4 in 1 Portable Particle Counter, PM2.5/PM10

$3,656.98
4-in-1 air particle counter with 2.8" color LCD display, optimized for strong light measurement, easy to read even in bright light. The handheld multifunctional particle counter can quickly and accurately detect PM2.5/PM10 mass concentration, air humidity temperature, formaldehyde content, dew point temperature and wet bulb temperature.
SKU: ATO-PC-98501M
Free Shipping
Delivery date: 6-12 days

Portable air particle counter with 2.8" color LCD screen, simultaneous test display 3 groups of air particles 0.3μm/2.5μm/10μm. 4 in 1 particle counter allows very fast, simple, and accurate measurement of particle concentration, formaldehyde gas concentration, and air humidity temperature.

Specification

ModelATO-DT-98501M
Particle Counting
Particle ChannelPM2.5/PM10
Mass Concentration Range0~2000 μg/m3
Display Resolution1μg/m3
Particle Counting
Particle Channel0.3, 2.5, 10μm
Flow Rate1ft(2.83L/mim) can be controlled by built-in sensor
Calculation Modetotal, differential, concentration
Error5%, 20,000,000 grains/ft3
Air Temperature Measurement
Air Temperature Measurement Range0.5~50C, measurement accuracy of 0.5 °C
Humidity Measurement Range0~100%RH, precision measurement: š2.5%RH (20%~80%RH)
Dew Point Temperature Range-30~100C
Wet Bulb Temperature Range0~80°C
Gas Detection
HCHO Range0.01~5.00ppm, error: ≧5%F.S
CO Range0~1000pppm, error: 5%F.S


Details
Air particle counter details

Features

  • 4-in-1 air particle counter, PM2.5/PM10 mass concentration measurement, air humidity temperature measurement, formaldehyde content detection, dew point temperature and wet bulb temperature detection.
  • 2.8" color LCD display, able to very fast, simple, and accurate measurement of particle concentration, formaldehyde gas concentration, air wet temperature, storage dew point temperature will be on the dry, temperature, and humidity analysis.
  • Strong light measurement optimization, even in bright light can be easily read.
  • The simultaneous test shows 3 groups of air particles 0.3μm/2.5μm/10μm.

Applications

Portable particle counter applications

Tips: What should be noticed when using a dust particle counter

  1. Do not start the counter when the inlet tube is covered or blocked.
  2. The particle counter should be used in a clean environment to prevent damage to the laser sensor.
  3. Do not measure a gas mixture (e.g., hydrogen and oxygen) that may produce a reaction. This gas may also produce an explosion in the counter. Measure these gases need to contact the manufacturer for more information.
  4. Do not sample compressed air without high-pressure decompression equipment (e.g. high pressure diffusers), as all particle counters are designed to operate at one atmosphere.
  5. Water, solutions, or other liquids should not enter the sensor through the inlet tube.
  6. Particle counters are primarily used to test cleanroom clean environments and must be kept at least twelve inches away from the inlet tube when measuring areas with loose particulate material, dust sources, and sprays. In order to avoid the above particles and liquid pollution sensors and pipelines.
  7. When taking samples, avoid taking samples from the counter itself or being contaminated by the gas coming out of the counter.
Product reviews
Useful particle counter for checking different particle sizes
5
Milo
Avatar
9/6/2026 7:13 PM
The ability to view 0.3, 2.5, and 10 μm particle channels is useful for our testing. We can get a better idea of what is happening in the air instead of relying on a single particle measurement. The color display also makes the results easy to check at a glance.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Portable air particle counter with 2.8" color LCD screen, simultaneous test display 3 groups of air particles 0.3μm/2.5μm/10μm. 4 in 1 particle counter allows very fast, simple, and accurate measurement of particle concentration, formaldehyde gas concentration, and air humidity temperature.

Specification

ModelATO-DT-98501M
Particle Counting
Particle ChannelPM2.5/PM10
Mass Concentration Range0~2000 μg/m3
Display Resolution1μg/m3
Particle Counting
Particle Channel0.3, 2.5, 10μm
Flow Rate1ft(2.83L/mim) can be controlled by built-in sensor
Calculation Modetotal, differential, concentration
Error5%, 20,000,000 grains/ft3
Air Temperature Measurement
Air Temperature Measurement Range0.5~50C, measurement accuracy of 0.5 °C
Humidity Measurement Range0~100%RH, precision measurement: š2.5%RH (20%~80%RH)
Dew Point Temperature Range-30~100C
Wet Bulb Temperature Range0~80°C
Gas Detection
HCHO Range0.01~5.00ppm, error: ≧5%F.S
CO Range0~1000pppm, error: 5%F.S


Details
Air particle counter details

Features

  • 4-in-1 air particle counter, PM2.5/PM10 mass concentration measurement, air humidity temperature measurement, formaldehyde content detection, dew point temperature and wet bulb temperature detection.
  • 2.8" color LCD display, able to very fast, simple, and accurate measurement of particle concentration, formaldehyde gas concentration, air wet temperature, storage dew point temperature will be on the dry, temperature, and humidity analysis.
  • Strong light measurement optimization, even in bright light can be easily read.
  • The simultaneous test shows 3 groups of air particles 0.3μm/2.5μm/10μm.

Applications

Portable particle counter applications

Tips: What should be noticed when using a dust particle counter

  1. Do not start the counter when the inlet tube is covered or blocked.
  2. The particle counter should be used in a clean environment to prevent damage to the laser sensor.
  3. Do not measure a gas mixture (e.g., hydrogen and oxygen) that may produce a reaction. This gas may also produce an explosion in the counter. Measure these gases need to contact the manufacturer for more information.
  4. Do not sample compressed air without high-pressure decompression equipment (e.g. high pressure diffusers), as all particle counters are designed to operate at one atmosphere.
  5. Water, solutions, or other liquids should not enter the sensor through the inlet tube.
  6. Particle counters are primarily used to test cleanroom clean environments and must be kept at least twelve inches away from the inlet tube when measuring areas with loose particulate material, dust sources, and sprays. In order to avoid the above particles and liquid pollution sensors and pipelines.
  7. When taking samples, avoid taking samples from the counter itself or being contaminated by the gas coming out of the counter.