Smoke & Gas Detector with Digital Display, Combustible Gas Alarm

$53.85
Factory price smoke and gas detector for sale online, equipped with a clear LCD display, capable of monitoring smoke and combustible gases such as natural gas and liquefied gas. Its alarm sound is up to 90 decibels and supports AC90~240V power input.
SKU: ATO-SD-SR902-2
*
*
Free Shipping
Delivery date: 6-12 days

The wall-mounted smoke gas detector is designed for reliable detection of gas leaks. Advanced semiconductor sensor is adopted to ensure high stability and long life. The smoke alarm is suitable for the safety of residential house, villas, hotels, markets, boarding house etc.

Features

  • The smoke gas detector utilizes a high-reliability sensor to ensure accurate and dependable gas leak detection.
  • It automatically resets after an alarm to provide continuous monitoring without manual intervention.
  • MCU processing technology is adopted for enhanced performance and control.
  • The detector includes an auto-detection feature for sensor failure to maintain operational integrity.
  • It is designed to detect both natural gas and LPG (liquefied petroleum gas) for versatile safety applications.
  • The gas alarm features SMT (Surface Mount Technology) design for improved stability and reliability.

Specification

  • Model: ATO-SR-902-2
  • Operating Voltage: AC90~240V
  • Static Power Consumption: ≤1.3W (220V)
  • Alarm Power Consumption: ≤1.7W (220V)
  • Warm-up Time: About 180 seconds
  • Alarm Level: 8%LEL (±3%) or 4000ppm (±1500ppm)
  • Response Time: ≤10 seconds
  • Recovery Time: ≤30 seconds
  • Alarm Indicator: red LED (or LCD display)
  • Sound Level: ≥85dB/m
  • Operating Temperature: -10℃~+50℃ (Indoor temperature)
  • Humidity: ≤95%RH (No condensation)
  • Working Atmospheric Pressure: 800hPa~1100hPa
  • Installation Mode: Wall mounted
  • Alarm Output: Sound & flash alarm/relay output (12 volt pulse voltage)
  • Outline Size: 100*60*30mm
  • Wight: 230g
  • Certification: CE, ROHS, EN50194

Dimension (mm)

Smoke gas detector digital display dimension

LED Information

Red LED FlashGas Leaking
Yellow LED OnSensor Failure
Green LED OnNormal Working
Green LED FlashWarm-up Inside Sensor


Details

Smoke gas detector digital display detail

Tips: Precautions for installation of smoke and gas detector

  • Installation location: Wall-mounted within 1 meter from the ceiling, no more than 4 meters in height, and no more than 4 meters away from the gas.
  • Installation height: Since the POM of the gas is lighter than air, it will rise when the gas leaks. Therefore, when installing the detector, it is generally installed in a higher place, but not too far from the gas source, within 2-4 meters is appropriate, and the radius is about 1.5 meters from the gas source.
  • Installation environment: When installing at home, it should be noted that the installation location should not be too close to the gas stove to prevent the detector from being baked by the stove flame, thereby affecting the detector's sensitivity.
Product reviews
Measuring smoke volume inside a barbecue oven
5
Arro
Avatar
10/28/2026 12:59 AM
Hello, I'm looking for a solution to quantify the amount of smoke inside a barbecue oven. Extremely high scientific rigor or precision isn't required; the primary application is A/B testing, such as determining whether a change made resulted in more or less smoke.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we cannot provide detectors for direct smoke measurement inside the barbecue oven due to the high temperature. We can only provide smoke detectors for indoor and outdoor installation.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The wall-mounted smoke gas detector is designed for reliable detection of gas leaks. Advanced semiconductor sensor is adopted to ensure high stability and long life. The smoke alarm is suitable for the safety of residential house, villas, hotels, markets, boarding house etc.

Features

  • The smoke gas detector utilizes a high-reliability sensor to ensure accurate and dependable gas leak detection.
  • It automatically resets after an alarm to provide continuous monitoring without manual intervention.
  • MCU processing technology is adopted for enhanced performance and control.
  • The detector includes an auto-detection feature for sensor failure to maintain operational integrity.
  • It is designed to detect both natural gas and LPG (liquefied petroleum gas) for versatile safety applications.
  • The gas alarm features SMT (Surface Mount Technology) design for improved stability and reliability.

Specification

  • Model: ATO-SR-902-2
  • Operating Voltage: AC90~240V
  • Static Power Consumption: ≤1.3W (220V)
  • Alarm Power Consumption: ≤1.7W (220V)
  • Warm-up Time: About 180 seconds
  • Alarm Level: 8%LEL (±3%) or 4000ppm (±1500ppm)
  • Response Time: ≤10 seconds
  • Recovery Time: ≤30 seconds
  • Alarm Indicator: red LED (or LCD display)
  • Sound Level: ≥85dB/m
  • Operating Temperature: -10℃~+50℃ (Indoor temperature)
  • Humidity: ≤95%RH (No condensation)
  • Working Atmospheric Pressure: 800hPa~1100hPa
  • Installation Mode: Wall mounted
  • Alarm Output: Sound & flash alarm/relay output (12 volt pulse voltage)
  • Outline Size: 100*60*30mm
  • Wight: 230g
  • Certification: CE, ROHS, EN50194

Dimension (mm)

Smoke gas detector digital display dimension

LED Information

Red LED FlashGas Leaking
Yellow LED OnSensor Failure
Green LED OnNormal Working
Green LED FlashWarm-up Inside Sensor


Details

Smoke gas detector digital display detail

Tips: Precautions for installation of smoke and gas detector

  • Installation location: Wall-mounted within 1 meter from the ceiling, no more than 4 meters in height, and no more than 4 meters away from the gas.
  • Installation height: Since the POM of the gas is lighter than air, it will rise when the gas leaks. Therefore, when installing the detector, it is generally installed in a higher place, but not too far from the gas source, within 2-4 meters is appropriate, and the radius is about 1.5 meters from the gas source.
  • Installation environment: When installing at home, it should be noted that the installation location should not be too close to the gas stove to prevent the detector from being baked by the stove flame, thereby affecting the detector's sensitivity.
Product reviews
Measuring smoke volume inside a barbecue oven
5
Arro
Avatar
10/28/2026 12:59 AM
Hello, I'm looking for a solution to quantify the amount of smoke inside a barbecue oven. Extremely high scientific rigor or precision isn't required; the primary application is A/B testing, such as determining whether a change made resulted in more or less smoke.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we cannot provide detectors for direct smoke measurement inside the barbecue oven due to the high temperature. We can only provide smoke detectors for indoor and outdoor installation.
Only registered users can write reviews