Tetrahydrothiophene (THT) Gas Sensor, 0-50ppm

$209.99
Discounted tetrahydrothiophene (THT) gas sensor for sale at a low price, with a 0-50 ppm measuring range. The THT gas sensor has 0-50ppm measuring rang, 0.5ppm resolution, ±10% precision. It can be used in air quality testing, industrial robots, chemical plants, coal mines, instrumentation, underground pipelines, security workshops, fire emergencies and so on.
SKU: ATO-GS-THT
Free Shipping
Delivery date: 8-12 days

Low-cost THT gas sensor with a 0-50 ppm range, 0.5 ppm resolution, and ±10% precision. Suitable for air quality testing, industrial robots, chemical plants, coal mines, pipelines, and fire safety.

Specification

ModelATO-S4THT-50
Detection PrincipleElectrochemical Three-Electrode
Detected GasTetrahydrothiophene (C4H8S)
Detection Range0-50 ppm
Maximum Load Concentration100 ppm
Sensitivity150 ±100 nA/ppm
Zero Drift0-1 ppm
Resolution0.5 ppm
Response Time≤40s
Bias Voltage0 mV
Load Resistance5-30Ω
Temperature Range-30°C to 50°C
Humidity Range15%RH to 90%RH (Non-condensing)
Repeatability<±2%
Long-term Stability<2% Signal/Month
LinearityLinear
Operating Pressure90 to 110 kPa
Warranty12 months after delivery


Dimension (Unit: mm)

Electrochemical gas sensors size

Crossover Interference

The chlorine dioxide (ClO2) gas sensor also responds to gases other than the target gas. For reference, the response characteristics of the sensor to several common interfering gases are listed in the table below. The data in the table are typical responses of interfering gases at a given concentration.

Interfering GasGas Concentration (PPM)Displayed Value (mg/m³ THT)
CO500-3
H₂S258
N₂100%0
NO₂2335
CO₂10000
H₂20000


Basic Test Circuit

Gas sensor basic test circuit

Application

Tetrahydrothiophene (THT) gas sensor can be used in air quality testing, industrial robots, chemical plants, coal mines, instrumentation underground piping, security workshops, fire emergency and so on.

Electrochemical gas sensor applications

Tips: Why is THT detection important for safety?

Since THT is used as an odorant in natural gas, its presence indicates a gas leak. If THT levels drop too low, gas leaks may go undetected, leading to explosion risks, suffocation hazards, and environmental contamination. A THT gas sensor ensures that:

  • Leaks are detected early, before reaching dangerous levels.
  • Proper odorant levels are maintained in gas distribution systems.
  • Industrial plants and refineries comply with safety regulations.
Product reviews
Reliable gas sensor
5
Jeremy
Avatar
9/3/2026 7:16 PM
Used this THT gas sensor as part of an industrial gas monitoring setup. The specifications matched our requirements, especially the 0–50 ppm range and 0.5 ppm resolution. After calibration and testing, the sensor provided stable readings. The integration process was straightforward for our engineering team.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Low-cost THT gas sensor with a 0-50 ppm range, 0.5 ppm resolution, and ±10% precision. Suitable for air quality testing, industrial robots, chemical plants, coal mines, pipelines, and fire safety.

Specification

ModelATO-S4THT-50
Detection PrincipleElectrochemical Three-Electrode
Detected GasTetrahydrothiophene (C4H8S)
Detection Range0-50 ppm
Maximum Load Concentration100 ppm
Sensitivity150 ±100 nA/ppm
Zero Drift0-1 ppm
Resolution0.5 ppm
Response Time≤40s
Bias Voltage0 mV
Load Resistance5-30Ω
Temperature Range-30°C to 50°C
Humidity Range15%RH to 90%RH (Non-condensing)
Repeatability<±2%
Long-term Stability<2% Signal/Month
LinearityLinear
Operating Pressure90 to 110 kPa
Warranty12 months after delivery


Dimension (Unit: mm)

Electrochemical gas sensors size

Crossover Interference

The chlorine dioxide (ClO2) gas sensor also responds to gases other than the target gas. For reference, the response characteristics of the sensor to several common interfering gases are listed in the table below. The data in the table are typical responses of interfering gases at a given concentration.

Interfering GasGas Concentration (PPM)Displayed Value (mg/m³ THT)
CO500-3
H₂S258
N₂100%0
NO₂2335
CO₂10000
H₂20000


Basic Test Circuit

Gas sensor basic test circuit

Application

Tetrahydrothiophene (THT) gas sensor can be used in air quality testing, industrial robots, chemical plants, coal mines, instrumentation underground piping, security workshops, fire emergency and so on.

Electrochemical gas sensor applications

Tips: Why is THT detection important for safety?

Since THT is used as an odorant in natural gas, its presence indicates a gas leak. If THT levels drop too low, gas leaks may go undetected, leading to explosion risks, suffocation hazards, and environmental contamination. A THT gas sensor ensures that:

  • Leaks are detected early, before reaching dangerous levels.
  • Proper odorant levels are maintained in gas distribution systems.
  • Industrial plants and refineries comply with safety regulations.
Product reviews
Reliable gas sensor
5
Jeremy
Avatar
9/3/2026 7:16 PM
Used this THT gas sensor as part of an industrial gas monitoring setup. The specifications matched our requirements, especially the 0–50 ppm range and 0.5 ppm resolution. After calibration and testing, the sensor provided stable readings. The integration process was straightforward for our engineering team.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews