Micro Differential Pressure Transmitter with Display, Wall-mounted/Embedded

$143.58
Micro differential pressure transmitter combines an LCD display, RS485 communication and IP65 protection, with wall-mounted or embedded installation options. Built-in buzzer and audible/visual alarm functions make it suitable for low differential pressure monitoring and alarm applications.
SKU: ATO-PRES-CCY81
*
Free Shipping
Delivery date: 6-12 days

The wall-mounted/embedded micro differential pressure transmitter is suitable for positive pressure, negative pressure or differential pressure gas pressure measurement of various ventilation and air-conditioning systems and equipment, with relay switch control and sound and light alarm. Both wall-mounted and embedded installation are possible. In addition, we can also provide customized products that meet the application needs of customers. If needed, please feel free to contact us.

Features

  • Micro differential pressure transmitter has the default configuration where the low-pressure side is connected to the front panel and the high-pressure side to the side panel. For other requirements, please contact us.
  • It has a built-in buzzer that provides both audible and visual alarms, with the ability to set the alarm pressure range on-site.
  • The micro differential pressure transmitter uses imported components, offering low temperature drift and high stability to ensure long-term, reliable operation.
  • The transmitter supports both wall-mounted and embedded installations, meeting the needs of various on-site applications.
  • Its housing is made of flame-retardant ABS material, offering excellent impact resistance, heat resistance, and other outstanding properties.

Specification

ModelATO-CCY81
Measuring mediumair and neutral gas (compatible with contact material and humidity <90RH%, no condensation)
Measuring range0~10kPa (optional, please contact us if other ranges are required)
Accuracy0.5%FS or 0.25%FS (range ≥1kPa)
1%FS or 0.5%FS (range <1kPa)
Pressure typedifferential pressure
Output signalRS485
Alarm outputrelay output *2 (contact capacity 220VAC, 3A)
Power supply voltage15~28VDC
Temperature compensation-10~60℃
Medium temperature-10~60℃
Connection time400ms
Response frequency≤5Hz
Stability performance±0.3%FS/year (range ≥1kPa)
±0.5%FS/year (range ≤1kPa)
Temperature drift±0.03%FS/℃ (within temperature compensation range)
Durability1x106 times (number of cycles from lower limit to upper limit of range)
Overall weightabout 365g
Protection levelIP65
Resolution1/2000
Maximum power≤0.015Us (W)
Insulation resistance≥100MΩ, 500VDC
Insulation strength500VAC
Environmental temperature-40~85℃
Environmental humidity0%~95%RH (no condensation and no condensation)
CertificationCE, ISO 9001, SGS


Dimension (mm)

Micro differential pressure transmitter dimension

Wiring Instructions

TypeColorDescription
Four-core signal line
red
Power+
yellow
485A
blue
Power-
white
485B
Six-core control line
red
Normally open contact  N/O
black 
Common  COM
white
Normally closed contact  NC
brown 
Normally open contact  N/O
green 
Common  COM
yellow
Normally closed contact  NC

Tips: Applications of micro differential pressure transmitter

  • Industrial equipment: Used for differential pressure monitoring in various industrial equipment, such as compressors, pumps, filters, etc., ensuring optimal performance and maintenance of the equipment.
  • Environmental monitoring: Applied for monitoring differential pressure in indoor and outdoor environments, including commercial buildings, residential buildings, weather monitoring, smart homes, hospital rooms, clean rooms, and more, to help maintain air quality and suitable environmental conditions.
  • Pharmaceutical and biotechnology: Widely used in the pharmaceutical industry, life sciences, and biotechnology processes, including applications like pharmaceutical water, cleanroom control, disinfection and drying processes, disinfectant water, and more, ensuring product quality and the safety of the production environment.
  • Cleanrooms and laboratories: Used for differential pressure monitoring in cleanrooms and laboratories to ensure proper airflow and cleanliness levels meet industry standards, safeguarding the accuracy and safety of experiments and production processes.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent

In this video, ATO will show you top ten most used sensors (sensing technologies).

*
*
*
*

The wall-mounted/embedded micro differential pressure transmitter is suitable for positive pressure, negative pressure or differential pressure gas pressure measurement of various ventilation and air-conditioning systems and equipment, with relay switch control and sound and light alarm. Both wall-mounted and embedded installation are possible. In addition, we can also provide customized products that meet the application needs of customers. If needed, please feel free to contact us.

Features

  • Micro differential pressure transmitter has the default configuration where the low-pressure side is connected to the front panel and the high-pressure side to the side panel. For other requirements, please contact us.
  • It has a built-in buzzer that provides both audible and visual alarms, with the ability to set the alarm pressure range on-site.
  • The micro differential pressure transmitter uses imported components, offering low temperature drift and high stability to ensure long-term, reliable operation.
  • The transmitter supports both wall-mounted and embedded installations, meeting the needs of various on-site applications.
  • Its housing is made of flame-retardant ABS material, offering excellent impact resistance, heat resistance, and other outstanding properties.

Specification

ModelATO-CCY81
Measuring mediumair and neutral gas (compatible with contact material and humidity <90RH%, no condensation)
Measuring range0~10kPa (optional, please contact us if other ranges are required)
Accuracy0.5%FS or 0.25%FS (range ≥1kPa)
1%FS or 0.5%FS (range <1kPa)
Pressure typedifferential pressure
Output signalRS485
Alarm outputrelay output *2 (contact capacity 220VAC, 3A)
Power supply voltage15~28VDC
Temperature compensation-10~60℃
Medium temperature-10~60℃
Connection time400ms
Response frequency≤5Hz
Stability performance±0.3%FS/year (range ≥1kPa)
±0.5%FS/year (range ≤1kPa)
Temperature drift±0.03%FS/℃ (within temperature compensation range)
Durability1x106 times (number of cycles from lower limit to upper limit of range)
Overall weightabout 365g
Protection levelIP65
Resolution1/2000
Maximum power≤0.015Us (W)
Insulation resistance≥100MΩ, 500VDC
Insulation strength500VAC
Environmental temperature-40~85℃
Environmental humidity0%~95%RH (no condensation and no condensation)
CertificationCE, ISO 9001, SGS


Dimension (mm)

Micro differential pressure transmitter dimension

Wiring Instructions

TypeColorDescription
Four-core signal line
red
Power+
yellow
485A
blue
Power-
white
485B
Six-core control line
red
Normally open contact  N/O
black 
Common  COM
white
Normally closed contact  NC
brown 
Normally open contact  N/O
green 
Common  COM
yellow
Normally closed contact  NC

Tips: Applications of micro differential pressure transmitter

  • Industrial equipment: Used for differential pressure monitoring in various industrial equipment, such as compressors, pumps, filters, etc., ensuring optimal performance and maintenance of the equipment.
  • Environmental monitoring: Applied for monitoring differential pressure in indoor and outdoor environments, including commercial buildings, residential buildings, weather monitoring, smart homes, hospital rooms, clean rooms, and more, to help maintain air quality and suitable environmental conditions.
  • Pharmaceutical and biotechnology: Widely used in the pharmaceutical industry, life sciences, and biotechnology processes, including applications like pharmaceutical water, cleanroom control, disinfection and drying processes, disinfectant water, and more, ensuring product quality and the safety of the production environment.
  • Cleanrooms and laboratories: Used for differential pressure monitoring in cleanrooms and laboratories to ensure proper airflow and cleanliness levels meet industry standards, safeguarding the accuracy and safety of experiments and production processes.