RO Water Purification System, <20ppb TOC, Type 1 & 3

$4,919.23
Lab reverse osmosis deionized water purification system on sale, tap water filtered to Type I and Type III ultrapure water, 18.2 megohm resistivity and less than 20ppb TOC, applied to atomic absorption/ atomic emission spectroscopy, toxicity test, quantitative analysis of trace element, buffer solution, GC, IC, HPLC etc.
SKU: ATO-WPS-Moatom510
*
*
Free Shipping
Delivery date: 6-12 days

Low cost 10L per hour laboratory water ultrapurifier with 30L tank and metal plate housing, IC microcomputer intelligent control/Full automatic PLC control, ultrapure water & pure water from one unit.

Specification

ModelMoatom510s/ 520s/ 530sMoatom510d/ 520d/ 530d
ProcessSingle pass RO systemDouble pass RO system
Output of pure water≥10L/H≥10L/H
Output of ultrapure water≥ 1-1.5L/min≥ 1-1.5L/min
Resistivity at 25℃18.25MΩ.cm18.25MΩ.cm
Conductivity at 25℃≤10μs/cm≤5μs/cm
TOC< 20ppb< 20ppb
Pyrogens< 0.02EU/ml< 0.02EU/ml
Absorbance (254nm,1cm optical distance)≤ 0.001≤ 0.001
Reactive Silica (SiO2)< 0.01ppm< 0.01ppm
Heavy metal< 0.01ppm< 0.01ppm
Electrical requirements220V (230V, 240V) 50Hz
Power≥100W≥150W
Dimension (L/W/H)340*550*530mm340*550*530mm
Weight≥30KG≥39KG
Tank capacity30L

Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

Product Features
Power-on self-test, water shortage protection alarm, power-off protection.
Built-in RO membrane anti-scaling program, RO membrane manual cleaning button.
Built-in ultra-pure water automatic cycle program, manual cycle button to maintain ultra-pure water quality.
On-line monitoring of water resistance, real-time display of system operating status and warnings.
With water quality and water production upgrade function.
Intelligent large-capacity ultra-purification column with built-in RFID chip.
Digital display the time of regular intake or the water pressure.
Easy to clean, disinfect and drain off waste water.

Lab Test and Corresponding Water Type List

Test NameType III WaterType II WaterType I Water
Lab glassware washing√
Hydroponics√
Sterilizer use water√
Gas generator use water√√
Conventional test√
Reagents/ drugs preparation, dilution√
Feed water for ultrapure water√
IC√
LC/LC-MS√
HPLC√
AAS√
ICP/ICP-MS√
GC/GC-MS√
Trace analysis√
TOC analysis√
Organic analysis√
Inorganic analysis√
Environmental analytical test√
Microelectronics parts cleaning√
Precision instrument use water√
Analytical reagent/ drugs preparation, dilution√
Mass spectrometry√
PCR application/analysis√
DNA/RNA research√
Proteomics research√
Plant and animal cell culture√
Toxicity analysis√
Microbiology experiment√
Immunological experiment√
Biochemistry experiment√
Serum test√
IVF√

Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

No.NameSpecificationLifespan
1PP filter1st stage, 10”/20” (5μm)3-6 months
2Activated Carbon filter2nd stage, 10”/20”6-12 months
3Softener filter3rd stage, 10”/20”6-12 months
4Precision filter4th stage, 10”/20” (1μm)10-12 months
5RO membrane75g/300g1-2 years
6Ultra purification resin column1 year
7Micro filter0.22μm1 year
8UV lamp185/254nm8000 hours
9Pure water tank30L, 80L, 120L

Tips: Operation process of ATO laboratory ultrapure water system
1. Check whether the water source stainless steel ball valve switch is open and the power cord is connected.
2. Press the power button. At this time, the “system water making” indicator lights up and starts to work normally.
3. Every 2-3 days, please press the "System Wash" button before taking water after booting. At this time, the system is manually cleaned for 1-2 minutes. After washing, press the "System Wash" switch again.
4. Please keep the plastic ball valve on the water storage bucket in the same direction as the pipeline connection. At this time, do not turn off the ball valve switch. Do not twist the vacuum plug on the bottom of the water storage bucket, otherwise the water storage bucket will be scrapped.
5. Pre-processor cleaning: After a period of time when the equipment is in use, the white PP polymer fiber filter starts to change from white to yellow. At this time, remove the bucket of the preprocessor with a special wrench equipped, take out the fiber filter element and wash it with high-pressure tap water. When reinstalling, check whether the plastic pad inside the bucket is properly mated, and make sure that the bucket does not leak after installation. Activated carbon cleaning is the same method. Under normal circumstances, the cleaning time is 2-3 months / times.

Product reviews
I’m loving it so far
5
Eric
Avatar
11/8/2023 2:12 AM
We’ve had this water filter for about 3 months. This system removes chlorine and most all toxins that is in our tap water. It tastes great and we now drink water almost exclusively. We LOVE it.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Low cost 10L per hour laboratory water ultrapurifier with 30L tank and metal plate housing, IC microcomputer intelligent control/Full automatic PLC control, ultrapure water & pure water from one unit.

Specification

ModelMoatom510s/ 520s/ 530sMoatom510d/ 520d/ 530d
ProcessSingle pass RO systemDouble pass RO system
Output of pure water≥10L/H≥10L/H
Output of ultrapure water≥ 1-1.5L/min≥ 1-1.5L/min
Resistivity at 25℃18.25MΩ.cm18.25MΩ.cm
Conductivity at 25℃≤10μs/cm≤5μs/cm
TOC< 20ppb< 20ppb
Pyrogens< 0.02EU/ml< 0.02EU/ml
Absorbance (254nm,1cm optical distance)≤ 0.001≤ 0.001
Reactive Silica (SiO2)< 0.01ppm< 0.01ppm
Heavy metal< 0.01ppm< 0.01ppm
Electrical requirements220V (230V, 240V) 50Hz
Power≥100W≥150W
Dimension (L/W/H)340*550*530mm340*550*530mm
Weight≥30KG≥39KG
Tank capacity30L

Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

Product Features
Power-on self-test, water shortage protection alarm, power-off protection.
Built-in RO membrane anti-scaling program, RO membrane manual cleaning button.
Built-in ultra-pure water automatic cycle program, manual cycle button to maintain ultra-pure water quality.
On-line monitoring of water resistance, real-time display of system operating status and warnings.
With water quality and water production upgrade function.
Intelligent large-capacity ultra-purification column with built-in RFID chip.
Digital display the time of regular intake or the water pressure.
Easy to clean, disinfect and drain off waste water.

Lab Test and Corresponding Water Type List

Test NameType III WaterType II WaterType I Water
Lab glassware washing√
Hydroponics√
Sterilizer use water√
Gas generator use water√√
Conventional test√
Reagents/ drugs preparation, dilution√
Feed water for ultrapure water√
IC√
LC/LC-MS√
HPLC√
AAS√
ICP/ICP-MS√
GC/GC-MS√
Trace analysis√
TOC analysis√
Organic analysis√
Inorganic analysis√
Environmental analytical test√
Microelectronics parts cleaning√
Precision instrument use water√
Analytical reagent/ drugs preparation, dilution√
Mass spectrometry√
PCR application/analysis√
DNA/RNA research√
Proteomics research√
Plant and animal cell culture√
Toxicity analysis√
Microbiology experiment√
Immunological experiment√
Biochemistry experiment√
Serum test√
IVF√

Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

No.NameSpecificationLifespan
1PP filter1st stage, 10”/20” (5μm)3-6 months
2Activated Carbon filter2nd stage, 10”/20”6-12 months
3Softener filter3rd stage, 10”/20”6-12 months
4Precision filter4th stage, 10”/20” (1μm)10-12 months
5RO membrane75g/300g1-2 years
6Ultra purification resin column1 year
7Micro filter0.22μm1 year
8UV lamp185/254nm8000 hours
9Pure water tank30L, 80L, 120L

Tips: Operation process of ATO laboratory ultrapure water system
1. Check whether the water source stainless steel ball valve switch is open and the power cord is connected.
2. Press the power button. At this time, the “system water making” indicator lights up and starts to work normally.
3. Every 2-3 days, please press the "System Wash" button before taking water after booting. At this time, the system is manually cleaned for 1-2 minutes. After washing, press the "System Wash" switch again.
4. Please keep the plastic ball valve on the water storage bucket in the same direction as the pipeline connection. At this time, do not turn off the ball valve switch. Do not twist the vacuum plug on the bottom of the water storage bucket, otherwise the water storage bucket will be scrapped.
5. Pre-processor cleaning: After a period of time when the equipment is in use, the white PP polymer fiber filter starts to change from white to yellow. At this time, remove the bucket of the preprocessor with a special wrench equipped, take out the fiber filter element and wash it with high-pressure tap water. When reinstalling, check whether the plastic pad inside the bucket is properly mated, and make sure that the bucket does not leak after installation. Activated carbon cleaning is the same method. Under normal circumstances, the cleaning time is 2-3 months / times.

Product reviews
I’m loving it so far
5
Eric
Avatar
11/8/2023 2:12 AM
We’ve had this water filter for about 3 months. This system removes chlorine and most all toxins that is in our tap water. It tastes great and we now drink water almost exclusively. We LOVE it.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews