High Temperature Limit Switch with Roller Lever

$148.15
High temperature limit switch adopts one roller lever with a radius of 38mm and fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material, can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Customizable voltage is DC 0-220V and AC 0-480V. Roller lever limit switch has automatic reset function. It is usually used for the machinery operating at a low speed.
SKU: ATO-HTLS-RL
Availability: In stock
Free Shipping
Delivery date: 2-3 days

High temperature limit switch has roller lever R38, contact type 1NO + 1NC and rated current/voltage 5A/220VAC. It has an IP66 protection rating, is highly dust and water resistant, and can operate reliably in harsh environments such as high-temperature industrial processes and outdoor installations.

Specification

ModelATO-HTLS-XWKA
Weight258g
Radius of roller lever38mm
Rated voltage220VAC (Customizable rated voltage is shown in the reference table below.)
Rated current5A (Customizable rated current is shown in the reference table below.)
Contact type1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4)
Operating speed1mm/s~2m/s
Operating frequencyMachinery: 120 times/minute
Electric: 30 times/minute
Contact resistance<15MΩ, initial stage
Insulation resistance>100MΩ (<500VDC)
Withstand voltageBetween no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute
Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute
Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute
VibrationMisoperation endurance: 10~55Hz, 1.5mm, double-amplitude
ImpactMechanical endurance: >1000m/s2 (>100G)
Misoperation endurance: >300m/s2 (>30G)
Shell materialCast aluminum alloy
Temperature-10~+350℃ (14~622℉)
Humidity<95%RH
Working lifeMachinery: >15million times
Electric: >0.5million times
Protection classIP66


Reference table for customizable rated voltage and rated current

Rated voltageRated current (A)
Non-inductive loadInductive load
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125VAC1031.51052
250VAC521531.0
480VAC31.50.831.50.8
600VAC110.51.510.5
8VDC1063106
14VDC1063106
30VDC64364
125VDC0.80.20.20.80.2
250VDC0.40.10.10.40.1

Note:

  1. Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
  2. The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.

Dimension (unit: mm)

High temperature limit switch with roller lever dimension

Tips: Limit switch structure

In order to adapt to high mechanical strength and harsh environment, the limit switch is assembled and sealed in a metal or resin housing to protect the built-in micro switch from external force, water, oil, gas and dust.

  1. Built-in switch
    The built-in switch adopts a snap-action mechanism. Operating plunger withstanding external force or action, the movable contact is moved from the lower normally closed (NC) contact to the upper normally open (NO) contact. A contact type that does not have a common (COM) pin and has a set of NO pins (a contact) and NC pins (b contact) is called a 1a1b contact type. General limit switches are used in this way. In addition, there is a 1c contact type limit switch composed of three pins of NO, NC and COM, which can be connected to the pins of the built-in switch with external connection wires directly.
  2. Switch box
    Used to enclose and protect built-in switches, made of metal or resin with excellent mechanical strength. There is a conduit port in the lower part of the switch box for installing a special connector. It is used to fix the external connection line and seal and protect the internal mechanism.
  3. Actuator
    External force or motion is transmitted to the built-in switch via the internal plunger. The movable part connecting the external actuator and the internal mechanism is sealed with a ring or a seal, and the built-in switch is enclosed therein. Typical actuator shapes are lever type, plunger type, spring type, etc., which can be used according to different purposes.
  4. Switch housing cover
    On the pins of the built-in switch of the limit switch, after the external connection wires are laid out, the switch housing cover should be installed. Seal the chimerical part of the switch box and housing cover with a rubber seal.

VFD Emergency Stop with Limit Switches

In this video, you will learn about the setup and operation of emergency stopping a motor by using limit switches and a variable frequency drive (VFD). By combining the limit switches of the emergency stop function with the VFD GK3000, a strong safety measure can be established that can quickly stop the motor operation in an emergency.

Automatic Material Trolley Control with Limit Switch

In this video, the method of applying limit switches to automatic material trolley control is demonstrated.

Roller Limit Switch NO NC Contact Wiring and Detection

In this video, the roller limit switch NO NC contact wiring and detection operation are shown.

Product reviews
The information you sent was good.
5
Estrada
Avatar
12/29/2021 8:05 PM
The information you sent was good. All set, I’ve sent the info to the building owner who will actually be placing the order this spring.
Was this review helpful? Yes No (0/0)
Head rotation angle
5
Morian
Avatar
8/18/2025 8:20 PM
Hello, can the head of this switch be rotated 90 degrees?
Was this review helpful? Yes No (0/0)
ATO Responded
The head of this switch can be rotated 90 degrees.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High temperature limit switch has roller lever R38, contact type 1NO + 1NC and rated current/voltage 5A/220VAC. It has an IP66 protection rating, is highly dust and water resistant, and can operate reliably in harsh environments such as high-temperature industrial processes and outdoor installations.

Specification

ModelATO-HTLS-XWKA
Weight258g
Radius of roller lever38mm
Rated voltage220VAC (Customizable rated voltage is shown in the reference table below.)
Rated current5A (Customizable rated current is shown in the reference table below.)
Contact type1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4)
Operating speed1mm/s~2m/s
Operating frequencyMachinery: 120 times/minute
Electric: 30 times/minute
Contact resistance<15MΩ, initial stage
Insulation resistance>100MΩ (<500VDC)
Withstand voltageBetween no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute
Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute
Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute
VibrationMisoperation endurance: 10~55Hz, 1.5mm, double-amplitude
ImpactMechanical endurance: >1000m/s2 (>100G)
Misoperation endurance: >300m/s2 (>30G)
Shell materialCast aluminum alloy
Temperature-10~+350℃ (14~622℉)
Humidity<95%RH
Working lifeMachinery: >15million times
Electric: >0.5million times
Protection classIP66


Reference table for customizable rated voltage and rated current

Rated voltageRated current (A)
Non-inductive loadInductive load
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125VAC1031.51052
250VAC521531.0
480VAC31.50.831.50.8
600VAC110.51.510.5
8VDC1063106
14VDC1063106
30VDC64364
125VDC0.80.20.20.80.2
250VDC0.40.10.10.40.1

Note:

  1. Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
  2. The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.

Dimension (unit: mm)

High temperature limit switch with roller lever dimension

Tips: Limit switch structure

In order to adapt to high mechanical strength and harsh environment, the limit switch is assembled and sealed in a metal or resin housing to protect the built-in micro switch from external force, water, oil, gas and dust.

  1. Built-in switch
    The built-in switch adopts a snap-action mechanism. Operating plunger withstanding external force or action, the movable contact is moved from the lower normally closed (NC) contact to the upper normally open (NO) contact. A contact type that does not have a common (COM) pin and has a set of NO pins (a contact) and NC pins (b contact) is called a 1a1b contact type. General limit switches are used in this way. In addition, there is a 1c contact type limit switch composed of three pins of NO, NC and COM, which can be connected to the pins of the built-in switch with external connection wires directly.
  2. Switch box
    Used to enclose and protect built-in switches, made of metal or resin with excellent mechanical strength. There is a conduit port in the lower part of the switch box for installing a special connector. It is used to fix the external connection line and seal and protect the internal mechanism.
  3. Actuator
    External force or motion is transmitted to the built-in switch via the internal plunger. The movable part connecting the external actuator and the internal mechanism is sealed with a ring or a seal, and the built-in switch is enclosed therein. Typical actuator shapes are lever type, plunger type, spring type, etc., which can be used according to different purposes.
  4. Switch housing cover
    On the pins of the built-in switch of the limit switch, after the external connection wires are laid out, the switch housing cover should be installed. Seal the chimerical part of the switch box and housing cover with a rubber seal.
Product reviews
The information you sent was good.
5
Estrada
Avatar
12/29/2021 8:05 PM
The information you sent was good. All set, I’ve sent the info to the building owner who will actually be placing the order this spring.
Was this review helpful? Yes No (0/0)
Head rotation angle
5
Morian
Avatar
8/18/2025 8:20 PM
Hello, can the head of this switch be rotated 90 degrees?
Was this review helpful? Yes No (0/0)
ATO Responded
The head of this switch can be rotated 90 degrees.
Only registered users can write reviews
Customers who bought this item also bought

High Temperature Limit Switch with Adjustable Roller Lever

ATO-HTLS-ARL
$148.15
High temperature limit switch adopts fully enclosed 1NO + 1NC contact switches, can be used in the environment temperature 350℃ (622℉). Its roller lever has the adjustable radius of 25-89mm to meet the needs of more occasions. Adjustable roller lever limit switch also has automatic reset function. The default rated current and voltage is 5A/220VAC, and other values (AC 120V/380V, DC 12V/24V/48V)can be customizable.

High Temperature Limit Switch with Roller Plunger

ATO-HTLS-RP
$148.15
There are two types of roller plunger limit switch, the roller direction of the one is parallel to the mounting surface, and the other is perpendicular to the mounting surface. Roller plunger has automatic reset function. It is also high temperature limit switch with the fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material. It can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Other values are customizable, such as 3A/480VAC, 0.8A/120VDC, etc.