Industrial/Lab Vacuum Oven with Pump

$1,607.38
Industrial/Lab vacuum oven with pump also suitable for commercial use. Chamber capacity of the vacuum oven can select 0.28/0.9/1.9/3.2/15 cu ft, and related specification are customizable. Equipped with high performance temperature controller. According to different models, number of tray is 1~3 pcs, input power 400W~2800W.
SKU: ATO-ILVO-6019
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

Vacuum oven is also called vacuum dryer or vacuum drying oven. It is widely used in chemical and pharmaceutical, food, medical, health, agriculture, environmental protection and other research and application fields. It can baking, drying, heat treat various powders and sterilize various glass containers. The vacuum oven with pump is particularly suitable for fast and effective drying of heat-sensitive, easily decomposed, easily oxidized materials and objects with complex components.

Features of Industrial/Lab Vacuum Oven with Pump

  • Vacuum oven with rotary vacuum pump, rotary vane vacuum pump can effectively and quickly pumping vacuum and offering vacuum condition for vacuum drying operation.
  • Cavity of the vacuum oven is a cuboid, effectively increases the capacity.
  • Vacuum oven uses microcomputer temperature controller, make the data more accurate and reliable.
  • The vacuum dryer uses double-shelf explosion-proof glass door, which is strong and will not deform under ultimate vacuum pressure. Good insulation effect, ensure no heat loss.
  • Drying time of the vacuum oven is minimized. Compared with traditional vacuum drying oven, its the heating time is reduced by more than 50%.
  • Drying, baking, heating and testing are all under vacuum and oxygen-free or filled with inert gas, so materials will not be oxidized.
  • Sealing of the glass door can be adjusted. Sealing and elasticity of the silicone edge band is excellent, fully ensure the temperature and high vacuum inside the vacuum oven

Specification

ModelATO-DZF-6010ATO-DZF-6020ATO-DZF-6050ATO-DZF-6090ATO-DZF-6210ATO-DZF-6500
Input Power (W)4007001400200020602800
Chamber Capacity (L)8255590215430
Chamber Capacity (cu ft)0.280.91.93.27.515
Inner Dimension (W*D*H, mm)200*200*200300*300*270400*400*345450*450*450560*600*640630*810*845
Overall Dimension (W*D*H, mm)630*420*460620*510*480710*580*530610*680*710720*820*17501020*1100*1940
Weigh (kg)7585125155305397
Tray (Pcs)1234
Power Supply (V/Hz)220V/50Hz
110V/60Hz
Shell MaterialSpray-paint Anti-corrosion
Liner Material304 Stainless Steel
Temp. Range (℃)RT+10-200 (250)
Temp. Stability (℃)±1.0
Temp. Analysis (℃)0.1
Working Temp. (℃)+5~40
CertificationCE
Optional ConfigurationExplosion-proof
Packing Listuser manual*1
packing list*1
qualification certificate*1
fuse*2
vacuum connecting pipe*1 (except for model 6090)
spanner*2

Industrial/Lab Vacuum Oven Structure Diagram

Industrial/Lab Vacuum Oven Structure

Industrial/Lab Vacuum Oven Interior Structure

Temperature Controller of Industrial/Lab Vacuum Oven with Pump

Temperature Controller of Industrial/Lab Vacuum Oven

Tips: Failure Treatment for Industrial/Lab Vacuum Oven with Pump

Failure PhenomenaPossible ReasonsTreatment
No power

The out power socket had no power.Check whether the lines are connected well and whether the socket is well.
The power plug is not inserted well in the socket or the line is cut off.Re-insert the plug or repair the line.
The fuse is broken or there is no fuse.Check whether there is any short
circuit.
Replace the fuse (short circuit for apparatus power transformer, short circuit for heater, short circuit for grounding and others short circuit all can cause breaking of fuse.
The temperature does not increaseThe set value is too low.Set temperature SV≥RT+10℃ (RT is environment temperature).
The heater is damaged (short circuit, or open circuit)Replace it.
Use timing function or the setting is not correct.ST=0 or ST=(heating time + constant temperature time.
The cabinet cannot be vacuumized.The vacuum pump is not of the correct model and size.The vacuumizing speed should not be less than 2 L/S.
Various connecting pipe is too loose.Replace it.
The door is not closed well.Adjust the door pin distance.
Product reviews
A Perfect industrial/lab vacuum oven
5
Jackson
Avatar
3/15/2022 2:11 AM
This vacuum oven is what we want. We have bought it for a long time and there is no trouble about the product. The operation is smooth and the quality is good. It is really worth to have a try.
Was this review helpful? Yes No (0/0)
Well-built and durable piece of equipment
5
Osborn
Avatar
2/17/2023 1:21 AM
The interior chamber of this oven is large, I have ample space for samples of various sizes. It's great. And the vacuum pump that comes with the oven is also very powerful and has no trouble achieving the desired vacuum levels quickly. Satisfied purchase!
Was this review helpful? Yes No (0/0)
It's pretty good
4
Leon
Avatar
10/9/2025 9:01 PM
Great little vacuum oven for our lab. The 8L size is perfect for our daily R
Was this review helpful? Yes No (0/0)
Vacuum accuracy
5
Linde
Avatar
3/3/2026 8:21 PM
What is the vacuum accuracy of the ATO-DZF-6010 vacuum oven? Can you provide the product specifications?
Was this review helpful? Yes No (0/0)
ATO Responded
The limit of this vacuum gauge is -0.1 MPa; vacuum accuracy parameters are not currently available.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Vacuum oven is also called vacuum dryer or vacuum drying oven. It is widely used in chemical and pharmaceutical, food, medical, health, agriculture, environmental protection and other research and application fields. It can baking, drying, heat treat various powders and sterilize various glass containers. The vacuum oven with pump is particularly suitable for fast and effective drying of heat-sensitive, easily decomposed, easily oxidized materials and objects with complex components.

Features of Industrial/Lab Vacuum Oven with Pump

  • Vacuum oven with rotary vacuum pump, rotary vane vacuum pump can effectively and quickly pumping vacuum and offering vacuum condition for vacuum drying operation.
  • Cavity of the vacuum oven is a cuboid, effectively increases the capacity.
  • Vacuum oven uses microcomputer temperature controller, make the data more accurate and reliable.
  • The vacuum dryer uses double-shelf explosion-proof glass door, which is strong and will not deform under ultimate vacuum pressure. Good insulation effect, ensure no heat loss.
  • Drying time of the vacuum oven is minimized. Compared with traditional vacuum drying oven, its the heating time is reduced by more than 50%.
  • Drying, baking, heating and testing are all under vacuum and oxygen-free or filled with inert gas, so materials will not be oxidized.
  • Sealing of the glass door can be adjusted. Sealing and elasticity of the silicone edge band is excellent, fully ensure the temperature and high vacuum inside the vacuum oven

Specification

ModelATO-DZF-6010ATO-DZF-6020ATO-DZF-6050ATO-DZF-6090ATO-DZF-6210ATO-DZF-6500
Input Power (W)4007001400200020602800
Chamber Capacity (L)8255590215430
Chamber Capacity (cu ft)0.280.91.93.27.515
Inner Dimension (W*D*H, mm)200*200*200300*300*270400*400*345450*450*450560*600*640630*810*845
Overall Dimension (W*D*H, mm)630*420*460620*510*480710*580*530610*680*710720*820*17501020*1100*1940
Weigh (kg)7585125155305397
Tray (Pcs)1234
Power Supply (V/Hz)220V/50Hz
110V/60Hz
Shell MaterialSpray-paint Anti-corrosion
Liner Material304 Stainless Steel
Temp. Range (℃)RT+10-200 (250)
Temp. Stability (℃)±1.0
Temp. Analysis (℃)0.1
Working Temp. (℃)+5~40
CertificationCE
Optional ConfigurationExplosion-proof
Packing Listuser manual*1
packing list*1
qualification certificate*1
fuse*2
vacuum connecting pipe*1 (except for model 6090)
spanner*2

Industrial/Lab Vacuum Oven Structure Diagram

Industrial/Lab Vacuum Oven Structure

Industrial/Lab Vacuum Oven Interior Structure

Temperature Controller of Industrial/Lab Vacuum Oven with Pump

Temperature Controller of Industrial/Lab Vacuum Oven

Tips: Failure Treatment for Industrial/Lab Vacuum Oven with Pump

Failure PhenomenaPossible ReasonsTreatment
No power

The out power socket had no power.Check whether the lines are connected well and whether the socket is well.
The power plug is not inserted well in the socket or the line is cut off.Re-insert the plug or repair the line.
The fuse is broken or there is no fuse.Check whether there is any short
circuit.
Replace the fuse (short circuit for apparatus power transformer, short circuit for heater, short circuit for grounding and others short circuit all can cause breaking of fuse.
The temperature does not increaseThe set value is too low.Set temperature SV≥RT+10℃ (RT is environment temperature).
The heater is damaged (short circuit, or open circuit)Replace it.
Use timing function or the setting is not correct.ST=0 or ST=(heating time + constant temperature time.
The cabinet cannot be vacuumized.The vacuum pump is not of the correct model and size.The vacuumizing speed should not be less than 2 L/S.
Various connecting pipe is too loose.Replace it.
The door is not closed well.Adjust the door pin distance.
Product reviews
A Perfect industrial/lab vacuum oven
5
Jackson
Avatar
3/15/2022 2:11 AM
This vacuum oven is what we want. We have bought it for a long time and there is no trouble about the product. The operation is smooth and the quality is good. It is really worth to have a try.
Was this review helpful? Yes No (0/0)
Well-built and durable piece of equipment
5
Osborn
Avatar
2/17/2023 1:21 AM
The interior chamber of this oven is large, I have ample space for samples of various sizes. It's great. And the vacuum pump that comes with the oven is also very powerful and has no trouble achieving the desired vacuum levels quickly. Satisfied purchase!
Was this review helpful? Yes No (0/0)
It's pretty good
4
Leon
Avatar
10/9/2025 9:01 PM
Great little vacuum oven for our lab. The 8L size is perfect for our daily R
Was this review helpful? Yes No (0/0)
Vacuum accuracy
5
Linde
Avatar
3/3/2026 8:21 PM
What is the vacuum accuracy of the ATO-DZF-6010 vacuum oven? Can you provide the product specifications?
Was this review helpful? Yes No (0/0)
ATO Responded
The limit of this vacuum gauge is -0.1 MPa; vacuum accuracy parameters are not currently available.
Only registered users can write reviews