Portable Dew Point Meter with Integral Probe

$5,966.19
Portable dew point meter with integral probe, graphic display, easy operation with touch function, USB port, measuring range -80~+50°Ctd, pressure range -1~50 bar, integrated data logger for saving measured values. Dew point measurement instrument can be used to detect residual humidity of compressed air, N2 and O2.
SKU: ATO-DPM-500
*
Free Shipping
Delivery date: 20-30 days

Cheap price portable dew point meter with integral probe, data can be transferred to PC via usb flash drive, quick response, good linearity, stable reading, can touch screen operation.

Specification:

ModelATO-DPM-500
Colour Screen3.5" Touchpanel TFT transmissive, graphics, curves, statistics
InterfacesUSB
Measuring Ranges-80~+50 °Ctd, -20~+70°C, 0~100%RH
Accuracy±0.5 °Ctd (-10~+50°Ctd), typical: ±2°Ctd
Power Supply Unit100~240 VAC, 50~60 Hz, 12VDC~1A
Current SupplyInternal rechargeable Li-Ion batteries charging time approx 4 h
DPM500 operation: approx 12h
Pressure RangeMounting without measuring chamber: -1~50 bar Standard
Mounting with measuring chamber: 2~16 bar
High pressure version up to 350 bar
Response Time T95- 50°Ctd~-10°Ctd<10sec
10°Ctd~-50°Ctd<5 minutes
Humidity Measuresg/m³, mg/m³, ppm V/V, g/kg,°Ctdatm, % Rf
Operating Temperature-20~70°C Measuring gas temperature
0~50°C Ambient temperature
Storage Temperature-20 to +70°C
MaterialPlastic PC/ABS
Dimensions125*96*245mm
Weight550g
CertificateISO 9001:2015

Packing List of Dew Point Meter

NumberNameQuantity
1Portable dew point meter DPM 500 for compressed air and gases1
2Mobile measuring chamber up to 16 bar1
3Diffusion-tight PTFE hose with quick connector, length 1 m1
4Power supply for DPM 500 dew point meter1
5Control and calibration set 11.3 % RH1
6Quick-lock coupling1
7Dry container for dew point sensors1
8Transportation case (small) for DPM 5001

 DetailDew point meter description
What is the dew point?

Dew point temperature (dew point for short) is one of the indicators to measure the water vapor content in a certain gas. Water has the property that it can exist in liquid, solid, or gas under various conditions. To understand the nature of water vapor, we must first know the general nature of the gas. The total pressure (commonly known as the total pressure) produced by any mixed gas is equal to the sum of the partial pressures (partial pressures) of the component gases. This is Dalton's law, which is expressed by formula: Ptotal = P1 + P2 + P3…

The amount of any component gas in the mixed gas can be expressed by pressure. The main components of air are nitrogen, oxygen, and water vapor, so the total atmospheric pressure is composed of the partial pressures of these three gases. The concentration of nitrogen and oxygen is relatively stable, while the concentration of water vapor varies greatly and must be determined by measurement.

The maximum partial pressure of water vapor varies completely with temperature. For example, at 20 ° C (68 ° F), the maximum partial pressure of water vapor is 23.5 mbar. Also called "saturated vapor pressure" at 20 ° C (68 ° F). In a "saturated" environment at 20 ° C (68 ° F), if water vapor continues to increase, liquid water will form. This condensation phenomenon can be used to measure the water vapor content in the gas.

Product reviews
Accurate detection by portable dew point meter
5
Kike
Avatar
12/7/2021 8:29 PM
I like this portable dew point meter very much. I used it to compare the temperature of three rooms and the measured values are more accurate. The measurement time is also relatively short, so there is no need to wait too long.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Cheap price portable dew point meter with integral probe, data can be transferred to PC via usb flash drive, quick response, good linearity, stable reading, can touch screen operation.

Specification:

ModelATO-DPM-500
Colour Screen3.5" Touchpanel TFT transmissive, graphics, curves, statistics
InterfacesUSB
Measuring Ranges-80~+50 °Ctd, -20~+70°C, 0~100%RH
Accuracy±0.5 °Ctd (-10~+50°Ctd), typical: ±2°Ctd
Power Supply Unit100~240 VAC, 50~60 Hz, 12VDC~1A
Current SupplyInternal rechargeable Li-Ion batteries charging time approx 4 h
DPM500 operation: approx 12h
Pressure RangeMounting without measuring chamber: -1~50 bar Standard
Mounting with measuring chamber: 2~16 bar
High pressure version up to 350 bar
Response Time T95- 50°Ctd~-10°Ctd<10sec
10°Ctd~-50°Ctd<5 minutes
Humidity Measuresg/m³, mg/m³, ppm V/V, g/kg,°Ctdatm, % Rf
Operating Temperature-20~70°C Measuring gas temperature
0~50°C Ambient temperature
Storage Temperature-20 to +70°C
MaterialPlastic PC/ABS
Dimensions125*96*245mm
Weight550g
CertificateISO 9001:2015

Packing List of Dew Point Meter

NumberNameQuantity
1Portable dew point meter DPM 500 for compressed air and gases1
2Mobile measuring chamber up to 16 bar1
3Diffusion-tight PTFE hose with quick connector, length 1 m1
4Power supply for DPM 500 dew point meter1
5Control and calibration set 11.3 % RH1
6Quick-lock coupling1
7Dry container for dew point sensors1
8Transportation case (small) for DPM 5001

 DetailDew point meter description
What is the dew point?

Dew point temperature (dew point for short) is one of the indicators to measure the water vapor content in a certain gas. Water has the property that it can exist in liquid, solid, or gas under various conditions. To understand the nature of water vapor, we must first know the general nature of the gas. The total pressure (commonly known as the total pressure) produced by any mixed gas is equal to the sum of the partial pressures (partial pressures) of the component gases. This is Dalton's law, which is expressed by formula: Ptotal = P1 + P2 + P3…

The amount of any component gas in the mixed gas can be expressed by pressure. The main components of air are nitrogen, oxygen, and water vapor, so the total atmospheric pressure is composed of the partial pressures of these three gases. The concentration of nitrogen and oxygen is relatively stable, while the concentration of water vapor varies greatly and must be determined by measurement.

The maximum partial pressure of water vapor varies completely with temperature. For example, at 20 ° C (68 ° F), the maximum partial pressure of water vapor is 23.5 mbar. Also called "saturated vapor pressure" at 20 ° C (68 ° F). In a "saturated" environment at 20 ° C (68 ° F), if water vapor continues to increase, liquid water will form. This condensation phenomenon can be used to measure the water vapor content in the gas.

Product reviews
Accurate detection by portable dew point meter
5
Kike
Avatar
12/7/2021 8:29 PM
I like this portable dew point meter very much. I used it to compare the temperature of three rooms and the measured values are more accurate. The measurement time is also relatively short, so there is no need to wait too long.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews