Roots Gas Flow Meter, DN25-DN150

$2,366.93
The Roots gas flow meter, which is designed to provide a low cost and high efficiency solution for all kinds of industrial gas measurement. Adopt aluminum alloy shell, support 1.6MPa pressure environment, measuring range up to 1000m³/h, optional DN25-DN150 nominal diameter, support a variety of signal output (4-20mA or RS485), suitable for intelligent monitoring system.
SKU: ATO-FLOW-MKLQ
*
*
Free Shipping
Delivery date: 6-12 days

Intelligent Roots gas flow meter is a type of gas flow meter which integrates flow, temperature, pressure sensor and intelligent instrument, and can measure natural gas, city gas, propane, nitrogen and other gases, the caliber of DN25-DN150 is available in stock, and it supports 4-20mA and RS485 output signals, which is highly compatible. Gas flowmeter adopts aluminum alloy tube body, pressure resistance up to 1.6MPa, suitable for a variety of working conditions.

Specification

ModelATO-MKLQ-01
Nominal DiameterDN25-DN150
Flow Range1~1000m³/h
Accuracy1.5%
Signal Output4-20mA/RS485 optional
Pressure Rating1.6MPa
Measuring MediaNatural gas, city gas, propane, nitrogen, industrial inert gas and other non-corrosive gases
Standard ConditionsP=101.325 kPa, T=293.15K
Ambient Temperature-25℃~+80℃
Relative Humidity5%RH-95%RH
Medium Temperature-20℃~+60℃
Atmospheric Pressure86kPa~106kPa
Operating Pressure≦400kPa, note: Roots flow meter operating pressure should not be greater than 400kPa, otherwise it will cause air leakage phenomenon.
Internal Instrument Power Supply1 section 3.6VDC lithium battery, battery voltage in 3.1V~3.6V can work normally
Internal GPRS Power Supply1 6.0VDC lithium battery, battery voltage in 5.0V~6.6V can work normally.
External Utility Power Supply±24VDC±15%, ripple≤±5%, suitable for 4~20mA output, RS485
External Utility (Solar) GPRS Power Supply+5VDC~+7VDC
Overall Power ConsumptionExternal power supply: <1W
Internal instrument power supply: Average power consumption ≤1mW, can work continuously for more than five years
Internal GPRS power supply: According to the average daily communication times (2-12 times), it can work continuously for one to five years.
Pipe MaterialAluminum alloy


Flow Meter Flow Range

Nominal DiameterFlow RangeMounting HeightNominal Pressure
DN251~25m³/h128mm1.6MPa
DN401~40m³/h128mm
DN502~100m³/h192mm
DN803~250m³/h245mm
DN1004~650m³/h245mm
DN15015~1000m³/h460mm


Feature

Roots gas flow meter feature

  1. Wide-screen LCD display, interface design is reasonable, query data is more clear and intuitive, with key operation is more convenient.
  2. Roots gas flow meter choose high quality wiring board, wiring is more solid, signal transmission is more stable, optional built-in battery power supply, dual power supply is more insurance, can cope with unexpected situations.
  3. Aluminum alloy material flowmeter body, integrated sensor overall anti-interference, high temperature resistance, signal transmission is more stable.

Dimension (unit: mm)

Roots gas flow meter dimension

Nominal DiameterACWHC1n-dNet Weight
DN2523590105145∅854-M127kg
DN40307120105145∅1104-M1610kg
DN50420156185170∅1254-M1618kg
DN80460175185170∅1608-M1628kg
DN100565230235250∅1808-M1645kg
DN150640293450460∅2408-M20145kg


Working Principle

Roots gas flow meter working principle

Intelligent roots gas flow meter, mainly consists of shell, conjugate rotor and intelligent flow totalizer and other components. A pair of conjugate rotors installed in the metering chamber keeps the rotors in the correct relative position by means of precision-machined adjusting gears under the action of the pressure difference between the inlet and outlet of the circulating gas (Pin > Pout).

Optimum working gaps are maintained between the rotors, between the rotors and the housing, and between the rotors and the wall plate, realizing a continuous contactless seal. For every one-week rotation of the rotor, four times the effective volume of the metering chamber is output. The metering process and working principle are shown in the diagram (only a quarter of the cycle is shown in the diagram).

Application

Roots gas flow meter applications

Tips: Installation of Roots gas flow meter

Before installing the flowmeter should be removed from the import and export encapsulation, must prevent particulate impurities fall into the measurement chamber, such as the measurement chamber surface coated with antirust oil, can be flushed with gasoline or kerosene, and rigorously remove impurities from the pipeline.

Roots flow meter should be installed upstream of the filter or strainer to prevent rust slag, welding slag and other impurities into the measurement chamber.

When installing the flowmeter, no matter the import and export is vertical or horizontal position, should try to keep the rotor axis horizontal.

In order to prevent the new installation of the pipeline rust slag, welding slag and other impurities into the gas flowmeter, the user should first install the transition pipe in the installation position of the flowmeter, ventilated for a period of time (about a week), to ensure that there are no large particles of impurities, and then replace the flowmeter.

Installation of the flow meter, should ensure that the center of the flowmeter and the center of the pipeline alignment, no misalignment, and so that the flowmeter is not affected by external forces (including axial and tangential).

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Intelligent Roots gas flow meter is a type of gas flow meter which integrates flow, temperature, pressure sensor and intelligent instrument, and can measure natural gas, city gas, propane, nitrogen and other gases, the caliber of DN25-DN150 is available in stock, and it supports 4-20mA and RS485 output signals, which is highly compatible. Gas flowmeter adopts aluminum alloy tube body, pressure resistance up to 1.6MPa, suitable for a variety of working conditions.

Specification

ModelATO-MKLQ-01
Nominal DiameterDN25-DN150
Flow Range1~1000m³/h
Accuracy1.5%
Signal Output4-20mA/RS485 optional
Pressure Rating1.6MPa
Measuring MediaNatural gas, city gas, propane, nitrogen, industrial inert gas and other non-corrosive gases
Standard ConditionsP=101.325 kPa, T=293.15K
Ambient Temperature-25℃~+80℃
Relative Humidity5%RH-95%RH
Medium Temperature-20℃~+60℃
Atmospheric Pressure86kPa~106kPa
Operating Pressure≦400kPa, note: Roots flow meter operating pressure should not be greater than 400kPa, otherwise it will cause air leakage phenomenon.
Internal Instrument Power Supply1 section 3.6VDC lithium battery, battery voltage in 3.1V~3.6V can work normally
Internal GPRS Power Supply1 6.0VDC lithium battery, battery voltage in 5.0V~6.6V can work normally.
External Utility Power Supply±24VDC±15%, ripple≤±5%, suitable for 4~20mA output, RS485
External Utility (Solar) GPRS Power Supply+5VDC~+7VDC
Overall Power ConsumptionExternal power supply: <1W
Internal instrument power supply: Average power consumption ≤1mW, can work continuously for more than five years
Internal GPRS power supply: According to the average daily communication times (2-12 times), it can work continuously for one to five years.
Pipe MaterialAluminum alloy


Flow Meter Flow Range

Nominal DiameterFlow RangeMounting HeightNominal Pressure
DN251~25m³/h128mm1.6MPa
DN401~40m³/h128mm
DN502~100m³/h192mm
DN803~250m³/h245mm
DN1004~650m³/h245mm
DN15015~1000m³/h460mm


Feature

Roots gas flow meter feature

  1. Wide-screen LCD display, interface design is reasonable, query data is more clear and intuitive, with key operation is more convenient.
  2. Roots gas flow meter choose high quality wiring board, wiring is more solid, signal transmission is more stable, optional built-in battery power supply, dual power supply is more insurance, can cope with unexpected situations.
  3. Aluminum alloy material flowmeter body, integrated sensor overall anti-interference, high temperature resistance, signal transmission is more stable.

Dimension (unit: mm)

Roots gas flow meter dimension

Nominal DiameterACWHC1n-dNet Weight
DN2523590105145∅854-M127kg
DN40307120105145∅1104-M1610kg
DN50420156185170∅1254-M1618kg
DN80460175185170∅1608-M1628kg
DN100565230235250∅1808-M1645kg
DN150640293450460∅2408-M20145kg


Working Principle

Roots gas flow meter working principle

Intelligent roots gas flow meter, mainly consists of shell, conjugate rotor and intelligent flow totalizer and other components. A pair of conjugate rotors installed in the metering chamber keeps the rotors in the correct relative position by means of precision-machined adjusting gears under the action of the pressure difference between the inlet and outlet of the circulating gas (Pin > Pout).

Optimum working gaps are maintained between the rotors, between the rotors and the housing, and between the rotors and the wall plate, realizing a continuous contactless seal. For every one-week rotation of the rotor, four times the effective volume of the metering chamber is output. The metering process and working principle are shown in the diagram (only a quarter of the cycle is shown in the diagram).

Application

Roots gas flow meter applications

Tips: Installation of Roots gas flow meter

Before installing the flowmeter should be removed from the import and export encapsulation, must prevent particulate impurities fall into the measurement chamber, such as the measurement chamber surface coated with antirust oil, can be flushed with gasoline or kerosene, and rigorously remove impurities from the pipeline.

Roots flow meter should be installed upstream of the filter or strainer to prevent rust slag, welding slag and other impurities into the measurement chamber.

When installing the flowmeter, no matter the import and export is vertical or horizontal position, should try to keep the rotor axis horizontal.

In order to prevent the new installation of the pipeline rust slag, welding slag and other impurities into the gas flowmeter, the user should first install the transition pipe in the installation position of the flowmeter, ventilated for a period of time (about a week), to ensure that there are no large particles of impurities, and then replace the flowmeter.

Installation of the flow meter, should ensure that the center of the flowmeter and the center of the pipeline alignment, no misalignment, and so that the flowmeter is not affected by external forces (including axial and tangential).

Only registered users can write reviews
Customers who bought this item also bought

3 inch Flanged Y Strainer

ATO-FYS-80
$450.54
3 inch (DN80) stainless steel flanged Y strainer features PN16 working pressure, SS 304/316 material, and flange connection, used for various industrial applications, such as chemical processing, oil and gas, water treatment, and food processing.