Lab Water Purification System for Biochemical Analyzer

$5,456.56
Excellent price lab RO water treatment equipment, specially made for blood station / research lab / clinical laboratory in hospital / biochemical analyzer, provides Type II and Type III deionized water, ≥ 5MΩ-cm resistivity, supplied to Roche, Hitachi, Olympus, Siemens, Mindray etc biochemistry analyzers.
SKU: ATO-WPS-Mobiochem910
*
*
Free Shipping
Delivery date: 6-12 days

High quality laboratory ultra-pure water system for biochemical analyzer matched used, adopt PP, AC filter, RO membrane, purification column, final filter and other technologies.

Specification

ModelMobiochem910s/ 920s/ 930sMobiochem910d/ 920d/ 930d
ProcessSingle pass RO systemDouble pass RO system
Water production capacity≥10L/H≥10L/H
Water output rate1-1.5L/min1-1.5L/min
Resistivity at 25℃≥5MΩ.cm≥5MΩ.cm
Absorbance (254nm,1cm optical distance)≤ 0.01≤ 0.01
Reactive Silica (SiO2)≤ 0.02ppm≤ 0.02ppm
Heavy metal< 0.01ppm< 0.01ppm
Electrical requirements220V (230V, 240V) 50Hz
Power≥100W≥150W
Dimension (L/W/H)490*550*850mm490*550*850mm
Weight≥50KG≥55KG
Tank capacity30L

Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

Product Features
Power on self test, water shortage protection alarm, power-off protection.
Built-in RO membrane fouling prevention program, auto flushing when open and manual RO membrane cleaning button.
Built-in automatic cycle timing of ultra pure water, ultra pure water conservation.
Water resistance/conductivity on-line monitoring, display the running state and parameters.
Pure water tank with cone type structure, a discharge valve at the bottom, easy to clean and disinfect exhausted. Water level auto detection.

Lab Test and Corresponding Water Type List

Test NameType III WaterType II WaterType I Water
Lab glassware washing√
Hydroponics√
Sterilizer use water√
Gas generator use water√√
Conventional test√
Reagents/ drugs preparation, dilution√
Feed water for ultrapure water√
IC√
LC/LC-MS√
HPLC√
AAS√
ICP/ICP-MS√
GC/GC-MS√
Trace analysis√
TOC analysis√
Organic analysis√
Inorganic analysis√
Environmental analytical test√
Microelectronics parts cleaning√
Precision instrument use water√
Analytical reagent/ drugs preparation, dilution√
Mass spectrometry√
PCR application/analysis√
DNA/RNA research√
Proteomics research√
Plant and animal cell culture√
Toxicity analysis√
Microbiology experiment√
Immunological experiment√
Biochemistry experiment√
Serum test√
IVF√

Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

No.NameSpecificationLifespan
1PP filter1st stage, 10”/20” (5μm)3-6 months
2Activated Carbon filter2nd stage, 10”/20”6-12 months
3Softener filter3rd stage, 10”/20”6-12 months
4Precision filter4th stage, 10”/20” (1μm)10-12 months
5RO membrane75g/300g1-2 years
6Ultra purification resin column1 year
7Pure water tank30L, 80L, 120L

Tips: Laboratory purification water system freezes easily in winter.
If the laboratory purification water system is installed outdoors, the necessary anti-freezing measures must be taken, otherwise this will cause damage to parts. Stop using the laboratory ultrapure water system as soon as the temperature is below 0 ° C.
If it is installed indoors, the temperature must be higher than 0 ℃. If the temperature is too low, the pipes will be cracked and leak.
If you do not use for a long time or need to go out, you must close the water inlet valve to drain all the water from the device.
If you encounter icing, you need to place the entire device in a room with a temperature higher than 10 ° C for 48 hours before you can continue to use it. During this thawing period, do not open the machine.

Product reviews
This product works well in our lab.
5
Adam
Avatar
6/17/2024 1:09 AM
The water purification system came as expected. The installation was smooth, and since then, it has consistently delivered high-quality water, crucial for our assays. It's reliable under heavy daily use and compatible with our Olympus analyzer. I highly recommend it for any lab needing dependable water purity for critical analysis.
Was this review helpful? Yes No (0/0)
good water purification system
4
Vera
Avatar
11/5/2025 2:04 AM
We've been using this lab water purification system for biochemical analyzer for several months now. It does take up a bit more space than we expected, but the automatic monitoring features make daily operation so convenient.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High quality laboratory ultra-pure water system for biochemical analyzer matched used, adopt PP, AC filter, RO membrane, purification column, final filter and other technologies.

Specification

ModelMobiochem910s/ 920s/ 930sMobiochem910d/ 920d/ 930d
ProcessSingle pass RO systemDouble pass RO system
Water production capacity≥10L/H≥10L/H
Water output rate1-1.5L/min1-1.5L/min
Resistivity at 25℃≥5MΩ.cm≥5MΩ.cm
Absorbance (254nm,1cm optical distance)≤ 0.01≤ 0.01
Reactive Silica (SiO2)≤ 0.02ppm≤ 0.02ppm
Heavy metal< 0.01ppm< 0.01ppm
Electrical requirements220V (230V, 240V) 50Hz
Power≥100W≥150W
Dimension (L/W/H)490*550*850mm490*550*850mm
Weight≥50KG≥55KG
Tank capacity30L

Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

Product Features
Power on self test, water shortage protection alarm, power-off protection.
Built-in RO membrane fouling prevention program, auto flushing when open and manual RO membrane cleaning button.
Built-in automatic cycle timing of ultra pure water, ultra pure water conservation.
Water resistance/conductivity on-line monitoring, display the running state and parameters.
Pure water tank with cone type structure, a discharge valve at the bottom, easy to clean and disinfect exhausted. Water level auto detection.

Lab Test and Corresponding Water Type List

Test NameType III WaterType II WaterType I Water
Lab glassware washing√
Hydroponics√
Sterilizer use water√
Gas generator use water√√
Conventional test√
Reagents/ drugs preparation, dilution√
Feed water for ultrapure water√
IC√
LC/LC-MS√
HPLC√
AAS√
ICP/ICP-MS√
GC/GC-MS√
Trace analysis√
TOC analysis√
Organic analysis√
Inorganic analysis√
Environmental analytical test√
Microelectronics parts cleaning√
Precision instrument use water√
Analytical reagent/ drugs preparation, dilution√
Mass spectrometry√
PCR application/analysis√
DNA/RNA research√
Proteomics research√
Plant and animal cell culture√
Toxicity analysis√
Microbiology experiment√
Immunological experiment√
Biochemistry experiment√
Serum test√
IVF√

Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

No.NameSpecificationLifespan
1PP filter1st stage, 10”/20” (5μm)3-6 months
2Activated Carbon filter2nd stage, 10”/20”6-12 months
3Softener filter3rd stage, 10”/20”6-12 months
4Precision filter4th stage, 10”/20” (1μm)10-12 months
5RO membrane75g/300g1-2 years
6Ultra purification resin column1 year
7Pure water tank30L, 80L, 120L

Tips: Laboratory purification water system freezes easily in winter.
If the laboratory purification water system is installed outdoors, the necessary anti-freezing measures must be taken, otherwise this will cause damage to parts. Stop using the laboratory ultrapure water system as soon as the temperature is below 0 ° C.
If it is installed indoors, the temperature must be higher than 0 ℃. If the temperature is too low, the pipes will be cracked and leak.
If you do not use for a long time or need to go out, you must close the water inlet valve to drain all the water from the device.
If you encounter icing, you need to place the entire device in a room with a temperature higher than 10 ° C for 48 hours before you can continue to use it. During this thawing period, do not open the machine.

Product reviews
This product works well in our lab.
5
Adam
Avatar
6/17/2024 1:09 AM
The water purification system came as expected. The installation was smooth, and since then, it has consistently delivered high-quality water, crucial for our assays. It's reliable under heavy daily use and compatible with our Olympus analyzer. I highly recommend it for any lab needing dependable water purity for critical analysis.
Was this review helpful? Yes No (0/0)
good water purification system
4
Vera
Avatar
11/5/2025 2:04 AM
We've been using this lab water purification system for biochemical analyzer for several months now. It does take up a bit more space than we expected, but the automatic monitoring features make daily operation so convenient.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews