews
Appearance of 1000A three phase plating rectifier
5
Elemenoh
Avatar
7/21/2021 7:49 PM
How is your plating rectifier terminals looks like?
Was this review helpful? Yes No (0/0)
ATO Responded
Its hard wire "free terminals".
Can this rectifier replace my old ones?
5
Miser
Avatar
5/25/2022 12:37 AM
I am looking for the rectifiers to replace the old ones that we are currently using. The input is 230/ 240V, 22A, 4,8kVA, 1~  50/60 Hz. Output is 4V, 300A, 1.2 kVA. Is this 1000A 3-phase rectifier can replace my old ones?
Was this review helpful? Yes No (0/0)
ATO Responded
1.Is this single-phase voltage or three-phase for input is 230/ 240V?
2.We can provide this unit ATO-HI-300. Input voltage: 230/ 240VAC (1 phase); Output: 4 VDC, 300 AMP.
3.What field will this machine is used in?
Can I use this rectifier to plate Aluminum?
5
arvin
Avatar
6/14/2023 2:49 AM
Can I use this rectifier to plate Aluminum?
Was this review helpful? Yes No (0/0)
ATO Responded
Aluminum alloy is anodized. We have an oxidation power supply, do you need ordinary anodizing or hard anodizing?
What rectifier output current and voltage do you need?
Great rectifier for the price
5
Jake Goering
Avatar
3/25/2024 8:28 PM
The 1000A three phase plating rectifier has been a game-changer for our industrial plating operations. Its robust design and consistent performance under heavy loads have significantly improved our productivity and process stability. The rectifier's high current capacity allows for faster plating times, which in turn has increased our throughput. Its efficiency in power conversion has also led to noticeable energy savings, reducing our operational costs. The user interface is intuitive, making system monitoring and adjustments hassle-free.
Was this review helpful? Yes No (0/0)
Looking for a rectifier
4
Searle
Avatar
8/29/2025 12:22 AM
I'm looking for a quote on a rectifier. Input voltage: 110V or 230V, both work. Cooling method: air, output voltage: 12V, output current: 1000A. Any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend our 1000A three-phase electroplating rectifier, 12V, SKU: ATO-HI-1K. We can customize single-phase 230V input voltage. Please also let us know the rectifier's control signal, including whether it has an LC touchscreen control, so we can provide a quote.
Only registered users can write reviews
Customers who bought this item also bought

500A Three Phase Plating Rectifier, 400V AC to 20V DC

ATO-HI-500
$2,768.25
Adjustable 0-500A electroplating rectifier switch power supply adopts PWM control circuit and high reliability IGBT module, input voltage of three phase 380V/ 480V AC (220-1000V can be customized), output voltage of 20V/ 24V DC (8-500V can be customized), forced air-cooling type, with complete protection functions.