Sanitary Pressure Transducer for Food Safety/Healthcare

$322.69
Sanitary pressure transducer offers selectable ranges from 0.1 to 4 MPa with 4–20mA, voltage or RS485 output options. Designed for sanitary process pressure measurement, it is suitable for food processing, healthcare and other applications with higher hygiene requirements.
SKU: ATO-PRES-Z66E
*
*
Free Shipping
Delivery date: 6-12 days

High-precision sanitary pressure transmitter for sale, this model is constructed of precision stainless steel 316L material with silicone and Nitrile rubber seals to ensure its long-term durability in harsh environments. The pressure type is gauge pressure and supports multiple signal outputs. The pressure transmitter is vibration resistant up to 10g (20-2000Hz) and shock resistant up to 500g/ms, providing stable output in high-vibration environments. Its electrical protection is complete, including permanent short-circuit protection and reverse polarity protection functions, ensuring that the device remains safe and reliable in the event of electrical abnormalities.

Specification

ModelATO-CYZ66E
Measuring MediumLiquid, gas (compatible with contact material)
Pressure Range0.1~0~4MPa (optional)
Pressure TypeGauge pressure
Power SupplyRS485/4-20mA/0~5VDC/1~5VDC0~10VDC
9~36VDC15~36VDC
Signal OutputRS485/4-20mA/0~5VDC/1~5VDC/0~10VDC (optional)
Response FrequencyRS485 (50Hz)Others (30Hz)
Accuracy ClassRange ≥100kPa10kPa≤range<100kPa
0.25%FS0.5%FS
Connection MethodUpper range ≥0.6MPaUpper range ≤10MPa
G1/2G1
Medium Temperature-40~85°C
Response Time20ms
Stability±0.1% FS/year
Temperature Compensation-10~70°C
Temperature Drift±0.01% FS/°C (within temperature compensation range)
±0.05% FS/°C (outside temperature compensation range)
Protection ClassIP69K (to be achieved with complete electrical connection)
ResolutionAnalog output ±0.01%FS, digital output ±0.05%FS
Diaphragm316L stainless steel
Process Connection316L stainless steel
Housings316L stainless steel
O-RingSilicone rubber
E-ringNitrile rubber
Vibration Resistance10g (20-2000Hz)
Shock Resistance500g/ms
Short Circuit ProtectionPermanent
Reverse Polarity ProtectionNo damage, but not working
Insulation Resistance≥100MΩ 500VDC
Dielectric Strength500VAC
Ambient Temperature-40~85°C
Ambient Humidity0%~95%RH (no condensation and no dew)
Durability1*106 cycles (lower range to upper range cycle count)
Net Weight≈270g


Features

  • Excellent Protection: High protection level of IP69K, strong waterproof and dustproof ability, suitable for long-term stable operation in extreme environments.
  • Intelligent Chip Integration: Built-in integrated chip supports wide range of voltage power supply and strong adaptability, ensuring reliable power supply for equipment.
  • Compact and Convenient: Compact design, easy to clean and simple to install, suitable for space-constrained scenarios.
  • Highly Effective Anti-Interference: Adopting frequency cut-off design, it has strong anti-interference ability and lightning strike prevention function to ensure the stability of data transmission.
  • Comprehensive Circuit Protection: Current limiting, voltage limiting and reverse connection protection functions increase the safety and durability of the equipment.
  • High Accuracy and Fast Response: High measurement accuracy, good stability and fast response speed, suitable for application scenarios with high requirements for real-time data.

Pressure Sensor Dimension Drawing (unit: mm)

Sanitary pressure transducer size

Wiring Diagram

Sanitary pressure transducer wiring diagram

Note:

Circles represent shielded wires, and all marked grounding points must be effectively grounded. It is recommended to use shielded twisted signal cable. In order to avoid ground loops, the shielding layer uses a single-ended ground, in the pressure transmitter end of the insulation floating ground, and in the control terminal ground.

The transmitter shell is grounded by default, so the field equipment needs to be effectively grounded, if the field equipment can not be grounded, it is necessary to make the indicated grounding point effectively grounded.

Applications

Sanitary pressure transducer applicationTips: How to install the sanitary pressure sensor correctly?

Before installation, make sure that the connecting parts and piping are clean and free of contamination to avoid contaminants that could affect the measurement accuracy. When installing the sensor, use sanitary fittings (e.g. Tri-Clamp, DIN, or welded) to connect the sensor and make sure that the seals are properly installed to prevent leakage. Avoid excessive torque or mechanical shock to the sensor to prevent damage to the internal components. After installation, calibration is recommended to ensure accurate measurements.

The sanitary pressure sensors are designed to be maintenance free, suitable for multiple cleaning and sterilization and have a long service life. It is recommended that the sensor's housing and seals be checked regularly for integrity to avoid leakage or measurement errors due to wear or deterioration. The sensors have no internal mechanical parts and are not susceptible to wear and tear and can usually operate stably for several years. To ensure long-term accuracy, calibration and performance checks can be performed annually.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High-precision sanitary pressure transmitter for sale, this model is constructed of precision stainless steel 316L material with silicone and Nitrile rubber seals to ensure its long-term durability in harsh environments. The pressure type is gauge pressure and supports multiple signal outputs. The pressure transmitter is vibration resistant up to 10g (20-2000Hz) and shock resistant up to 500g/ms, providing stable output in high-vibration environments. Its electrical protection is complete, including permanent short-circuit protection and reverse polarity protection functions, ensuring that the device remains safe and reliable in the event of electrical abnormalities.

Specification

ModelATO-CYZ66E
Measuring MediumLiquid, gas (compatible with contact material)
Pressure Range0.1~0~4MPa (optional)
Pressure TypeGauge pressure
Power SupplyRS485/4-20mA/0~5VDC/1~5VDC0~10VDC
9~36VDC15~36VDC
Signal OutputRS485/4-20mA/0~5VDC/1~5VDC/0~10VDC (optional)
Response FrequencyRS485 (50Hz)Others (30Hz)
Accuracy ClassRange ≥100kPa10kPa≤range<100kPa
0.25%FS0.5%FS
Connection MethodUpper range ≥0.6MPaUpper range ≤10MPa
G1/2G1
Medium Temperature-40~85°C
Response Time20ms
Stability±0.1% FS/year
Temperature Compensation-10~70°C
Temperature Drift±0.01% FS/°C (within temperature compensation range)
±0.05% FS/°C (outside temperature compensation range)
Protection ClassIP69K (to be achieved with complete electrical connection)
ResolutionAnalog output ±0.01%FS, digital output ±0.05%FS
Diaphragm316L stainless steel
Process Connection316L stainless steel
Housings316L stainless steel
O-RingSilicone rubber
E-ringNitrile rubber
Vibration Resistance10g (20-2000Hz)
Shock Resistance500g/ms
Short Circuit ProtectionPermanent
Reverse Polarity ProtectionNo damage, but not working
Insulation Resistance≥100MΩ 500VDC
Dielectric Strength500VAC
Ambient Temperature-40~85°C
Ambient Humidity0%~95%RH (no condensation and no dew)
Durability1*106 cycles (lower range to upper range cycle count)
Net Weight≈270g


Features

  • Excellent Protection: High protection level of IP69K, strong waterproof and dustproof ability, suitable for long-term stable operation in extreme environments.
  • Intelligent Chip Integration: Built-in integrated chip supports wide range of voltage power supply and strong adaptability, ensuring reliable power supply for equipment.
  • Compact and Convenient: Compact design, easy to clean and simple to install, suitable for space-constrained scenarios.
  • Highly Effective Anti-Interference: Adopting frequency cut-off design, it has strong anti-interference ability and lightning strike prevention function to ensure the stability of data transmission.
  • Comprehensive Circuit Protection: Current limiting, voltage limiting and reverse connection protection functions increase the safety and durability of the equipment.
  • High Accuracy and Fast Response: High measurement accuracy, good stability and fast response speed, suitable for application scenarios with high requirements for real-time data.

Pressure Sensor Dimension Drawing (unit: mm)

Sanitary pressure transducer size

Wiring Diagram

Sanitary pressure transducer wiring diagram

Note:

Circles represent shielded wires, and all marked grounding points must be effectively grounded. It is recommended to use shielded twisted signal cable. In order to avoid ground loops, the shielding layer uses a single-ended ground, in the pressure transmitter end of the insulation floating ground, and in the control terminal ground.

The transmitter shell is grounded by default, so the field equipment needs to be effectively grounded, if the field equipment can not be grounded, it is necessary to make the indicated grounding point effectively grounded.

Applications

Sanitary pressure transducer applicationTips: How to install the sanitary pressure sensor correctly?

Before installation, make sure that the connecting parts and piping are clean and free of contamination to avoid contaminants that could affect the measurement accuracy. When installing the sensor, use sanitary fittings (e.g. Tri-Clamp, DIN, or welded) to connect the sensor and make sure that the seals are properly installed to prevent leakage. Avoid excessive torque or mechanical shock to the sensor to prevent damage to the internal components. After installation, calibration is recommended to ensure accurate measurements.

The sanitary pressure sensors are designed to be maintenance free, suitable for multiple cleaning and sterilization and have a long service life. It is recommended that the sensor's housing and seals be checked regularly for integrity to avoid leakage or measurement errors due to wear or deterioration. The sensors have no internal mechanical parts and are not susceptible to wear and tear and can usually operate stably for several years. To ensure long-term accuracy, calibration and performance checks can be performed annually.