Pad Mounted Distribution Transformer, 100/200/250/500/1000 kVA

$2,499.00
ATO pad mounted distribution transformers are available in single-phase and three-phase models. Single-phase units feature 25–250 kVA ratings, 7.62–19.92 kV primary voltage, and 120–240 V output. Three-phase models offer 75–2500 kVA capacities with 120/240/480 V. Both deliver low loss, low noise, and reliable outdoor performance.Custom configurations can be provided for your project demands.
SKU: ATO-DT-STPM
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-20 days

Note: Capacity, primary voltage, secondary voltage, and certification requirements are customizable. Please contact us for more details and pricing.

Available in single-phase and three-phase configurations, ATO pad mounted distribution transformers combine a compact sealed design, low-loss efficiency, quiet operation, flexible distribution options, and comprehensive protection features. With capacities from 25 kVA to 2500 kVA, they provide safe, reliable, and cost-effective power distribution for utility, commercial, and industrial applications. Customize your distribution transformer right now.

Technical Specifications

Single phase pad mounted distribution transformer

Single phase pad mounted distribution transformer size

Typical Dimensions and Weights (C.R.G.O Core)

Rating (kVA)HV (kV)Tap (%)LV (V)Loss (W)Dimension (mm)Weight (kg)
No LoadFull LoadABCOil WeightTotal Weight
257.62±2*2.5%120–240115420680830950175405
37.5130520700850980190423
501506607308751000205459
751909808008951030245557
10024512308409501105317697
16738015609109901185389925
2505502000975109012154621215
2519.92±2*2.5%120–240115420680830950175405
37.5130520700850980190423
501506607308751000204464
751909808008951030243562
10024512308409501105311694
16738015609109901185386930
2505502000975109012154621215

Note: The above date is only subject to our standard design, special reqirement can be customized.
3 Phase Pad Mounted Distribution Transformer

3 phase pad mounted distribution transformer dimension
Typical Dimensions and Weights (C.R.G.O Core)

Rating (kVA)HV (kV)Taps (%)LV (V)Loss (W)Dimension (mm)Weight (kg)
No LoadFull LoadABCOil WeightTotal Weight
7512.47±2*2.5%480/277
208/120
2401230148015501575180700
112.53201730153015601585205905
15041022301550156515952201005
22542031501660158516002401295
30068038501680160016003001505
50098053801690160516003502003
75099076001735170016506052791
10001180105001800170016506603335
15001680150001800170017307804250
20002000192001850175017308804630
250025502580018501750180015004950

Note: The above date is only subject to our standard design, special reqirement can be customized.

Applications

ATO pad mounted distribution transformers serve residential neighborhoods, commercial developments, industrial facilities, utility networks, and rural agricultural areas, delivering reliable, weather-resistant power distribution across diverse outdoor environments.

Pad mounted distribution transformer applications

Tips: How is a pad mounted transformer different from a conventional transformer?

A pad mounted distribution Transformer is a ground-mounted, fully enclosed electrical transformer designed for underground distribution systems. It is typically installed on a concrete pad and used in residential, commercial, and industrial power networks to step down medium voltage to usable low voltage levels.
Compared with conventional transformers (such as pole-mounted or open-type oil-immersed transformers), a pad mounted transformer has several key differences. It features a sealed metal enclosure, which protects all live components and eliminates direct exposure, making it much safer for installation in public or accessible areas. It also uses underground cable connections instead of overhead lines, resulting in a cleaner and more compact power distribution layout.
In addition, pad mounted transformers offer enhanced safety, lower noise levels, and improved environmental protection, while conventional transformers are often more exposed and require higher installation clearance. As a result, pad mounted units are widely used in urban distribution networks where safety, aesthetics, and reliability are critical.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Note: Capacity, primary voltage, secondary voltage, and certification requirements are customizable. Please contact us for more details and pricing.

Available in single-phase and three-phase configurations, ATO pad mounted distribution transformers combine a compact sealed design, low-loss efficiency, quiet operation, flexible distribution options, and comprehensive protection features. With capacities from 25 kVA to 2500 kVA, they provide safe, reliable, and cost-effective power distribution for utility, commercial, and industrial applications. Customize your distribution transformer right now.

Technical Specifications

Single phase pad mounted distribution transformer

Single phase pad mounted distribution transformer size

Typical Dimensions and Weights (C.R.G.O Core)

Rating (kVA)HV (kV)Tap (%)LV (V)Loss (W)Dimension (mm)Weight (kg)
No LoadFull LoadABCOil WeightTotal Weight
257.62±2*2.5%120–240115420680830950175405
37.5130520700850980190423
501506607308751000205459
751909808008951030245557
10024512308409501105317697
16738015609109901185389925
2505502000975109012154621215
2519.92±2*2.5%120–240115420680830950175405
37.5130520700850980190423
501506607308751000204464
751909808008951030243562
10024512308409501105311694
16738015609109901185386930
2505502000975109012154621215

Note: The above date is only subject to our standard design, special reqirement can be customized.
3 Phase Pad Mounted Distribution Transformer

3 phase pad mounted distribution transformer dimension
Typical Dimensions and Weights (C.R.G.O Core)

Rating (kVA)HV (kV)Taps (%)LV (V)Loss (W)Dimension (mm)Weight (kg)
No LoadFull LoadABCOil WeightTotal Weight
7512.47±2*2.5%480/277
208/120
2401230148015501575180700
112.53201730153015601585205905
15041022301550156515952201005
22542031501660158516002401295
30068038501680160016003001505
50098053801690160516003502003
75099076001735170016506052791
10001180105001800170016506603335
15001680150001800170017307804250
20002000192001850175017308804630
250025502580018501750180015004950

Note: The above date is only subject to our standard design, special reqirement can be customized.

Applications

ATO pad mounted distribution transformers serve residential neighborhoods, commercial developments, industrial facilities, utility networks, and rural agricultural areas, delivering reliable, weather-resistant power distribution across diverse outdoor environments.

Pad mounted distribution transformer applications

Tips: How is a pad mounted transformer different from a conventional transformer?

A pad mounted distribution Transformer is a ground-mounted, fully enclosed electrical transformer designed for underground distribution systems. It is typically installed on a concrete pad and used in residential, commercial, and industrial power networks to step down medium voltage to usable low voltage levels.
Compared with conventional transformers (such as pole-mounted or open-type oil-immersed transformers), a pad mounted transformer has several key differences. It features a sealed metal enclosure, which protects all live components and eliminates direct exposure, making it much safer for installation in public or accessible areas. It also uses underground cable connections instead of overhead lines, resulting in a cleaner and more compact power distribution layout.
In addition, pad mounted transformers offer enhanced safety, lower noise levels, and improved environmental protection, while conventional transformers are often more exposed and require higher installation clearance. As a result, pad mounted units are widely used in urban distribution networks where safety, aesthetics, and reliability are critical.