Portable Oxygen (O2) Gas Detector, 0 to 30% Vol

$479.22
Portable oxygen detector, ideal for monitoring O2 gas concentration in the range of 0 to 30% Vol or 0 to 100% Vol, with sound, light and vibrating alarm, light and compact, easy to setting and operation, long working time with large capacity battery, high accuracy and low price.
SKU: GD200-O2
*
*
*
Free Shipping
Delivery date: 6-12 days

Portable O2 gas detector is used to monitor 0 to 30% Vol or 100% Vol oxygen concetration, widely used for laboratories, research institutions, vehicle battery industry, confined space and so on.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-O2
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasOxygen (O2)
Range (Optional)*0 to 25% VOL, 0 to 30% VOL, 0 to 100% VOL
Resolution0.01% VOL
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note 1:

  • If you require an O2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Oxygen (O2) Gas Detector

Tips: How to Choose the Measuring Range of Oxygen Gas Detector?

Oxygen concentration in the air is 20.9%VOL. Checking whether the oxygen content is up to the standard or not, we generally select an oxygen (O2) detector with a range of 0~20%VOL or 0~30%VOL. Such a measuring range can meet most demands, and it’s also the most common range. ATO portable oxygen detector is avaliable for 0 to measuring range of 30% Vol to meet the most common requirements.

In some cases, the oxygen concentration will also be tested, such as testing the purity of oxygen in oxygen bottle, then an oxygen detector with a range of 0~100%VOL is chosen. The precision can be customized, which is generally 0.1%VOL and 0.01%VOL. As for the special case that oxygen concentration is far below the normal value, such as the anaerobic incubator and smoke, the oxygen concentration is quite low, thus a range of 0~5%VOL is generally selected.

Basic Settings of Portable Gas Detector

This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

Calibration of Portable Gas Detector

This video will show how to calibrate the ATO portable gas detectors.

Concentration Detection of Pesticides Gas

Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

How to Detect Hydrogen Sulfide Concentration in the Toilet

Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

How much C2H4 (ethylene) do ripe bananas and apples produce?

We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

How Does a Portable Detector Work?

This video explains how a portable detector works and uses it to measure the air around you.

Portable Single Gas Detector Parameter Settings

In this video, we show you the menu settings of the ATO portable detector. Five button operation makes it very simple to control and activate functions. This device provides two alarm types, high alarm point and low alarm point, which can be adjusted as needed. The speed of the pump is also allowed to be adjusted. Calibration options include zero calibration and span calibration, both of which should be performed by qualified professionals under strict operating conditions using necessary accessories and standard gases.

How to Calibrate a Portable Gas Detector?

This video shows how to calibrate a portable gas detector. The ATO portable gas detector is lithium battery powered, has data logging capabilities and is available with a calibration kit.

Gas Detector Detection Range Setting

This video demonstrates the detection range setting of a portable gas detector.

Product reviews
We are looking for a gas leak detector for O2, N2 and CO2.
5
Tarek
Avatar
8/25/2020 7:11 PM
We are looking for a gas leak detector for O2, N2 and CO2. It is used for detecting leaks from piping in the incubators. Do you have any compatible products?
Was this review helpful? Yes No (0/0)
ATO Responded
Our gas detector can only measure O2 and CO2 at the same time, but cannot measure N2 and O2 at the same time, so you need to purchase a N2 gas detector separately.
Satisfied with this oxygen gas detector
5
Alob
Avatar
7/20/2022 3:20 AM
I have been using this portable oxygen gas detector for three months. During this period of time, the oxygen gas detector has been working very well, and my colleagues are very satisfied with it.
Was this review helpful? Yes No (0/0)
Would your sensor be suitable for this kind of setup?
5
rayparker
Avatar
3/6/2023 1:23 AM
As suggested on https://www.ato.com/fixed-oxygen-o2-gas-detector, I’m emailing to request information on using this sensor in a pressure chamber working at about 1.2 bars. The chamber will have a heated mould and a constant 170 liter/h N2 supply, and we intend to measure the remaining oxygen concentration.

One option would be to connect the sensor directly to the box, but as the temperature inside is well over the working temperature specified, we were thinking to let the overflow run via a cooling system and measure the O2 concentration of the outgoing gas mixture at the end of this line.

Would your sensor be suitable for this kind of setup, or do you have a suggestion on how to implement the sensor some other way?

Thanks in advance for the information!
Was this review helpful? Yes No (0/0)
ATO Responded
We also need to confirm the following information:
1. Pressure: Our instrument is 1bar±10%, but your pressure chamber working at about 1.2 bars, can you lower the pressure a little;
2. Temperature: The operating temperature range of our instruments is -20°C~50°C;
3. Humidity: best controlled below 60%RH;
4. Flow rate: 2.8L/min is a bit high, can you please reduce it to 1.5L/min;
5. What is the approximate oxygen concentration you need to detect? Our oxygen detector has a range of 0-25%VOL and a resolution of 0.01%VOL. If it is to measure trace oxygen at PPM level, our products can Not detect it.
Please recommend
4
Karike
Avatar
4/21/2025 8:22 PM
We currently have an FTIR system in our lab that detects a variety of gases, but our primary goal is to measure oxygen concentrations. Any recommendations? Carbon monoxide (CO) concentrations are expected to be between 0-3000ppm, while hydrogen (H) concentrations may exceed 20,000ppm. Carbon dioxide (CO2) concentrations are expected to be in a similar range.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, CO and H2 concentrations are higher and we currently do not have any available models to recommend. None of the anti-interference sensors we offer can achieve such a large range.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Portable O2 gas detector is used to monitor 0 to 30% Vol or 100% Vol oxygen concetration, widely used for laboratories, research institutions, vehicle battery industry, confined space and so on.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-O2
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasOxygen (O2)
Range (Optional)*0 to 25% VOL, 0 to 30% VOL, 0 to 100% VOL
Resolution0.01% VOL
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note 1:

  • If you require an O2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Oxygen (O2) Gas Detector

Tips: How to Choose the Measuring Range of Oxygen Gas Detector?

Oxygen concentration in the air is 20.9%VOL. Checking whether the oxygen content is up to the standard or not, we generally select an oxygen (O2) detector with a range of 0~20%VOL or 0~30%VOL. Such a measuring range can meet most demands, and it’s also the most common range. ATO portable oxygen detector is avaliable for 0 to measuring range of 30% Vol to meet the most common requirements.

In some cases, the oxygen concentration will also be tested, such as testing the purity of oxygen in oxygen bottle, then an oxygen detector with a range of 0~100%VOL is chosen. The precision can be customized, which is generally 0.1%VOL and 0.01%VOL. As for the special case that oxygen concentration is far below the normal value, such as the anaerobic incubator and smoke, the oxygen concentration is quite low, thus a range of 0~5%VOL is generally selected.

Product reviews
We are looking for a gas leak detector for O2, N2 and CO2.
5
Tarek
Avatar
8/25/2020 7:11 PM
We are looking for a gas leak detector for O2, N2 and CO2. It is used for detecting leaks from piping in the incubators. Do you have any compatible products?
Was this review helpful? Yes No (0/0)
ATO Responded
Our gas detector can only measure O2 and CO2 at the same time, but cannot measure N2 and O2 at the same time, so you need to purchase a N2 gas detector separately.
Satisfied with this oxygen gas detector
5
Alob
Avatar
7/20/2022 3:20 AM
I have been using this portable oxygen gas detector for three months. During this period of time, the oxygen gas detector has been working very well, and my colleagues are very satisfied with it.
Was this review helpful? Yes No (0/0)
Would your sensor be suitable for this kind of setup?
5
rayparker
Avatar
3/6/2023 1:23 AM
As suggested on https://www.ato.com/fixed-oxygen-o2-gas-detector, I’m emailing to request information on using this sensor in a pressure chamber working at about 1.2 bars. The chamber will have a heated mould and a constant 170 liter/h N2 supply, and we intend to measure the remaining oxygen concentration.

One option would be to connect the sensor directly to the box, but as the temperature inside is well over the working temperature specified, we were thinking to let the overflow run via a cooling system and measure the O2 concentration of the outgoing gas mixture at the end of this line.

Would your sensor be suitable for this kind of setup, or do you have a suggestion on how to implement the sensor some other way?

Thanks in advance for the information!
Was this review helpful? Yes No (0/0)
ATO Responded
We also need to confirm the following information:
1. Pressure: Our instrument is 1bar±10%, but your pressure chamber working at about 1.2 bars, can you lower the pressure a little;
2. Temperature: The operating temperature range of our instruments is -20°C~50°C;
3. Humidity: best controlled below 60%RH;
4. Flow rate: 2.8L/min is a bit high, can you please reduce it to 1.5L/min;
5. What is the approximate oxygen concentration you need to detect? Our oxygen detector has a range of 0-25%VOL and a resolution of 0.01%VOL. If it is to measure trace oxygen at PPM level, our products can Not detect it.
Please recommend
4
Karike
Avatar
4/21/2025 8:22 PM
We currently have an FTIR system in our lab that detects a variety of gases, but our primary goal is to measure oxygen concentrations. Any recommendations? Carbon monoxide (CO) concentrations are expected to be between 0-3000ppm, while hydrogen (H) concentrations may exceed 20,000ppm. Carbon dioxide (CO2) concentrations are expected to be in a similar range.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, CO and H2 concentrations are higher and we currently do not have any available models to recommend. None of the anti-interference sensors we offer can achieve such a large range.
Only registered users can write reviews
Customers who bought this item also bought

Portable Hydrogen (H2) Gas Detector, 0 to 500/1000/2000 ppm

GD200-H2
$784.62
Portable hydrogen (H2) gas detector draws the gas sample by a micro pump, with high accuracy and reliability, measurement ranging from 0 to 500ppm, 1000ppm, 2000ppm, 5000ppm for your choice. Real-time LCD display, audible, visual & vibrating alarm, durable and compact design, easy to carry and operate. High precision H2 detector with measuring range 0-10ppm (0.001ppm) is also available.

Fixed Oxygen (O2) Gas Detector, 0 to 25% / 30% Vol

GD300-O2
$434.77
Fixed gas detector for detecting oxygen concentration. Measuring range 0~25% or 0~30% for selection, output signal 4-20mA and RS485, high accuracy 3% F.S. O2 gas detector has sound and light alarm, real-time display, remote control, small size, lightweight, low price.

Custom Order

ATO-CUSTOM
Pay for custom orders, or extra amount of existing orders.
Indicate the item specification you pay for, and specify PI / PO number if you have.

Portable Carbon Dioxide (CO2) Infrared Gas Detector, 0 to 2000/5000/10000 ppm

GD200-CO2
$969.23
Portable carbon dioxide (CO2) infrared detector adopts high accuracy sensor, measuring range available with 0-2000ppm, 0-5000ppm, 0-10000ppm, or 0-10%VOL, 0-20%VOL, 0 to 100% VOL, with LCD display, audible, visual & vibrating alarm, compact size, easy to carry and operate.

Portable Nitrogen (N2) Gas Detector, 0 to 100% Vol

GD200-N2
$891.38