Handheld Hydrogen Sulfide (H2S) Gas Detector, 0 to 50/100/500 ppm

$478.96
This pump-type single gas detector is suitable for detecting the leakage of hydrogen sulfide (H2S), with a range of 0-50ppm, 0-100ppm, 0-200ppm, 0-500ppm etc., for options, and gives light, sound and vibration alarm. Favorable price and high reliability.
SKU: GD200-H2S
*
*
*
Free Shipping
Delivery date: 6-12 days

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-H2S
Sampling MethodPump type, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasHydrogen Sulfide (H2S)
Range (Optional)*0 to 5/10ppm (for Atmosphere), 0 to 20/50/100/200ppm, 0 to 500/1000/2000/3000ppm (for Smoke and Biogas)
Resolution0.001ppm (0-5/10ppm), 0.01ppm (0-20/50ppm), 0.1ppm (0-100/200ppm), 1ppm (0-500/1000/2000/3000ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
CommunicationMini USB interface supports standard MODBUS communication protocol
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube

Note 1:

  • If you require a CO gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Handheld Hydrogen Sulfide (H2S) Gas Detector Details

Applications

Hydrogen sulfide (H2S) detector with pump-suction style is used to monitor the concentrtion of H2S in the dangerous areas like oil recovery, petrochemical, metallurgy, sewage treatment, exhaust emission, chemical, agriculture, refinery and so on.hydrogen sulfide H2S gas detector applications

Tips: Gas characteristics and detection of hydrogen sulfide

Hydrogen sulfide (H2S) is a flammable colorless gas with a typical smell of rotten eggs. It is easily soluble in water; at the temperature of 20℃, 2.9 volume of is soluble in 1 volume of water. Hydrogen sulfide is also soluble in alcohols, aldehydes, carbon disulfide, petroleum solvents and crude oil.

Hydrogen sulfide is five to six times more toxic than carbon monoxide and is almost as toxic as cyanide. At the low concentrations (0.13 - 4.6 ppm), hydrogen sulfide smells rotten eggs. When the H2S concentration is higher than 4.6 ppm, the human sense of smell is quickly passivited and the odour of rotten eggs is not smelled. This situation is the most dangerous.

When the H2S concentration is between 4.3 and 46%, the mixed gas formed with the air will explode in a fire. The burned product, SO2, is still toxic and will continue to harm the eyes and lungs of the human body. The work of preventing poisoning during burning cannot be relaxed.

Hydrogen sulfide (H2S) exists in a wide range of places like natural gas processing plants, refineries, rubber products plants, pulp mills, tunnels, sewers, sewage ponds, biogas digesters, etc. Therefore, it is really necessary to detect H2S gas concentration before the operations in the above-mentioned places.

ATO offers you fixed and portable hydrogen sulfide gas detector. Whether selecting portable or fixed H2S detector should be based on the operating environment. The measure range should also be chosen according to the site conditions, so as to meet the different use requirements. Thus, even in the unfavorable working conditions, the detector can also detect harmful gases and promptly give an alarm to the staff.

Basic Settings of Portable Gas Detector

This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

Calibration of Portable Gas Detector

This video will show how to calibrate the ATO portable gas detectors.

Concentration Detection of Pesticides Gas

Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

How to Detect Hydrogen Sulfide Concentration in the Toilet

Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

How much C2H4 (ethylene) do ripe bananas and apples produce?

We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

How Does a Portable Detector Work?

This video explains how a portable detector works and uses it to measure the air around you.

Portable Single Gas Detector Parameter Settings

In this video, we show you the menu settings of the ATO portable detector. Five button operation makes it very simple to control and activate functions. This device provides two alarm types, high alarm point and low alarm point, which can be adjusted as needed. The speed of the pump is also allowed to be adjusted. Calibration options include zero calibration and span calibration, both of which should be performed by qualified professionals under strict operating conditions using necessary accessories and standard gases.

How to Calibrate a Portable Gas Detector?

This video shows how to calibrate a portable gas detector. The ATO portable gas detector is lithium battery powered, has data logging capabilities and is available with a calibration kit.

Gas Detector Detection Range Setting

This video demonstrates the detection range setting of a portable gas detector.

Product reviews
Optional function for hydrogen sulfide gas detector
5
Blake
Avatar
9/5/2019 7:01 PM
What’s the necessity for optional function for hydrogen sulfide gas detector?
Was this review helpful? Yes No (0/0)
ATO Responded
Dear friend, the optional function of H2S gas detector is to connect the gas detector to your computer via USB for data downloading and printing. It depends on your needs.
Detection distance for your portable gas detector
5
Frank
Avatar
4/22/2020 7:00 PM
What is the detection distance for your portable gas detector?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi Frank. For our portable gas detector, the detection distance is 15m.
H2S gas detector data logging
5
Gregory
Avatar
4/29/2020 7:22 PM
I am looking for a H2S gas detector with data logging function, how does your portable gas detector log data?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi Gregory.  Our portable gas detector can automatically save gas ppm value, and these data can be downloaded to the computer via the proivded software and USB connection.
Hydrogen Sulfide (H2S) Gas Detector calibration
5
Herna
Avatar
5/11/2020 6:51 PM
Does your Hydrogen Sulfide (H2S) Gas Detector require periodical calibration (it should be self-calibrated)?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Herna. Our gas detector has a zero calibration function, and you can use it on site If any abnormal. For periodical calibration, it’s recommended to be done once every year.
Gas detector working pressure
5
Brandon
Avatar
7/23/2020 6:57 PM
Can your gas detector work in the 1-5 bar pressure environment?
Was this review helpful? Yes No (0/0)
ATO Responded
No, it doesn't work with our gas detectors. For the pressure 1-5 bar, you need to reduce the pressure to less than 1 bar, as our gas detector can only withstand the pressure within 1 bar. So, you can add a pressure reducing valve before the gas detector.
H2S detector with other measuring range
5
Rick
Avatar
1/14/2021 7:36 PM
Can you provide handheld H2S detector with 0-10000ppm range because it is not available online : maximum range available is 0-1000ppm?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can customize the H2S Gas Detector with the range of  0-10000 ppm, but its service life will be only one month.
Can your handheld hydrogen sulfide connect to the standard MODBUS communication protocol?
5
Celine
Avatar
10/28/2021 8:35 PM
Could your handheld hydrogen sulfide be connected to standard MODBUS communication protocol?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it has mini USB interface supports standard MODBUS communication protocol, but you have design your APP yourself in order to use the portable gas detector RS485 communication.
Solved my gas leak problem
5
Mateo
Avatar
4/19/2022 2:12 AM
Buy a gas detector for RV gas detection, small size, save space, just in the second week of using the detector, I found a small leak from the stove, I am very grateful for this hydrogen sulfide gas detector, provide effective testing for my family's health.
Was this review helpful? Yes No (0/0)
GREAT PURCHASE!!! Saved My Family!!!
5
Paradox
Avatar
5/25/2022 3:24 AM
This gas detector is absolutely GREAT!!!! It detected 4 Small Leaks of natural gas in my Boiler Room that I couldn't even smell. I thought it was inaccurate but I'm wrong! Behold, It Was Accurate! Now they are repaired. If you use it correctly, IT WORKS GREAT!!
Was this review helpful? Yes No (0/0)
We need the password for calibration mode
4
Alva
Avatar
10/18/2024 12:05 AM
We have the SKU: GD200 0-10ppm measuring range model of this H2S detector. We are required to calibrate monthly and require the password for calibration mode.
Was this review helpful? Yes No (0/0)
ATO Responded
The password is 2020, you can try it. Regarding calibration, you can refer to this video, see on: https://www.youtube.com/watch?v=Tr8UfiQe_S8&list=PLlo8RulDRntipAoQ0eNwGr6LKogcxjl5F&index=7
H2S Gas Detector
5
Teltsch
Avatar
6/24/2025 7:27 PM
I am looking for an H2S gas detector that can measure concentrations from 0 to 50 ppm with a resolution of at least 0.01 ppm. In addition, I need the device to be able to output data via a serial or analog interface. Which devices meet these specifications? Can the GD200-H2S output serial data? What is the sampling interval? How fast is the data output?
Was this review helpful? Yes No (0/0)
ATO Responded
The RS485 communication sampling interval of the GD200-H2S is expected to be around 5ms. The sampling time and the speed of outputting data can be mentioned in the communication protocol.
Maximum operating pressure
5
Sester
Avatar
6/24/2026 12:20 AM
Based on our requirements, we need a detector that measures only hydrogen sulfide (H₂S) concentration, with a measurement range up to 1000 ppm. What is the maximum operating pressure for this detector?
Was this review helpful? Yes No (0/0)
ATO Responded
You can check out our GD200-H2S detector; its operating pressure is 0.8~1.2 bar.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-H2S
Sampling MethodPump type, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasHydrogen Sulfide (H2S)
Range (Optional)*0 to 5/10ppm (for Atmosphere), 0 to 20/50/100/200ppm, 0 to 500/1000/2000/3000ppm (for Smoke and Biogas)
Resolution0.001ppm (0-5/10ppm), 0.01ppm (0-20/50ppm), 0.1ppm (0-100/200ppm), 1ppm (0-500/1000/2000/3000ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
CommunicationMini USB interface supports standard MODBUS communication protocol
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube

Note 1:

  • If you require a CO gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Handheld Hydrogen Sulfide (H2S) Gas Detector Details

Applications

Hydrogen sulfide (H2S) detector with pump-suction style is used to monitor the concentrtion of H2S in the dangerous areas like oil recovery, petrochemical, metallurgy, sewage treatment, exhaust emission, chemical, agriculture, refinery and so on.hydrogen sulfide H2S gas detector applications

Tips: Gas characteristics and detection of hydrogen sulfide

Hydrogen sulfide (H2S) is a flammable colorless gas with a typical smell of rotten eggs. It is easily soluble in water; at the temperature of 20℃, 2.9 volume of is soluble in 1 volume of water. Hydrogen sulfide is also soluble in alcohols, aldehydes, carbon disulfide, petroleum solvents and crude oil.

Hydrogen sulfide is five to six times more toxic than carbon monoxide and is almost as toxic as cyanide. At the low concentrations (0.13 - 4.6 ppm), hydrogen sulfide smells rotten eggs. When the H2S concentration is higher than 4.6 ppm, the human sense of smell is quickly passivited and the odour of rotten eggs is not smelled. This situation is the most dangerous.

When the H2S concentration is between 4.3 and 46%, the mixed gas formed with the air will explode in a fire. The burned product, SO2, is still toxic and will continue to harm the eyes and lungs of the human body. The work of preventing poisoning during burning cannot be relaxed.

Hydrogen sulfide (H2S) exists in a wide range of places like natural gas processing plants, refineries, rubber products plants, pulp mills, tunnels, sewers, sewage ponds, biogas digesters, etc. Therefore, it is really necessary to detect H2S gas concentration before the operations in the above-mentioned places.

ATO offers you fixed and portable hydrogen sulfide gas detector. Whether selecting portable or fixed H2S detector should be based on the operating environment. The measure range should also be chosen according to the site conditions, so as to meet the different use requirements. Thus, even in the unfavorable working conditions, the detector can also detect harmful gases and promptly give an alarm to the staff.

Product reviews
Optional function for hydrogen sulfide gas detector
5
Blake
Avatar
9/5/2019 7:01 PM
What’s the necessity for optional function for hydrogen sulfide gas detector?
Was this review helpful? Yes No (0/0)
ATO Responded
Dear friend, the optional function of H2S gas detector is to connect the gas detector to your computer via USB for data downloading and printing. It depends on your needs.
Detection distance for your portable gas detector
5
Frank
Avatar
4/22/2020 7:00 PM
What is the detection distance for your portable gas detector?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi Frank. For our portable gas detector, the detection distance is 15m.
H2S gas detector data logging
5
Gregory
Avatar
4/29/2020 7:22 PM
I am looking for a H2S gas detector with data logging function, how does your portable gas detector log data?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi Gregory.  Our portable gas detector can automatically save gas ppm value, and these data can be downloaded to the computer via the proivded software and USB connection.
Hydrogen Sulfide (H2S) Gas Detector calibration
5
Herna
Avatar
5/11/2020 6:51 PM
Does your Hydrogen Sulfide (H2S) Gas Detector require periodical calibration (it should be self-calibrated)?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Herna. Our gas detector has a zero calibration function, and you can use it on site If any abnormal. For periodical calibration, it’s recommended to be done once every year.
Gas detector working pressure
5
Brandon
Avatar
7/23/2020 6:57 PM
Can your gas detector work in the 1-5 bar pressure environment?
Was this review helpful? Yes No (0/0)
ATO Responded
No, it doesn't work with our gas detectors. For the pressure 1-5 bar, you need to reduce the pressure to less than 1 bar, as our gas detector can only withstand the pressure within 1 bar. So, you can add a pressure reducing valve before the gas detector.
H2S detector with other measuring range
5
Rick
Avatar
1/14/2021 7:36 PM
Can you provide handheld H2S detector with 0-10000ppm range because it is not available online : maximum range available is 0-1000ppm?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can customize the H2S Gas Detector with the range of  0-10000 ppm, but its service life will be only one month.
Can your handheld hydrogen sulfide connect to the standard MODBUS communication protocol?
5
Celine
Avatar
10/28/2021 8:35 PM
Could your handheld hydrogen sulfide be connected to standard MODBUS communication protocol?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it has mini USB interface supports standard MODBUS communication protocol, but you have design your APP yourself in order to use the portable gas detector RS485 communication.
Solved my gas leak problem
5
Mateo
Avatar
4/19/2022 2:12 AM
Buy a gas detector for RV gas detection, small size, save space, just in the second week of using the detector, I found a small leak from the stove, I am very grateful for this hydrogen sulfide gas detector, provide effective testing for my family's health.
Was this review helpful? Yes No (0/0)
GREAT PURCHASE!!! Saved My Family!!!
5
Paradox
Avatar
5/25/2022 3:24 AM
This gas detector is absolutely GREAT!!!! It detected 4 Small Leaks of natural gas in my Boiler Room that I couldn't even smell. I thought it was inaccurate but I'm wrong! Behold, It Was Accurate! Now they are repaired. If you use it correctly, IT WORKS GREAT!!
Was this review helpful? Yes No (0/0)
We need the password for calibration mode
4
Alva
Avatar
10/18/2024 12:05 AM
We have the SKU: GD200 0-10ppm measuring range model of this H2S detector. We are required to calibrate monthly and require the password for calibration mode.
Was this review helpful? Yes No (0/0)
ATO Responded
The password is 2020, you can try it. Regarding calibration, you can refer to this video, see on: https://www.youtube.com/watch?v=Tr8UfiQe_S8&list=PLlo8RulDRntipAoQ0eNwGr6LKogcxjl5F&index=7
H2S Gas Detector
5
Teltsch
Avatar
6/24/2025 7:27 PM
I am looking for an H2S gas detector that can measure concentrations from 0 to 50 ppm with a resolution of at least 0.01 ppm. In addition, I need the device to be able to output data via a serial or analog interface. Which devices meet these specifications? Can the GD200-H2S output serial data? What is the sampling interval? How fast is the data output?
Was this review helpful? Yes No (0/0)
ATO Responded
The RS485 communication sampling interval of the GD200-H2S is expected to be around 5ms. The sampling time and the speed of outputting data can be mentioned in the communication protocol.
Maximum operating pressure
5
Sester
Avatar
6/24/2026 12:20 AM
Based on our requirements, we need a detector that measures only hydrogen sulfide (H₂S) concentration, with a measurement range up to 1000 ppm. What is the maximum operating pressure for this detector?
Was this review helpful? Yes No (0/0)
ATO Responded
You can check out our GD200-H2S detector; its operating pressure is 0.8~1.2 bar.
Only registered users can write reviews
Customers who bought this item also bought

Handheld Ammonia (NH3) Gas Detector, 0 to 50/100/500 ppm

GD200-NH3
$828.16
Low price handheld pumping-type gas detector provides the Ammonia (NH3) gas leak monitoring with high accuracy sensor, audible and visual alarm, optional measuring range 0 to 50ppm, 0 to 100ppm, 0 to 200ppm, 0 to 500ppm etc., LCD display, easy readout, small & portable design, convenient to carry.