DNIR Refrigerant A2L R454B Gas Sensor, 0-100%LFL

$190.24
This advanced NDIR refrigerant gas sensor is designed for precise and reliable detection of R454B (an A2L-class hydrofluoroolefin) at concentrations ranging from 0 to 100% LFL. It utilizes non-dispersive infrared (NDIR) technology, ensuring high accuracy, excellent linearity, and long-term stability without drift.It's ideally suited for leak detection in HVAC/R systems, industrial refrigeration, and safety monitoring applications.
SKU: ATO-GS-R454B
Free Shipping
Delivery date: 6-12 days

This industrial-grade infrared gas sensor leverages advanced NDIR (Non-Dispersive Infrared) technology for the specific detection of R454B refrigerant gas. It offers a robust and maintenance-free solution for monitoring A2L refrigerants, characterized by high precision, stability, and resilience in challenging environments. The sensor's compact and pump-free design simplifies integration, while its dual-channel measurement and temperature compensation ensure reliable performance.

Specification

ModelATO-FS4NDIR/R454B
Detection GasR454B (Hydrofluoroolefin)
Detection PrincipleNon-Dispersive Infrared (NDIR)
Detection Range0 - 100% LFL (100% LFL = 11.49% Vol)
Resolution1% LFL
Accuracy±3.75% LFL
Response Time (T90)≤ 30 seconds
Power SupplyDC 3.6 V ~ 5.0 V
Operating Current≤ 85 mA (@ 5V)
Output InterfaceModbus (Default) / DAC (0.4V~2V, reserved)
Operating Temperature-20 ℃ ~ +60 ℃
Operating Humidity0 ~ 95% RH (Non-condensing)
Lifespan10 years


Feature

  • The NDIR refrigerant R454B gas sensor utilizes the proven NDIR principle for specific and stable gas detection.
  • This refrigerant sensor features a compact, pump-free design requiring no internal tubing, simplifying installation.
  • With its dual-channel design, the R454B gas sensor delivers high accuracy and excellent linear output with minimal drift.
  • The best NDIR sensor boasts strong resistance to water vapor interference and gas poisoning, ensuring long-term reliability.
  • Designed for durability, this gas sensor detector incorporates temperature compensation and offers a long operational lifespan.

Dimension (Unit: mm)

refrigerant r454b gas sensor dimension

Working Principle

refrigerant r454b gas sensor working principle

Application

refrigerant r454b gas sensor application

5 Tips for DNIR Refrigerant A2L R454B Gas Sensor

  • Ensure the gas detector sensor is installed in a location representative of the potential leak source and where air circulation is adequate for detection.
  • The specified accuracy is valid within the standard pressure range of 75 kPa to 120 kPa; significant pressure deviations may affect readings.
  • While highly resistant, avoid prolonged exposure to condensing humidity or direct water spray to maintain the good gas sensor integrity.
  • For optimal performance and longevity, adhere to the specified operating voltage and temperature ranges.
  • Regular functional checks are recommended to verify sensor performance, especially before critical operations.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

This industrial-grade infrared gas sensor leverages advanced NDIR (Non-Dispersive Infrared) technology for the specific detection of R454B refrigerant gas. It offers a robust and maintenance-free solution for monitoring A2L refrigerants, characterized by high precision, stability, and resilience in challenging environments. The sensor's compact and pump-free design simplifies integration, while its dual-channel measurement and temperature compensation ensure reliable performance.

Specification

ModelATO-FS4NDIR/R454B
Detection GasR454B (Hydrofluoroolefin)
Detection PrincipleNon-Dispersive Infrared (NDIR)
Detection Range0 - 100% LFL (100% LFL = 11.49% Vol)
Resolution1% LFL
Accuracy±3.75% LFL
Response Time (T90)≤ 30 seconds
Power SupplyDC 3.6 V ~ 5.0 V
Operating Current≤ 85 mA (@ 5V)
Output InterfaceModbus (Default) / DAC (0.4V~2V, reserved)
Operating Temperature-20 ℃ ~ +60 ℃
Operating Humidity0 ~ 95% RH (Non-condensing)
Lifespan10 years


Feature

  • The NDIR refrigerant R454B gas sensor utilizes the proven NDIR principle for specific and stable gas detection.
  • This refrigerant sensor features a compact, pump-free design requiring no internal tubing, simplifying installation.
  • With its dual-channel design, the R454B gas sensor delivers high accuracy and excellent linear output with minimal drift.
  • The best NDIR sensor boasts strong resistance to water vapor interference and gas poisoning, ensuring long-term reliability.
  • Designed for durability, this gas sensor detector incorporates temperature compensation and offers a long operational lifespan.

Dimension (Unit: mm)

refrigerant r454b gas sensor dimension

Working Principle

refrigerant r454b gas sensor working principle

Application

refrigerant r454b gas sensor application

5 Tips for DNIR Refrigerant A2L R454B Gas Sensor

  • Ensure the gas detector sensor is installed in a location representative of the potential leak source and where air circulation is adequate for detection.
  • The specified accuracy is valid within the standard pressure range of 75 kPa to 120 kPa; significant pressure deviations may affect readings.
  • While highly resistant, avoid prolonged exposure to condensing humidity or direct water spray to maintain the good gas sensor integrity.
  • For optimal performance and longevity, adhere to the specified operating voltage and temperature ranges.
  • Regular functional checks are recommended to verify sensor performance, especially before critical operations.