Laboratory Water Purification System, RO, Type 3

$3,718.15
Hot sell lab ultra pure reverse osmosis water purification system with low price, produces Type III water / distilled water straight from tap water, conductivity of the outlet water is 0-10us/cm, suitable for general chemical/physical testing of laboratory instruments, solution preparation.
SKU: ATO-WPS-Moro210
*
*
Free Shipping
Delivery date: 6-12 days

Economical laboratory single/double stage RO water purifier system, meet general chemical analysis, laboratory equipment washing, cleaning, conventional water for testing center, pure water for autoclave.

Specification

ModelMoro210s/ 220s/ 230sMoro210d/ 220d/ 230d
ProcessSingle pass RO systemDouble pass RO system
Output of pure water≥10L/H≥10L/H
Flow rate (with pure water tank)≥1-1.5L/min≥1-1.5L/min
Conductivity at 25℃≤10μs/cm≤5μs/cm
PH5.0-7.55.0-7.5
Oxidizabes (as O)≤0.4mg/L≤0.4mg/L
Evaporation residue≤2.0mg/L≤2.0mg/L
Electrical requirements220V (230V, 240V) 50Hz
Power≥100W≥150W
Dimension (L/W/H)340*550*530mm340*550*530mm
Weight≥30KG≥35KG
Tank capacity210s/210d (3 Gallon pressure tank)
220s/220d (6.5 Gallon pressure tank)
230s/230d (10 Gallon pressure tank)

Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

Product Features
Integrated tabletop water purifier for Type III water.
Pure deionized/distilled water.
Built-in RO membrane anti-scaling program, RO membrane cleaning manual button.
Easy to clean, disinfect and discharge waste water.
Conductivity is displayed on the LED screen.
Variable outlet capacity from 5LPH to 100LPH.

Lab Test and Corresponding Water Type List

Test NameType III WaterType II WaterType I Water
Lab glassware washing√
Hydroponics√
Sterilizer use water√
Gas generator use water√√
Conventional test√
Reagents/ drugs preparation, dilution√
Feed water for ultrapure water√
IC√
LC/LC-MS√
HPLC√
AAS√
ICP/ICP-MS√
GC/GC-MS√
Trace analysis√
TOC analysis√
Organic analysis√
Inorganic analysis√
Environmental analytical test√
Microelectronics parts cleaning√
Precision instrument use water√
Analytical reagent/ drugs preparation, dilution√
Mass spectrometry√
PCR application/analysis√
DNA/RNA research√
Proteomics research√
Plant and animal cell culture√
Toxicity analysis√
Microbiology experiment√
Immunological experiment√
Biochemistry experiment√
Serum test√
IVF√

Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

No.NameSpecificationLifespan
1PP filter1st stage, 10”/20” (5μm)3-6 months
2Activated Carbon filter2nd stage, 10”/20”6-12 months
3Softener filter3rd stage, 10”/20”6-12 months
4Precision filter4th stage, 10”/20” (1μm)10-12 months
5RO membrane75g/300g1-2 years
6Ultra purification resin column1 year
7Micro filter0.22μm1 year
8UV lamp185/254nm8000 hours
9Pure water tank30L, 80L, 120L

Tips: How to avoid damage to reverse osmosis (RO) membrane?
There are many situations that cause reverse osmosis membrane damage. In the daily experiment process, laboratory personnel do not pay much attention to the use of equipment, so the service life of the ultrapure water system is also shortened. What should be paid attention to in daily use?
1. Raw water quality
The water used in the laboratory is mostly tap water, and the quality of the water source varies from region to region. The macromolecular substances in the raw water are not completely removed and pass into the reverse osmosis membrane when they pass through the pre-treatment device of the laboratory purification water system, which easily causes the reverse osmosis membrane to be blocked.
2. Improper operation
The residual gas in the purification water system runs under high pressure, and the formation of an air hammer will damage the RO membrane. Therefore, it must be ensured that the remaining air is exhausted under the pressure of 2 to 4 bar, and then the pressure is gradually increased.
If the device is turned on repeatedly, it will cause unstable pump pressure and even cause RO membrane breakdown.
3. Poor disinfection
If the RO membrane is used for a long period of time without regular disinfection or good disinfection, it will also cause the membrane to be contaminated with a large number of microorganisms, and long-term accumulation will cause damage to the RO membrane.
4. RO membrane pre-treatment filter is not maintained properly
Pre-treatment is mainly used to filter large particulate matter, colloids, gas, etc. in water quality, and these materials also cause great damage to RO reverse osmosis. Internally filled activated carbon generally needs to be replaced within 1-3 years, and PP cotton needs to be replaced within 6-12 months.
5. Not used for a long time
When the ultra-pure water machine is not used for a long time, the RO membrane will dry out, and the filtered impurities will be fixed on the RO membrane. When we use it again, tap water cannot pass through the RO membrane. So even if we don’t use water, we still need to turn on the machine from time to time to clear the inside.

Product reviews
Excellent laboratory water purification system.
5
Alex
Avatar
3/28/2022 6:53 PM
I've owned this water puritfication system for two months, now, and I can't say enough good things about it. It is well-designed little unit that's also very easy to use. I believe it will be durable, and time will tell.
Was this review helpful? Yes No (0/0)
High quality of Water Purification System
5
Tylor
Avatar
12/6/2022 11:25 PM
I just got this water filter. Have to say it works so great. It can filter out impurities, and
to install a faucet to take water conveniently. Small size, easy to take.  I am very satisfied
with this machine.
Was this review helpful? Yes No (0/0)
Great water purification system
5
Andrew
Avatar
2/20/2023 12:30 AM
I recently purchased the ATO lab water purification system and have been extremely satisfied with its performance. The system has effectively removed impurities from our tap water, resulting in clean and consistent water quality for our experiments. This filter has been great so far and was very easy to install. Would recommend!
Was this review helpful? Yes No (0/0)
Solve problem of water purification system
5
Elfie
Avatar
3/1/2023 8:55 PM
Now the system is in operation and we send a sample for testing.
The report is attached but does not meet the electrical conductivity (ISO 3696) as standard.
Kindly advise us for achievement of required reading.
We hope ato support us and resolve the issue.
Was this review helpful? Yes No (0/0)
ATO Responded
1.  You can press the RO button to rinse, and then turn to open the blue filter bottle (pretreatment filter) to see if the color has changed.
If it turns yellow or black, it means that the filter element is dead and needs to be replaced.
2.  Please check the conductance displayed on our machine.
Sometimes there are deviations between the offline test and the online test data.
So if the conductivity on the machine is qualified, it proves that the water quality is good.
The details of the cartridge micron of water purification.
5
rabbie
Avatar
3/1/2023 11:23 PM
Today here holiday so we will check tomorrow as you advised.
If we replace the filter cartridge kindly send us the details of the cartridge micron.
Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
Grade 1 PP Molcot20: 5 microns    
Grade 3 PP Molpp20: 1 micron
Really happy with this system
5
Chandler
Avatar
10/21/2025 8:54 PM
It was easy to set up and gives consistently pure water for all my lab work. Quiet, compact, and honestly one of the best additions to my workspace.
Was this review helpful? Yes No (0/0)
Perfect for daily lab testing and equipment cleaning
4
Logan
Avatar
11/10/2025 7:48 PM
The water quality remains clean and stable, while the machine operates quietly. Its anti-scaling feature works wonders for extending membrane longevity, and the compact design helps save precious bench space.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Economical laboratory single/double stage RO water purifier system, meet general chemical analysis, laboratory equipment washing, cleaning, conventional water for testing center, pure water for autoclave.

Specification

ModelMoro210s/ 220s/ 230sMoro210d/ 220d/ 230d
ProcessSingle pass RO systemDouble pass RO system
Output of pure water≥10L/H≥10L/H
Flow rate (with pure water tank)≥1-1.5L/min≥1-1.5L/min
Conductivity at 25℃≤10μs/cm≤5μs/cm
PH5.0-7.55.0-7.5
Oxidizabes (as O)≤0.4mg/L≤0.4mg/L
Evaporation residue≤2.0mg/L≤2.0mg/L
Electrical requirements220V (230V, 240V) 50Hz
Power≥100W≥150W
Dimension (L/W/H)340*550*530mm340*550*530mm
Weight≥30KG≥35KG
Tank capacity210s/210d (3 Gallon pressure tank)
220s/220d (6.5 Gallon pressure tank)
230s/230d (10 Gallon pressure tank)

Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

Product Features
Integrated tabletop water purifier for Type III water.
Pure deionized/distilled water.
Built-in RO membrane anti-scaling program, RO membrane cleaning manual button.
Easy to clean, disinfect and discharge waste water.
Conductivity is displayed on the LED screen.
Variable outlet capacity from 5LPH to 100LPH.

Lab Test and Corresponding Water Type List

Test NameType III WaterType II WaterType I Water
Lab glassware washing√
Hydroponics√
Sterilizer use water√
Gas generator use water√√
Conventional test√
Reagents/ drugs preparation, dilution√
Feed water for ultrapure water√
IC√
LC/LC-MS√
HPLC√
AAS√
ICP/ICP-MS√
GC/GC-MS√
Trace analysis√
TOC analysis√
Organic analysis√
Inorganic analysis√
Environmental analytical test√
Microelectronics parts cleaning√
Precision instrument use water√
Analytical reagent/ drugs preparation, dilution√
Mass spectrometry√
PCR application/analysis√
DNA/RNA research√
Proteomics research√
Plant and animal cell culture√
Toxicity analysis√
Microbiology experiment√
Immunological experiment√
Biochemistry experiment√
Serum test√
IVF√

Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

No.NameSpecificationLifespan
1PP filter1st stage, 10”/20” (5μm)3-6 months
2Activated Carbon filter2nd stage, 10”/20”6-12 months
3Softener filter3rd stage, 10”/20”6-12 months
4Precision filter4th stage, 10”/20” (1μm)10-12 months
5RO membrane75g/300g1-2 years
6Ultra purification resin column1 year
7Micro filter0.22μm1 year
8UV lamp185/254nm8000 hours
9Pure water tank30L, 80L, 120L

Tips: How to avoid damage to reverse osmosis (RO) membrane?
There are many situations that cause reverse osmosis membrane damage. In the daily experiment process, laboratory personnel do not pay much attention to the use of equipment, so the service life of the ultrapure water system is also shortened. What should be paid attention to in daily use?
1. Raw water quality
The water used in the laboratory is mostly tap water, and the quality of the water source varies from region to region. The macromolecular substances in the raw water are not completely removed and pass into the reverse osmosis membrane when they pass through the pre-treatment device of the laboratory purification water system, which easily causes the reverse osmosis membrane to be blocked.
2. Improper operation
The residual gas in the purification water system runs under high pressure, and the formation of an air hammer will damage the RO membrane. Therefore, it must be ensured that the remaining air is exhausted under the pressure of 2 to 4 bar, and then the pressure is gradually increased.
If the device is turned on repeatedly, it will cause unstable pump pressure and even cause RO membrane breakdown.
3. Poor disinfection
If the RO membrane is used for a long period of time without regular disinfection or good disinfection, it will also cause the membrane to be contaminated with a large number of microorganisms, and long-term accumulation will cause damage to the RO membrane.
4. RO membrane pre-treatment filter is not maintained properly
Pre-treatment is mainly used to filter large particulate matter, colloids, gas, etc. in water quality, and these materials also cause great damage to RO reverse osmosis. Internally filled activated carbon generally needs to be replaced within 1-3 years, and PP cotton needs to be replaced within 6-12 months.
5. Not used for a long time
When the ultra-pure water machine is not used for a long time, the RO membrane will dry out, and the filtered impurities will be fixed on the RO membrane. When we use it again, tap water cannot pass through the RO membrane. So even if we don’t use water, we still need to turn on the machine from time to time to clear the inside.

Product reviews
Excellent laboratory water purification system.
5
Alex
Avatar
3/28/2022 6:53 PM
I've owned this water puritfication system for two months, now, and I can't say enough good things about it. It is well-designed little unit that's also very easy to use. I believe it will be durable, and time will tell.
Was this review helpful? Yes No (0/0)
High quality of Water Purification System
5
Tylor
Avatar
12/6/2022 11:25 PM
I just got this water filter. Have to say it works so great. It can filter out impurities, and
to install a faucet to take water conveniently. Small size, easy to take.  I am very satisfied
with this machine.
Was this review helpful? Yes No (0/0)
Great water purification system
5
Andrew
Avatar
2/20/2023 12:30 AM
I recently purchased the ATO lab water purification system and have been extremely satisfied with its performance. The system has effectively removed impurities from our tap water, resulting in clean and consistent water quality for our experiments. This filter has been great so far and was very easy to install. Would recommend!
Was this review helpful? Yes No (0/0)
Solve problem of water purification system
5
Elfie
Avatar
3/1/2023 8:55 PM
Now the system is in operation and we send a sample for testing.
The report is attached but does not meet the electrical conductivity (ISO 3696) as standard.
Kindly advise us for achievement of required reading.
We hope ato support us and resolve the issue.
Was this review helpful? Yes No (0/0)
ATO Responded
1.  You can press the RO button to rinse, and then turn to open the blue filter bottle (pretreatment filter) to see if the color has changed.
If it turns yellow or black, it means that the filter element is dead and needs to be replaced.
2.  Please check the conductance displayed on our machine.
Sometimes there are deviations between the offline test and the online test data.
So if the conductivity on the machine is qualified, it proves that the water quality is good.
The details of the cartridge micron of water purification.
5
rabbie
Avatar
3/1/2023 11:23 PM
Today here holiday so we will check tomorrow as you advised.
If we replace the filter cartridge kindly send us the details of the cartridge micron.
Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
Grade 1 PP Molcot20: 5 microns    
Grade 3 PP Molpp20: 1 micron
Really happy with this system
5
Chandler
Avatar
10/21/2025 8:54 PM
It was easy to set up and gives consistently pure water for all my lab work. Quiet, compact, and honestly one of the best additions to my workspace.
Was this review helpful? Yes No (0/0)
Perfect for daily lab testing and equipment cleaning
4
Logan
Avatar
11/10/2025 7:48 PM
The water quality remains clean and stable, while the machine operates quietly. Its anti-scaling feature works wonders for extending membrane longevity, and the compact design helps save precious bench space.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews