Specification

BasicsModelATO280-3004A
Matched Driver ModelATODSP86(Click it to see more info)
Holding torque4.4Nm
Current/phase3A
Resistance1.5Ω
Step angle1.8°
Rotor inertia1600g.cm²
Weight2.4kg
Length80mm
Motor leads4
Technical parametersStep Angle Accuracy±5%(full step, no load)
Resistance Accuracy±10%
Inductance Accuracy±20%
Temperature Rise80℃ Max.(rated current, 2 phase on)
Ambient Temperature-10℃~+ 50℃
Insulation Resistance100MΩ Min 500V DC
Dielectric Strength500V AC for one minute
Shaft Radial Play0.06Max.(450g)
Shaft Axial Play0.08Max.(450g)

Dimensions

stepper motor dimension L60-120

Motor Connection

/Motor connection

Details

Nema 34 Stepper Motor,1.1A-8A Details

Tips: What is closed-loop stepper motor?

Closed-loop stepper motor indicates the combination of stepper motor and closed-loop control. Due to the shortcomings of open-loop control system of stepper motor, like low accuracy and out of step, the closed-loop control system of stepper motor can be applied into the occasions with high precision. Such control mode indicates directly or indirectly detecting the location or velocity to devolve (or load) and automatically giving out the drive pulse sequence of stepper motor through feedback and proper handling. As for this drive pulse sequence, there are many methods for realizing such changing control mode according to the location of load or rotor. High requirement for location precision can be realized on occasion with high precision requirement by combining micro-step drive technology and microcomputer control technique.

How to control a stepper motor using a PLC and HMI?
This video shows you how to configure a PLC, HMI, motor driver, and proximity sensor to perform Origin Return (OPR) control of a stepper motor.

Common Stepper Motor Troubleshooting Problems and Tips
In this video, 9 common problems that can occur with stepper motors are discussed, and expert advice is provided for diagnosing and effectively resolving these problems. If you have ever experienced problems with your stepper motor or want to be prepared for any future problems, this video is a must watch.

Controlling Stepper Motors with HMI and PLC for Fixed Cycle Power Delivery
In this video, we explore the step-by-step process of configuring an HMI and PLC to synchronize and manage specific cycle lengths of stepper motors, ensuring accurate power delivery.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

In the case of non-overload, the speed and stop position of the motor only depend on the frequency and pulse number of the pulse signal, and are not affected by the load change. That is, when a pulse signal is added to the motor, the motor rotates through a step angle. The existence of this linear relationship, coupled with the characteristics of the stepper motor having only periodic errors and no cumulative errors. This makes it very simple to use stepper motors to control the speed, position and other control fields.

Product reviews
Could your DSP42 stepper motor drive control a NEMA 8 stepper?
5
Tristram
Avatar
8/2/2021 1:31 AM
Could your DSP42 stepper motor drive control a NEMA 8 stepper?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this DSP42 controller can be used for NEMA 11, 14, 17 stepper motor, so it can be used for NEMA 8 motor, but it would be better to send us your specific parameters of NEMA 8 motor for more confirmation.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Nema 34 Stepper motor with high torque, 4.4Nm in 80mm, 1.8 degree, 2 phase and 4 wires, manufacturer direct sale.

Specification

BasicsModelATO280-3004A
Matched Driver ModelATODSP86(Click it to see more info)
Holding torque4.4Nm
Current/phase3A
Resistance1.5Ω
Step angle1.8°
Rotor inertia1600g.cm²
Weight2.4kg
Length80mm
Motor leads4
Technical parametersStep Angle Accuracy±5%(full step, no load)
Resistance Accuracy±10%
Inductance Accuracy±20%
Temperature Rise80℃ Max.(rated current, 2 phase on)
Ambient Temperature-10℃~+ 50℃
Insulation Resistance100MΩ Min 500V DC
Dielectric Strength500V AC for one minute
Shaft Radial Play0.06Max.(450g)
Shaft Axial Play0.08Max.(450g)

Dimensions

stepper motor dimension L60-120

Motor Connection

/Motor connection

Details

Nema 34 Stepper Motor,1.1A-8A Details

Tips: What is closed-loop stepper motor?

Closed-loop stepper motor indicates the combination of stepper motor and closed-loop control. Due to the shortcomings of open-loop control system of stepper motor, like low accuracy and out of step, the closed-loop control system of stepper motor can be applied into the occasions with high precision. Such control mode indicates directly or indirectly detecting the location or velocity to devolve (or load) and automatically giving out the drive pulse sequence of stepper motor through feedback and proper handling. As for this drive pulse sequence, there are many methods for realizing such changing control mode according to the location of load or rotor. High requirement for location precision can be realized on occasion with high precision requirement by combining micro-step drive technology and microcomputer control technique.

Product reviews
Could your DSP42 stepper motor drive control a NEMA 8 stepper?
5
Tristram
Avatar
8/2/2021 1:31 AM
Could your DSP42 stepper motor drive control a NEMA 8 stepper?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this DSP42 controller can be used for NEMA 11, 14, 17 stepper motor, so it can be used for NEMA 8 motor, but it would be better to send us your specific parameters of NEMA 8 motor for more confirmation.
Only registered users can write reviews